ECA EIA-364-66A-2000 TP-66A EMI Shielding Effectiveness Test Procedure for Electrical Connectors《TP-66A 电连接器的EMI屏蔽效果试验规程》.pdf
《ECA EIA-364-66A-2000 TP-66A EMI Shielding Effectiveness Test Procedure for Electrical Connectors《TP-66A 电连接器的EMI屏蔽效果试验规程》.pdf》由会员分享,可在线阅读,更多相关《ECA EIA-364-66A-2000 TP-66A EMI Shielding Effectiveness Test Procedure for Electrical Connectors《TP-66A 电连接器的EMI屏蔽效果试验规程》.pdf(40页珍藏版)》请在麦多课文档分享上搜索。
1、 EIA STANDARD TP-66A EMI Shielding Effectiveness Test Procedure for Electrical Connectors EIA-364-66A (Revision of EIA 364-66) May 2000 EIA-364-66A ANSI/EIA-364-66A-2000(R2013) Approved: May 5, 2000 Reaffirmed: January 28, 2013 NOTICE EIA Engineering Standards and Publications are designed to serve
2、the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standar
3、ds and Publications shall not in any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than ECIA members, wh
4、ether the standard is to be used either domestically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, ECIA does not assume any liability to any patent owner, nor does it assume any ob
5、ligation whatever to parties adopting the Standard or Publication. This EIA Standard is considered to have International Standardization implication, but the International Electrotechnical Commission activity has not progressed to the point where a valid comparison between the EIA Standard and the I
6、EC document can be made. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of r
7、egulatory limitations before its use. Created under Standards Proposal No. 4730 and reaffirmed under Project No. 5253.01 under the cognizance of the CE-2.0 Committee on EIA National Connector and Socket Standards). Published by: Electronic Components Industry Association 2013 Engineering Department
8、2214 Rock Hill Road, Suite 170 Herndon, VA 20170 PLEASE! DONT VIOLATE THE LAW! This document is copyrighted by the ECIA and may not be reproduced without permission. Organizations may obtain permission to reproduce a limited number of copies through entering into a license agreement. For information
9、, contact: IHS 15 Inverness Way East Englewood, CO 80112-5704 or call USA and Canada (1-877-413-5184), International (303-397-7956) i CONTENTS Clause Page 1 Introduction . 1 1.1 Scope . 1 1.2 Object 1 1.2.1 General 1 1.2.2 Mode-stirred test chamber 1 1.2.3 Measurement of connector Shielding Effectiv
10、eness (SE) 2 1.2.4 Methods of measurements 3 2 Test resources . 4 2.1 Equipment . 4 2.1.1 Test chamber . 4 2.1.2 Input power monitoring 5 2.1.3 VSWR of components and cables . 5 2.1.4 Alternative test equipment configuration . 6 3 Test specimen 8 3.1 Description 8 3.2 Preparation 8 3.2.1 Impedance m
11、atch requirements 8 3.2.2 VSWR measurements . 10 3.2.3 Test specimen installation . 10 4 Test procedure . 10 4.1 Test frequencies 10 4.2 Measurement of power from reference antenna and CUT 11 ii Clause Page 4.3 Discrete tuning, test frequencies of 1 GHz to 2 GHz . 11 4.4 Acquiring test data 12 4.5 C
12、alculation of shielding effectiveness 13 5 Details to be specified . 14 6 Test documentation . 14 Table E.1 Circular connector center conductor diameter E-2 E.2 Rectangular connectors nominal dimensions for strip center conductor E-3 Figures 1 Mode-stirred shielding effectiveness system 4 2 Alternat
13、e test equipment configuration . 7 3 preparation and installation of test/specimen/conduit assembly 9 B.1 Mode-tuner construction . B-3 B.2 Details of collet for mounting tuner shaft to drive motor through wall of test chamber B-3 E.1 Cross sectional view of rectangular test specimen with flat-strip
14、 center conductor E-3 E.2 Rectangular connector/tapered adapter/conduit assembly E-4 Annex A Mode-stirred test chamber and antennas (informative) A-1 B Mode-tuner (informative) . B-1 C Test equipment and ancillary components (informative) . C-1 D Mismatch error corrections (informative) . D-1 E Test
15、 specimen and impedance matching (informative) E-1 F Test system dynamic range (informative) . F-1 G References (informative) G-1 EIA-364-66A Page 1 TEST PROCEDURE No. 66A EMI SHIELDING EFFECTIVENESS TEST PROCEDURE FOR ELECTRICAL CONNECTORS (From EIA Standards Proposal No. 4730, formulated under the
16、 cognizance EIA CE-2.0 Committee on National Connector Standards, and previously published in EIA-364-66.) 1 Introduction 1.1 Scope This standard establishes test methods for the measurement of the EMI shielding effectiveness of electrical connectors over the frequency range of 1.0 GHz to 10.0 GHz u
17、sing the mode-stirred technique. The procedure applies to both circular and rectangular connectors. 1.2 Object 1.2.1 General 1.2.1.1 The mode-stirred method for the measurement of connector shielding effectiveness consists of exposing the Connector Under Test (CUT) and a reference antenna to an elec
18、tromagnetic field and comparing the ratio of the signal levels induced into each unit. 1.2.1.2 The electromagnetic field within the mode-stirred test chamber is continuously perturbed by the operation of a rotating reflective element called a mode-stirrer (or tuner). 1.2.1.3 With the proper size tes
19、t chamber and appropriate antennas, the mode-stirred technique can be used over the frequency range of 200 MHz to 40 GHz. 1.2.2 Mode-stirred test chamber 1.2.2.1 The mode-stirred chamber is a large cavity (in terms of a wavelength) with a high quality factor (Q) whose boundary conditions are continu
20、ously perturbed by a rotating reflective surface (tuner or mode-stirrer) mounted within the chamber. Electromagnetic power is established inside the chamber by means of an input or transmitting antenna; see figure 1. EIA-364-66A Page 2 1.2.2.2 The time-averaged electromagnetic fields within the cham
21、ber are approximately equal in amplitude spatially, and are formed by uniformly distributed plane waves. The field distribution at each point in the chamber is then a composite of randomly polarized plane waves; therefore, the average response for the effective aperture of a receiving antenna (or th
22、e connector under test) placed inside the chamber approaches a value equivalent to a gain of unity. 1), 2)1.2.3 Measurement of connector Shielding Effectiveness (SE) 1.2.3.1 The measurement of SE is based on the comparison of the rf power induced into the CUT on the rf power induced into a reference
23、 antenna; see figure 1. The shielding effectiveness of the CUT (expressed in dB) is then defined as: cutrefPPlog 10 SE (dB) where: Pcut = Power coupled to the connector under test Pref = Power coupled to the reference antenna 1.2.3.2 Both the value of Pcut and Pref are determined statistically as a
24、function of tuner position and are determined for the same net input power applied to the chamber. 1.2.3.3 The leakage to be measured is principally that which enters the connector shells under test at the main point of interface. Leakage at the accessory joints is to be prevented by appropriate fix
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECAEIA36466A2000TP66AEMISHIELDINGEFFECTIVENESSTESTPROCEDUREFORELECTRICALCONNECTORSTP66A 连接器 EMI 屏蔽 效果

链接地址:http://www.mydoc123.com/p-704300.html