ECA IS-43AC-1988 Cable for LAN Twisted Pair Data Communications - Detail Specification for Type 1 Riser Cable《LAN双绞线数据通信用电缆-1类riser电缆的详细规范》.pdf
《ECA IS-43AC-1988 Cable for LAN Twisted Pair Data Communications - Detail Specification for Type 1 Riser Cable《LAN双绞线数据通信用电缆-1类riser电缆的详细规范》.pdf》由会员分享,可在线阅读,更多相关《ECA IS-43AC-1988 Cable for LAN Twisted Pair Data Communications - Detail Specification for Type 1 Riser Cable《LAN双绞线数据通信用电缆-1类riser电缆的详细规范》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、EIA SPECIFICATION -. Y- -. EIA IS-43AC 88 = 3234bOO 0002439 9 = r 4 - e 41b O Cable For LAN Twisted Pair Data Communications - Detail Specif cation For Type 1, Riser Cable SEPTEMBER 1988 ELECTRONIC INDUSTRIES ASSOCIATION ENGINEERING DEPARTMENT EIA IS-43AC 88 m 3234600 0002440 5 m NOTICE EIA Engineer
2、ing Standards and Publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimlim delay the proper prod
3、ilct for his particular need. Existence of such Standards and Pub- lications shall not in any respect preclude any member or non-member of EIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude
4、 their voluntary use by those other than EIA members, whether the standard is to be used either domestically or internationally. Recommended Standards and Publications are adopted by EIA without regard to whether or not their adoption may involve patents on articles, materials! or processes. By such
5、 action, EIA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the Recom- mended Standard or Publication. Copyright 19 88 Published by ELECTRONIC INDUSTRIES ASSOCIATION Engineering Department 2001 Eye Street, N.W. Washington, D.C. 20006
6、 PRICE: $10.00 Published in U.S.A. T - EIA IS-43AC 88 3234600 0002443 7 I I I I System Standard Organization I Electronic Industries Association I I Detail Specification Number i I NQ-EIA/IS-43AC I I I I I I I I I Omnibus Specification Number: EIA/IS-43 I Blank Detail Specification: I I Electronic C
7、omponents of assessed I quality in accordance with: I I Outline Drawing: I Cross Section i 7 Rip Cord 1 , Conductors (4) NO. 22 AWG Solid Copper (2) DGM Twisted Pair - (4) DGM Conductor insulation Outer Jacket I 1 9.753.25 Riser I Tinned Copper Braided Shield Heat Barrier Tape (Optional) Metal Backe
8、d Tape Separation by Metal Backed Taped I I Type 1 Riser None I I l I ?roduct Description I I I Exchange Cable for use I With Data Processing I Equipment I I Type 1 Riser Cable I I Media (DG.1) Copper . I PVC Jacket I I I Electrical Circuit I Two Insulated Data Grade I Conductor Pairs in a Single 1
9、Typical Construction I I I I Application/Assessment Level I I Assessment Level: C I Performance Grade: I IEEE 802.5 I I I 1 I Information on the availablility of components I I qualified to this specification is given in 1 I the Qualified Products List. I i EIA IS-43AC 00 m 3234600 0002442 9 m NQ-EI
10、A/IS-43AC CONTENTS 1.0 .Scope and Objective . 1 1.1 Scope . 1 1.2 Objective . 1 2.0 General Data . 1 2.1 General 1 1 2.2 Ordering Information . 3.0 Specific Cable Requirements 2 3.1 Configuration . 2 3.1.1 Conductors 2 . 3.1.2 Shields 2 3.1.3 Fillers 2 3.1.4 Rip Cord 2 3.1.5 Jacket 2 3.2 Electrical
11、Specifications . 3 3.2.1 Crosstalk . 3 3.2.2 Impedance . 3 3.2.4 DC Resistance of Conductors . 4 3.3 Cable Mechanical Specifications 4 3.3.1 Mechanical Tests 4 . 3.3.2 Safety Requirements 5 3.3.3 DGM Core Flammability . 5 3.4 Inspection Requirements 5 3.2.3 Attenuation 4 I ii 3 EIA IS-43AC 8 W 32346
12、00 0002443 O W NQ-EIA/I S- 4 3AC Page 1 1.0 SCOPE AND OBJECTIVE 1.1 SCOPE This Detail Specification defines Type 1 Riser cable used with the Token Ring LAN Cabling System. Type 1 R consists of 2 twisted pairs of Data Grade Media (DGM) shielded with aluminum tape and braided shields, all cabled into
13、a single PVC jacketed assembly. The Cabling System is intended to be compatible with IEEE Standard 802.5. It is designed to be used as a total building wiring system. The Cabling System may be used as the communications medium for a Token Ring Network as well as for other data equipment. 1.2 OBJECTI
14、VE The objective of the Detail Specification is to provide a document describing Type 1 R cable as a basis for certification under the KECQ system and for acquisition of conforming cable. 2.0 GENERAL DATA 2.1 GENERAL Cable provided under this Detail Specification shall conform to all general and spe
15、cific requirements applicable to Type 1 R cable in Omnibus Specification EIA/IS-43, Exchange Cable for Use with Data Processing Equipment, and those requirements specified herein. 2.2 ORDERING INFORMATION Orders for cable covered by this Detail Specification shall include the fol lowing information
16、: 1. Identification of cable type 2. Length required 3. Special requirements of reel size or type 4. Other unique requirements not covered in this specification , EIA IS-43AC 8 m 3234600 0002444 2 m NQ-EIA/IS-43AC Page 2 3.0 SPECIFIC CABLE REQUIREMENTS 3.1 CONFIGURATION 3.1.1 CONDUCTORS Cable Type 1
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECAIS43AC1988CABLEFORLANTWISTEDPAIRDATACOMMUNICATIONSDETAILSPECIFICATIONFORTYPE1RISERCABLELAN 双绞线 数据通

链接地址:http://www.mydoc123.com/p-704523.html