ECMA 109-2012 Declared Noise Emission Values of Information Technology and Telecommunications Equipment (6th Edition).pdf
《ECMA 109-2012 Declared Noise Emission Values of Information Technology and Telecommunications Equipment (6th Edition).pdf》由会员分享,可在线阅读,更多相关《ECMA 109-2012 Declared Noise Emission Values of Information Technology and Telecommunications Equipment (6th Edition).pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、 Reference number ECMA-123:2009 Ecma International 2009 ECMA-109 6th Edition / December 2012 Declared Noise Emission Values of Information Technology and Telecommunications Equipment COPYRIGHT PROTECTED DOCUMENT Ecma International 2012 Ecma International 2012 i Contents Page 1 Scope 1 2 Normative re
2、ferences 2 3 Terms and definitions . 2 4 Conformance requirements 5 4.1 For declaration . 5 4.2 For verification . 5 5 Determination of the noise emission values to declare 5 5.1 General . 5 5.2 Determination of the sample mean A-weighted sound power level, AWL in decibels 5 5.3 Determination of the
3、 mean A-weighted sound power level, LWA,m in bels . 6 5.4 Determination of the mean A-weighted emission sound pressure level, LpA,m in decibels 6 5.5 Determination of the value to declare for the statistical adder for verification, Kv in bels 6 6 Presentation of declared noise emission values . 6 6.
4、1 Required information 6 6.2 Additional information 7 7 Verification of the statistical upper limit A-weighted sound power level, LWA,c 7 7.1 General . 7 7.2 Verification of LWA,c for a batch of equipment . 7 Annex A (normative) Procedure for determining the statistical adder for verification, Kv 9
5、Annex B (informative) Examples of noise emission declarations . 13 Annex C (informative) Character of noise 15 ii Ecma International 2012 Ecma International 2012 iii Introduction Information on acoustic noise emission of information technology and telecommunications equipment is needed by users, pla
6、nners, manufacturers and authorities. This information is required for comparison of the noise emissions from different products and for installation acoustics planning and may be used for relating to workplace noise immission requirements. In order for equipment noise emission data to be useful, un
7、iform methods are necessary for the following purposes: Measurement of noise emission values ECMA-74 specifies procedures for measuring sound power level based on ISO 37411, ISO 37442 and ISO 37453 (reverberation test room or hemi-anechoic room) and emission sound pressure level based on ISO 112015.
8、 Determination of the noise emission values to be declared ISO 4871 gives guidelines for the preparation of standards for deriving noise emission values for declaration purposes, and the ISO 7574 series gives statistical methods for such determination. ECMA-109 is based upon these basic Internationa
9、l Standards. Presentation of declared noise emission values For the presentation of declared noise emission values, it is of prime importance to declare A-weighted sound power levels, LWA. It is recognized, however, that users still desire information on A-weighted emission sound pressure levels, Lp
10、A. Therefore, this Ecma Standard specifies that both quantities shall be declared. In the preparation of this Ecma Standard divergences of opinion have been found between various national and international organisations as to the most useful way of presenting noise emission values. In order to avoid
11、 any misunderstanding between presentation of sound power levels in decibels re 1 pW and emission sound pressure levels in decibels re 20 Pa, this Ecma Standard expresses sound power level values to be declared in bels and emission sound pressure level values in decibels, to alleviate the divergence
12、s of opinion mentioned. As an option, methods for determination and presentation of subjective characteristics of noise emission are presented in annex C. Verification of declared noise emission values ISO 7574-4 gives methods for the verification of a declared noise emission value. In this Ecma Sta
13、ndard the procedure is restricted to verifying the statistical upper limit A-weighted sound power level, LWA,c only. The reasons for using bels for declared A-weighted sound power levels are: i) To avoid user confusion In this Ecma Standard the A-weighted sound power level is the primary descriptor
14、and will be reported in accordance with ISO 4871. Many manufacturers and users of information technology and telecommunications equipment have historically used A-weighted emission sound pressure levels in decibels. Since customers want both sound power and emission sound pressure levels, this Ecma
15、Standard utilises both quantities. Without including reference values (i.e. 1 pW and 20 Pa), expressing both declared sound power levels and declared emission sound pressure levels in decibels tends to cause confusion. To distinguish the two, this Ecma Standard expresses declared sound power level i
16、v Ecma International 2012 values in bels, where a bel is 10 decibels re 1pW, and expresses emission sound pressure level values in decibels re 20 Pa. ii) To avoid misapplication of data If declared A-weighted sound power levels were expressed in decibels, users may mistakenly compare the sound power
17、 levels with workplace regulations of immission sound pressure levels. In many information technology and telecommunications equipment applications, the sound power level (in decibels) value of the equipment is significantly larger than the immission sound pressure level (in decibels) value measurab
18、le in the workplace. The later, immission value is the level at human ear location in a given environment which changes with the acoustic environment, such as room size, acoustical attenuation property of floor, wall, ceiling, doors, windows and room partitions, etc. while the sound power level valu
19、e is an intrinsic property of equipment that does not change with the environment it is placed in. iii) To promote the use of ECMA-109 The purpose of ECMA-109 is to provide uniform methods of presenting declared noise emission values to users. Without using bels, this objective would be lost since t
20、here would be an incentive for some manufacturers to report emission sound pressure levels instead of sound power levels. The primary descriptor of information technology and telecommunications equipment noise is the declared mean A-weighted sound power level, LWA,m. If ECMA-109 were to use decibels
21、 for declared A-weighted sound power levels, manufacturers who do not implement this Ecma Standard would be at a competitive advantage by reporting emission sound pressure levels in decibels which would be lower than the declared sound power levels also in decibels. Not only would the user be confus
22、ed, and unable to tell the difference, but the manufacturer who followed ECMA-109 would be at an unfair competitive disadvantage. To eliminate this confusion and disadvantage and to promote the uniform reporting of declared noise emission values, the declared A-weighted sound power levels must be re
23、ported in bels. iv) To use a method based on successful experience For several years, many international companies, members of Ecma, have reported A-weighted sound power levels in bels and A-weighted emission sound pressure levels in decibels without confusion of their customers. Indeed, their custo
24、mers have been able to distinguish easily between the important difference of sound power level and emission sound pressure level, and the users have not lost the significance of the digit after the decimal mark. Actually they have been less confused: without using bels, they would wonder: “which de
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便