ECA EIA-364-14B-1999 TP-14B Ozone Exposure Test Procedure for Electrical Connectors.pdf
《ECA EIA-364-14B-1999 TP-14B Ozone Exposure Test Procedure for Electrical Connectors.pdf》由会员分享,可在线阅读,更多相关《ECA EIA-364-14B-1999 TP-14B Ozone Exposure Test Procedure for Electrical Connectors.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、 EIA STANDARD TP-14B Ozone Exposure Test Procedure For Electrical Connectors EIA-364-14B (Revision of EIA-364-14A) April 1999 ELECTRONIC COMPONENTS, ASSEMBLIES & MATERIALS ASSOCIATION THE ELECTRONIC COMPONENTS SECTOR OF THE ELECTRONIC INDUSTRIES ALLIANCE ANSI/EIA-364-14B-1999 (R2012)Approved: April
2、7, 1999Reaffirmed:April 16, 2012 EIA-364-14BNOTICEEIA Engineering Standards and Publications are designed to serve the public interest througheliminating misunderstandings between manufacturers and purchasers, facilitatinginterchangeability and improvement of products, and assisting the purchaser in
3、 selecting andobtaining with minimum delay the proper product for his particular need. Existence of suchStandards and Publications shall not in any respect preclude any member or nonmember of EIAfrom manufacturing or selling products not conforming to such Standards and Publications, norshall the ex
4、istence of such Standards and Publications preclude their voluntary use by those otherthan EIA members, whether the standard is to be used either domestically or internationally.Standards and Publications are adopted by EIA in accordance with the American NationalStandards Institute (ANSI) patent po
5、licy. By such action, EIA does not assume any liability toany patent owner, nor does it assume any obligation whatever to parties adopting the Standard orPublication.This EIA Standard is considered to have International Standardization implication, but theInternational Electrotechnical Commission ac
6、tivity has not progressed to the point where a validcomparison between the EIA Standard and the IEC document can be made.This Standard does not purport to address all safety problems associated with its use or allapplicable regulatory requirements. It is the responsibility of the user of this Standa
7、rd to establishappropriate safety and health practices and to determine the applicability of regulatory limitationsbefore its use.(From Standards Proposal No. 4305, formulated under the cognizance of the CE-2.0 NationalConnector Standards Committee. Reaffirmation Project 5226.03)Published byELECTRON
8、IC INDUSTRIES ALLIANCE 1999Engineering Department2500 Wilson BoulevardArlington, VA 22201PRICE: Please refer to the currentCatalog of EIA Standards and Engineering Publicationsor call IHS, USA and Canada (1-800-854-7179)International (303-397-7956)All rights reservedPrinted in U.S.A.PLEASE!DON”T VIO
9、LATETHELAW!This document is copyrighted by the EIA and may not be reproduced withoutpermission.Organizations may obtain permission to reproduce a limited number of copiesthrough entering into a license agreement. For information, contact:IHS15 Inverness Way EastEnglewood, CO 80112-5704 or callU.S.A.
10、 and Canada 1-800-854-7179, International (303) 397-7956iCONTENTSClause Page1 Introduction 11.1 Scope . 12 Test resources 12.1 Equipment 12.1.1 Test chamber 12.1.2 Ozone generator . 22.1.3 Ozone measuring device . 23 Test specimen . 33.1 Description . 33.2 Preparation . 34 Test procedure 34.1 Condit
11、ions 34.2 Failures . 35 Details to be specified . 46 Test documentation 4ii(This page left blank)EIA-364-14BPage 1TEST PROCEDURE No. 14BOZONE EXPOSURE TEST PROCEDUREFORELECTRICAL CONNECTORS(From EIA Standards Proposal No. 4305, formulated under the cognizance EIA CE-2.0Committee on National Connecto
12、r Standards, and previously published in EIA-RS-364-14A.)1 Introduction1.1 ScopeThis standard establishes a test method to assess the ability of connectors to withstand the effectsof controlled amounts of ozone and still maintain effective environmental protection.CAUTION Since ozone is a toxic gas,
13、 care shall be exercised when using it to performthe testing called out herein.2 Test resources2.1 EquipmentThe test equipment shall be as follows and in accordance with ASTM-D-1149-64.2.1.1 Test chamberThe ozone test chamber shall conform to the following requirements:2.1.1.1 The test chamber shall
14、 be constructed of a material with minimal reaction to ozone.2.1.1.2 The minimum chamber volume shall be 0.14 cubic meter (5 cubic feet).A means for generating and controlling an air-ozone stream shall be provided. The generatingsource shall be located outside the chamber. The air can be drawn eithe
15、r directly from thelaboratory or from a compressed air supply. In either case, adequate filtration of foreign matterfrom the stream shall be provided. If the ozone generating source is a silent arc discharge, the airsupplied to the ozone generator shall be pre-dried to -51 C (-60 F) dew point or low
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECAEIA36414B1999TP14BOZONEEXPOSURETESTPROCEDUREFORELECTRICALCONNECTORSPDF

链接地址:http://www.mydoc123.com/p-704228.html