1、I v) a w I- f - EIA TEPL05-15 88 3234600 O007356 8 M - - TEPAC PU B L ICAT ION CRT Screen and Glass Ageing Procedures TEP10545 OCTOBER 1988 ELECTRONIC INDUSTRIES ASSOCIATION ENGINEERING DEPARTMENT EIA TEPL05-15 88 3234600 0007357 T .A NOTICE EIA Engineering Standards and Publications are designed to
2、 serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such
3、Standards and Pub- lications shall not in any respect preclude any member or non-member of EIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than EJA mem
4、bers, whether the standard is to be used either domestically or internationally. Recommended Standards and Publications are adopted by EIA without regard to whether or not their adoption may involve patents on articles, materials? or processes. By such action, EIA does not assume any liability to an
5、y patent owner, nor does it assume any obligation whatever to parties adopting the Recom- mended Standard or Publication. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Stan
6、dard to establish appropriate safety and health practices and to determine the applicability of regu- latory limitations before its use. Copyright 1988 Published by s ELECTRONIC INDUSTRIES ASSOCIATION Engineering Department 2001 Eye Street, N.W. Washington, D.C. 20006 PRICE: $10.00 Published in U.S.
7、A. - EIA TEPL05-15 88 3234600 0007358 I TEP105-15 CRT SCREEN AND GLASS AGEING PROCEDURES This publication was formulated under the cognizance of the JT-31 Committee on Optical Characteristics of Display Devices and approved by the Tube Engineering Panel Advisory Council (TEPAC). The TEP105 series of
8、 publications comprises a set of test methods developed for industrial cathode ray tubes. They are intended to be useful in evaluating cathode ray tubes with respect to parameters, which are of interest to users of these devices. i EIA TEP105-15 8 m 3234600 0007359 3 m L TEP105-15 CRT Screen and Gla
9、ss Aqeinq Procedures Introduction to the Glass and Screen Aqeinq Procedures This procedure is broken down into three subsections. They are: I. Glass Ageing Thi5 procedure tests the ageing properties of CRT glass alone, independent of screening conditions or phosphors. II. Pre-Ageing This procedure t
10、ests the often rapi.d initial ageing of the complete CRT system. This test may be used alone or as a pre-test before long term ageing. III. Long Term Ageing This procedure tests the long term ageing Properties Of the complete CRT system. If the tube is cut down after the test i5 complete, glass and
11、screen effects may be seperated. Warning; Due to the high powers involved in these tests, there is the possibility of excessive X-ray levels. Suitable X-ray precautions should be taken while the tests are in progress. ii _. EIA TEPL05-15 88 3234600 00073b0 T = TEP10 5-15 Page 1 Glass Aqeinq Procedur
12、e i Discussion: This test is intended to test the ageing characteristics of CRT glass when subjected to high power densities. Power densities sufficient for ageing of the glass to be a signifigant problem are most commonly encountered in projection television, aircraft cockpit displays and similar h
13、igh power density CRTs. The dosage used in step 3 and the wavelengths measured in step 6 may be adjusted to fit the end use of a particular glass type. Since glass ageing is normally more of a problem at short wavelenths than at long wavelengths, glass to be used with blue or UV phosphors should be
14、checked especially carefully. Equipment Required: 1) Glass Transmission Unit 2) CRT Production Equipment 3) CRT Ageing station or chassis Procedure: i. Clean the glass sample according to the currently specified procedure. Do not screen or lacquer the glass. Aluminize the glass according to the curr
15、ently specified procedure. Finish the tube in the normal manner. 2) If you will age at a greater power density than 4mW/cmz, install liquid cooling if needed for the tube type. 3) Age the tube at the normal operating conditions until 4 Coulombs/cm2 has been accumulated. 4) Cut the tube down and remo
16、ve the aluminum from the inside of the face with caustic solution (5-10% NaH). 5) Measure the glass transmission at the specified wavelengths using unaged glass in the transmission unit as the 100% reference value. 6) Record the average transmission and transmission at any specific wavelengths of in
17、terest. A suggested form is attached. 7) Visually inspect the aged area for cloudiness or a “milky“ appearance. If any is visible, the glass is rejectable. Normal glass color after aging is a transparent brown. EIA TEPL05-15 88 m 3234600 00073bL L m TEPIOS-15 Typical Glass Aging Report This Lot of C
18、RT Glass is ACCEPTABLE/REJECTABLE for glass aging. Glass Manufacturer Data Attached (When available) Lat# Maunufacturer Drawing# Type Date Tested Tubes Made By Tube Numbers First Tube: On Aging Off Aging Aging Station Aging Conditions Transmission Measurements Instrument used 448nm Note: These wavel
19、engths are suitable for projection 544nm tube glass, other wave- 610nm suitable for other Comment lengths may be more applications - Note: Cloudy or milky appearance is cause for rejection Second Tube: On Aging Off Aging Aging Station Aging Conditions Transmission Measurements Instrument used 448nm
20、544nm 6lOnm Comment Note: Cloudy or milky appearance is cauce for rejection - EIA TEPLOS-15 8 323i.1600 O007362 3 P TEP105- 15 Page 3 II. Pre-aqeinq Procedure ais cus s ion : This procedure is presented separately from the long term ageing for two reasons. First, this gives a quick test to determine
21、 if tube ageing will be satisfactory. If a tube fails this test, it is almost certain to fail a long term ageing test. Second, if there is rapid initial ageing, it is difficult to measure accurately in a long term ageing rack set up to measure slaw luminance changes. Equipment: 1) 2) Procedure: 2) 3
22、) 4) 5) 6) 7) Test Set A non-contact luminance meter mounted on a tripod capable of measuring a small area on the tube. Example: Tektronix J-16 meter with lo luminance probe. Put the tube into the test set. Install liquid cooling if necessary. Set the tube up with a 3“ x 3“ (76.2 x 76.2mm) unblanked
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECATEP105151988CRTSCREENANDGLASSAGINGPROCEDURESCRT 屏幕 玻璃 老化 程序 PDF

链接地址:http://www.mydoc123.com/p-704580.html