EN 12619-2013 en Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method《固定污染源排放 决心总气体质量.pdf
《EN 12619-2013 en Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method《固定污染源排放 决心总气体质量.pdf》由会员分享,可在线阅读,更多相关《EN 12619-2013 en Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method《固定污染源排放 决心总气体质量.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 12619:2013Stationary source emissions Determination of the massconcentration of total gaseousorganic carbon Continuousflame ionisation detectormethodBS EN 12619:2013 BRITIS
2、H STANDARDNational forewordThis British Standard is the UK implementation of EN 12619:2013.It supersedes BS EN 12619:1999 and BS EN 13526:2002 which arewithdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee EH/2/1, Stationary source emission.A list of organizations rep
3、resented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2013. Published by BSI StandardsLimited 2013ISBN 978 0 580
4、 73805 0ICS 13.040.40Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 January 2013.Amendments issued since publicationDate T e x t a f f e c t e dBS EN 12619:201
5、3EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 12619 January 2013 ICS 13.040.40 Supersedes EN 12619:1999, EN 13526:2001English Version Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method Emissions
6、de sources fixes - Dtermination de la concentration massique en carbone organique total - Mthode du dtecteur continu ionisation de flamme Emissionen aus stationren Quellen - Bestimmung der Massenkonzentration des gesamten gasfrmigen organisch gebundenen Kohlenstoffs - Kontinuierliches Verfahren mit
7、dem Flammenionisationsdetektor This European Standard was approved by CEN on 24 November 2012. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-da
8、te lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
9、 under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, For
10、mer Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT
11、 EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 12619:2013: EBS EN 12619:2013EN 12619:2013 (E) 2 Contents Page Forew
12、ord . 3 1 Scope 4 2 Normative references . 4 3 Terms and definitions 4 4 The principle of the technique 6 5 Requirements for apparatus and gases 7 6 Measurement procedure 9 Annex A (normative) Determination of the performance characteristics of a FID . 12 Annex B (informative) Basic functionality of
13、 an FID 15 Annex C (informative) Measurement uncertainty and associated statistics 18 Annex D (informative) Safety measures . 20 Annex E (informative) Significant technical changes 21 Bibliography 22 BS EN 12619:2013EN 12619:2013 (E) 3 Foreword This document (EN 12619:2013) has been prepared by Tech
14、nical Committee CEN/TC 264 “Air quality”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by July 2013, and conflicting national standards shall be withdrawn
15、at the latest by July 2013. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 12619:1999 and EN 13526:2001.
16、The list of the most significant technical changes that have been made in this new edition is to be found in Annex E. According to the CEN/CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bu
17、lgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
18、Turkey and the United Kingdom. BS EN 12619:2013EN 12619:2013 (E) 4 1 Scope This European Standard specifies a flame ionisation detector (FID) method. It is intended for use as a standard reference method for the measurement of the mass concentration of gaseous and vaporous organic substances (expres
19、sed as TVOC) in stationary source emissions (e.g. emissions from waste incinerators and solvent using processes, emission measurements according to 2010/75/EU) in the concentration range up to 1 000 mg/m. This European Standard specifies the requirements for an instrument using flame ionisation dete
20、ction, together with procedures for its operation. The results obtained using this standard are expressed in milligrams per cubic metre (mg/m) as total carbon (TVOC). This European Standard is not applicable for permanently installed automated measuring systems (AMS). Alternative methods to this met
21、hod may be used provided that the user can demonstrate equivalence, based on the principles of CEN/TS 14793. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edit
22、ion cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 15259, Air quality Measurement of stationary source emissions Requirements for measurement sections and sites and for the measurement objective, plan and report EN 15267-1,
23、 Air quality Certification of automated measuring systems Part 1: General principles EN 15267-2, Air quality Certification of automated measuring systems Part 2: Initial assessment of the AMS manufacturers quality management system and post certification surveillance for the manufacturing process EN
24、 15267-3:2007, Air quality Certification of automated measuring systems Part 3: Performance criteria and test procedures for automated measuring systems for monitoring emissions from stationary sources EN ISO 9169, Air quality Definition and determination of performance characteristics of an automat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN126192013ENSTATIONARYSOURCEEMISSIONSDETERMINATIONOFTHEMASSCONCENTRATIONOFTOTALGASEOUSORGANICCARBONCONTINUOUSFLAMEIONISATIONDETECTORMETHOD

链接地址:http://www.mydoc123.com/p-706539.html