EIA TIA-455-12A-1989 FOTP-12 Fluid Immersion Test for Fiber Optic Components Replaces 455-40-83《FOTP-12 光器件的流体浸泡试验》.pdf
《EIA TIA-455-12A-1989 FOTP-12 Fluid Immersion Test for Fiber Optic Components Replaces 455-40-83《FOTP-12 光器件的流体浸泡试验》.pdf》由会员分享,可在线阅读,更多相关《EIA TIA-455-12A-1989 FOTP-12 Fluid Immersion Test for Fiber Optic Components Replaces 455-40-83《FOTP-12 光器件的流体浸泡试验》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、3.; EIA TIA-455-12A 9 m 3234b00 0009104 2 m +- I u) u) tf I d I- d w I d AMERKAN L- STANDAAD AN8V EIA/ TIA-466-12A-I8O APPROVED August 24, 1989 EIA/TIA STANDARD FOTP-12 Fluid Immersion Test for Fiber Optic Components OCTOBER 1989 ELECTRONIC INDUSTRIES ASSOCIATION ENGINEERING DEPARTMENT TEfEFf INDUST
2、RY ASSOCIATION Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-EIA TIA-455-12A 7 m 3234600 0007105 4 m NOTICE EIA/TIA Engineering Standards and Publications are designed to serv
3、e the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Stand
4、ards and Publications shall not in any respect preclude any member or nonmember of EIA/TIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than EIA/TIA mem
5、bers, whether the standard is to be used either domestically or internationally. . Recommended Standards and Publications are adopted by EIA/TIA without regard to whether or not their adoption may involve patents on articles, materials, or processes. By such action, EIA/TIA does not assume any liabi
6、lity to any patent owner, nor does it assume any obligation whatever to parties adopting the Recommended Standard or Publication. This EIA/TIA Standard is considered to have International Standardization implication, but the International Electrotechnical Commission activity has not progressed to th
7、e point where a valid comparison between the EIA/TIA Standard and the IEC document can be made. a This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish approp
8、riate safety and health practices and to determine the applicability of regulatory limitations before its use. Copyright 1989 Published by ELECTRON IC IN DUSTRI ES ASSOCIATION Engineering Department 2001 Pennsylvania Ave, N.W. Washington, D.C. 20006 (Temporary Headquarters 1722 Eye St., N.W. Washing
9、ton, D.C. 20006) oTelecommunications Industry Association PRICE: $1 0.00 All rights reserved Printed in U.S.A. Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-EIA TIA-455-12A 9
10、3234600 0009106 b = EIA/TIA-455-12A Page 1 FOTP- 12 FLUID IMMERSION TEST FOR FIBER OPTIC COMPONENTS (From EIA Standards Proposal No. 1790-A, formulated under the cognizance of TIA FO-6.3, Subcommittee on Fiber Optic Interconnecting Devices, TIA FO-6.4, Subcommittee on Fiber Optic Test Methods and In
11、strumentation, and TIA FO-6.7, Subcommittee on Fiber Optic Cables.) This FOTP is part of the series of test procedures included within Recommended Standard EIA/TIA-455. NOTE : This FOTP was originally published in Recommended Standard RS-455-4 as FOTP-12. This FOTP also supersedes FOTP-40, previousl
12、y published in EIA Recommended Standard RS-455-40 as FOTP-40. 1.0 INTENT 1.1 The intent of this test is to establish the ability of a fiber optic component (cable, connecting device, etc. ) to resist degradation when exposed to specific fluids with which the- component may come into contact during i
13、ts service life. (Note: For fluid immersion testing of optical fiber, refer to FOTP-75.) 1.2 Potential failure modes for this test include, but are not limited to: 1.2.1 Swelling of any materials. (Exception - materials that are functionally designed to swell, e.g., .swellable water blocking tapes.)
14、 1.2.2 Dimension changes other than swelling. 1.2.3 Softening of any materials. 1.2.4 Loss of seal or adhesive bonding between two bonded surfaces. 1.2.5 Discoloration of materials, finishes and marking 1.2.6 Changes in mating and/or coupling (may or may not be considered detrimental). characteristi
15、cs. Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-EIA/TIA-455-12A Page 2 1.2.7 Corrosion of any materials, finish peeling, cracking or flaking. 1.2.8 Inability to mate or unma
16、te (connector, device or cable assembly). 1.2.9 Degradation of cable/connector optical transmission characteristics. 2.0 REFERENCED DOCUMENTS Test or inspection requirements may include, but are not limited to, the following references: 2.1 ASTM Documents ASTM D 56 “Test Method For Flash Point by Ta
17、g Closed Tester“ 2.2 EIA/TIA Documents FOTP-13 (EIA-455-13) “Visual and Mechanical Inspection of Fiber, Cables, .Connectors and/or Other Fiber Optic Devices“ FOTP-20 (EIA-455-20) “Measurement of Change in Optical Transmit tance FOTP-75 (EIA-455-75) “Fluid Immersion Test For Optical 2.3 Federal and M
18、ilitary Specifications Waveguide Fibers“ 1 TT-I -7 3 5 “Isopropyl Alcohol“ MIL-G-3056 MIL-H-5606 MIL-T-5624 MIL-F-16884 “Gasoline, Automotive, Combat“ “Hydraulic Fluid, Petroleum Base, Aircraft, Missile, and Ordnance“ “Turbine Fuel, Aviation, Grades JP-4 and JP-5 “Fuel, Naval Distillatef1 Available
19、from Naval Publications and Forms Center, 5801 Tabor Avenue, Philadelphia, PA 19120-5099, or from the procuring activity, or as directed by the contracting officer. a fi- . Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networ
20、king permitted without license from IHS-,-,-EIA TIA-455-12A 89 3234600 O009108 T W EIA/TIA-455-12A Page 3 MIL-L-17331 MIL-H-17672 MIL-L-23699 MIL-L-24467 3.0 TEST EQUIPMENT IILubricating Oil, Steam Turbine, Vapor-Space Inhibited“ IHydr aulic Fluid, Petroleum, Inhibitedv1 “Lubricating Oil, Aircraft T
21、urbine Engines, Synthetic Gas “Lubricating Oil, Steam Turbine and Gear, Moderate Service“ 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 PyrexTM or stainless steel vessels of s itable volume, one for each test fluid. Vessels shall be of sufficient size and fluid capacity to permit the sample(s) under test to be ap
22、propriately immersed (complete immersion, in many instances) in each fluid selected, without violating other physical constraints (e.g., minimum cable bending radius). Prepared immersion fluids. Unless otherwise specified, test fluids to be used shall be those listed in Tables 1 or II for all tests
23、except for U.S. Military applications; for U.S. Military applications only, test fluids to be used shall be those listed in Table III. Immersion Thermometer, O to 200 OC range. Table stove, hot plate, circulating air oven or other suitable heat source, capable of attaining the specified temperatures
24、 and of maintaining temperatures within f 2C of the required setting. Timer. Micrometer caliper. Analytical balance. Optical transmittance change measurement apparatus as described in FOTP-20. TM Pyrex is a trademark of Corning Glass Works. Copyright Telecommunications Industry Association Provided
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EIATIA45512A1989FOTP12FLUIDIMMERSIONTESTFORFIBEROPTICCOMPONENTSREPLACES4554083FOTP12 器件 流体 浸泡 试验 PDF

链接地址:http://www.mydoc123.com/p-705047.html