ECA EIA-945-2002 Surface Mount Inductor Qualification Specification《表面贴装电感合格规范》.pdf
《ECA EIA-945-2002 Surface Mount Inductor Qualification Specification《表面贴装电感合格规范》.pdf》由会员分享,可在线阅读,更多相关《ECA EIA-945-2002 Surface Mount Inductor Qualification Specification《表面贴装电感合格规范》.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、 EIA STANDARD Surface Mount Inductor Qualification Specification EIA-945 NOVEMBER 2002 ELECTRONIC COMPONENTS, ASSEMBLIES approval levels and sampling plan Test method Inductor inspection Sample size per lot Total sample size Defects permitted 4.2 Electrical characteristics 83 249 0 4.3 Visual and me
2、chanical 5 15 0 4.4 Life test 16 48 4.5.1 Load humidity test 16 48 0 4.5.2 Moisture resistance 16 48 0 4.6 Thermal shock 16 48 0 4.7 Vibration 5 15 4.8 Shock 15 0 4.9 Bending 5 15 4.10 Insulation resistance 5 15 0 4.11 Flammability Present certificate of compliance 4.12 Solderability 10 30 0 4.13 Re
3、sistance to soldering heat 5 15 0 4.14 Terminal Strength 5 15 0 4.2 Electrical characteristics The total samples required in Table 1 shall be measured initially at ambient room temperature, relative humidity, and atmospheric pressure (Typical 25C, 760mm Hg) before subsequent testing. Initial electri
4、cal parameters shall not exceed the values listed in the product specifications. Table 2 Maximum inductance change chart Category L% A 30 B 20 C 15 D 10 E 5 4.3 Visual and mechanical examination Inductors shall be examined visually to verify that no defects in workmanship exist. Mechanical dimension
5、s will be measured and shall meet the requirements defined in the detail specification sheet or reference documents. Unless otherwise specified, when inductors are tested in accordance with the environmental tests listed below and the specification, there shall be no evidence of mechanical damage or
6、 measurable discontinuity. This test may be conducted at room temperature. 4.4 Life test Inductors shall be tested in accordance with MIL-STD-202, Method 108, Test Condition D where applicable except: a) Inductors are to be electrically tested per section 4.3 b) preconditioning is required as specif
7、ied in Section 5. EIA-945 Surface mount inductor qualification specification Page 5 c) test temperature shall be 85 3oC for inductors rated at 85oC , and the test temperature shall be 125oC 3oC for 125oC rated inductors based on a component temperature rise of 20oC. If the component temperature rise
8、 of the device is greater than 20oC, the test temperature shall be adjusted accordingly d) apply maximum rated DC current for 1000 hours minimum e) measurements shall be taken at 0 h and 1000 h; the inductors shall be allowed to stabilize at room temperature for 24 hours before measurements are take
9、n. f) the inductance value shall not change by more than (Refer to 4.2 Maximum Inductance Change Chart Table 2) of the initial value at the intermediate or final measurements; the DC resistance (DCR) value shall not exceed the maximum specification value at final measurements; no physical or mechani
10、cal damage shall be observed. 4.5 Testing in aqueous conditions 4.5.1 Load humidity test Inductors shall be tested in accordance with MIL-STD-202, Method 103, Test Condition C where applicable except: a) Inductors are to be electrically tested per section 4.3 b) preconditioning is required as specif
11、ied in Section 5 c) test temperature 85 3oC d) relative humidity shall be held at 85% e) power the units at 10% of their rated current continuously applied for 1000 hours f) measurements shall be taken at 0 h and 1000 h. g) the inductors shall be allowed to stabilize at room temperature for 24 hours
12、 before final measurements are taken h) the inductance value shall not change by more than (Refer to 4.2 Maximum Inductance Change Chart Table 2) from the initial value; the DCR value shall not exceed the maximum specification value at final measurements; no physical or mechanical damage shall be ob
13、served. 4.5.2 Moisture resistance Inductors shall be tested per MIL-STD-202 Method 106 except: a) Inductors are to be electrically tested per section 4.3 b) preconditioning is required as specified in Section 5 c) sequentially measure and record the initial inductance of each unit at: 25 2 C d) plac
14、e the units in a temperature/moisture chamber and subject them to 50 cycles per figure 1; readings must be taken at 0 cycles and 50 cycles e) at the conclusion of the last cycle, remove the units from the chamber. Stabilize at (25 2) C for a minimum of 4 hours to a maximum of 24 hours and sequential
15、ly remeasure the inductance; calculate and EIA-945 Page 6 Surface mount inductor qualification specification record the L change in % from the initial inductance value for each unit; the DCR value shall not exceed the maximum specification value at final measurement. LIMIT- the change in inductance
16、from initial to the end of the test shall not exceed the maximum % L specified, nor shall there be any evidence of mechanical abnormalities. EIA-945 Surface mount inductor qualification specification Page 7 EIA-945 Page 8 Surface mount inductor qualification specification 4.6 Thermal shock Inductors
17、 shall be tested either per MIL-STD-202, Method 107, where applicable except: a) Inductors are to be electrically tested per section 4.3 b) preconditioning is required as specified in Section 5; c) air-to-air Subject units to 500 cycles in the following sequence. Measurements shall be made at 0 cycl
18、es and 500 cycles. Step TemperatureC Time min 1. Start -40 2 2. Hold -40 2 30 5 3. Transfer 0.5 max. 4. Hold +105 2 30 5 5. Transfer 0.5 max. Or d) liquid-to-liquid; Subject units to 200 cycles in the following sequence. Measurements shall be made at 0 cycles and 200 cycles. Step TemperatureC Time 1
19、. Start -40 2 2. Hold -40 2 5 min (Min.) 3. Transfer 10 s 4. Hold +105 2 5 min (Min.) 5. Transfer 10 s d) the inductors shall be allowed to stabilize at room temperature for 24 hours before measurements are taken; at the intermediate and post readouts the inductance value shall not change by more th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECAEIA9452002SURFACEMOUNTINDUCTORQUALIFICATIONSPECIFICATION 表面 电感 合格 规范 PDF

链接地址:http://www.mydoc123.com/p-704498.html