ECA EIA-364-20E-2015 TP-20E Withstanding Voltage Test Procedure for Electrical Connectors Sockets and Coaxial Contacts (2).pdf
《ECA EIA-364-20E-2015 TP-20E Withstanding Voltage Test Procedure for Electrical Connectors Sockets and Coaxial Contacts (2).pdf》由会员分享,可在线阅读,更多相关《ECA EIA-364-20E-2015 TP-20E Withstanding Voltage Test Procedure for Electrical Connectors Sockets and Coaxial Contacts (2).pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、 EIA STANDARD TP-20E Withstanding Voltage Test Procedure for Electrical Connectors, Sockets and Coaxial Contacts EIA-364-20E (Revision of EIA-364-20D) February 2015 Electronic Components Industry Association ANSI/EIA-364-20E-2015 Approved: February 11, 2015 EIA-364-20E NOTICE EIA Engineering Standar
2、ds and Publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his
3、particular need. Existence of such Standards and Publications shall not in any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntar
4、y use by those other than ECIA members, whether the standard is to be used either domestically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, ECIA does not assume any liability to a
5、ny patent owner, nor does it assume any obligation whatever to parties adopting the Standard or Publication. This standard is based upon the major technical content of International Electrotechnical Commission standard 60512-4-1, voltage proof, 2003-05. It conforms in all essential respects this IEC
6、 standard. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of regulatory limi
7、tations before its use. (From Standards Proposal No. 5322, formulated under the cognizance of the CE-2.0 Committee on EIA National Connector and Sockets Standards.) Published by Electronic Components Industry Association 2015 EIA Standards see 2.1.5. EIA-364-20E Page 5 4.6.1 Number of contacts (Only
8、 applicable to methods A, B and C) Unless otherwise specified in the referencing document, a minimum of five measurements (5 adjacent contacts and/or 5 contacts-to-shell and/or 5 contacts-to-base plate) or 10% of the total number of contacts (whichever is greater) shall be made for each case, per te
9、st specimen. 5 Details to be specified The following details shall be specified in the referencing document: 5.1 Special high voltage source, if applicable; see 2.1.1 5.2 Minimum kilovolt ampere rating, if applicable; see 2.1.1 5.3 Current surge limits, and limiting device, if applicable; see 2.1.1
10、5.4 Voltmeter accuracy, if other than at least 5 %; see 2.1.2 5.5 Leakage current if other than specified in 2.1.5 5.6 Define test specimen (mated or unmated); see 3.1 5.7 Special preparations or conditions, if required; see 3.2 5.8 Method of connection of test voltage to specimen, if significant; s
11、ee 3.2 5.9 Points of application of test voltage; see 4.1 5.10 Barometric pressure; see 4.2 5.10.1 Dielectric withstanding voltage requirements at sea level; see 4.2 5.10.2 Dielectric withstanding voltage requirements at reduced pressure, if applicable; see 4.2 5.10.3 Test during and after subjectio
12、n to reduced pressure; see 4.2.1 5.10.4 Method of mounting in test chamber; see 4.2.1 5.11 Magnitude of test voltage; see 4.3 5.12 Nature of potential (ac or dc); see 4.3 EIA-364-20E Page 6 5.13 Test voltage and duration for implant quality conformance testing; see 4.5 5.14 Duration of application o
13、f test voltage for qualification testing if other than 60 seconds; see 4.5 5.15 Examination and measurement of specimen, detail requirements (if required) ; see 4.6 5.16 Number of specimens to be tested. 6 Test documentation Documentation shall contain the details specified in clause 5, with any exc
14、eptions, and the following: 6.1 Title of test 6.2 Specimen description include fixturing 6.3 Test equipment used, and date of last and next calibration 6.4 Test procedure 6.5 Values and observations 6.6 Name of operator and start/finish date(s) of test EIA-364-20E Page A-1 Annex A A Normative A.1 Th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECAEIA36420E2015TP20EWITHSTANDINGVOLTAGETESTPROCEDUREFORELECTRICALCONNECTORSSOCKETSANDCOAXIALCONTACTS2PDF

链接地址:http://www.mydoc123.com/p-704236.html