《ECA EIA-364-111A-2015 TP-111A Determining the Total Ionic Contamination Test Procedure for Electrical Connectors Socket Assemblies or Components (2).pdf》由会员分享,可在线阅读,更多相关《ECA EIA-364-111A-2015 TP-111A Determining the Total Ionic Contamination Test Procedure for Electrical Connectors Socket Assemblies or Components (2).pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、 EIA STANDARD TP-111A Determining the Total Ionic Contamination Test Procedure for Electrical Connectors, Socket Assemblies, or Components EIA-364-111A (Revision of EIA-364-111) September 2015 Electronic Components Industry Association EIA-364-111A ANSI/EIA-364-111A-2015 Approved: September 3, 2015
2、NOTICE EIA Engineering Standards and Publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum del
3、ay the proper product for his particular need. Existence of such Standards and Publications shall not in any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Public
4、ations preclude their voluntary use by those other than ECIA members, whether the standard is to be used either domestically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, ECIA does
5、 not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the Standard or Publication. This EIA Standard is considered to have International Standardization implications, but the International Electrotechnical Commission activity has not progressed
6、 to the point where a valid comparison between the EIA Standard and the IEC document can be made. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish approp
7、riate safety and health practices and to determine the applicability of regulatory limitations before its use. (From Standards Proposal No. 5347.05 formulated under the cognizance of the CE-2.0 Committee on EIA National Connector and Sockets Standards.) Published by Electronic Components Industry As
8、sociation 2015 EIA Standards & Technology Department 2214 Rock Hill Road, Suite 265 Herndon, VA 20170 PLEASE ! DONT VIOLATE THE LAW! This document is copyrighted by the ECIA and may not be reproduced without permission. Organizations may obtain permission to reproduce a limited number of copies thro
9、ugh entering into a license agreement. For information, contact: IHS 15 Inverness Way East Englewood, CO 80112-5704 or call USA and Canada (1-877-413-5186), International (303-397-7956) i CONTENTS Clause Page 1 Introduction . 1 1.1 Scope . 1 1.1.1 Method A, Ionography 1 1.1.2 Method B, Ion chromatog
10、raphy 1 1.2 Object 1 1.3 Definitions . 1 2 Test resources 2 2.1 Equipment . 2 2.1.1 Method A, Ionography 2 2.1.2 Method B, Ion chromatography 3 2.2 Material . 3 2.2.1 Method A, Ionography 3 2.2.2 Method B, Ion chromatography 3 3 Test specimen 4 3.1 Description 4 3.2 Preparation 4 4. Test procedure .
11、 4 4.1 Method A, Ionography 4 4.2 Method B, Ion chromatography 6 5 Details to be specified . 9 6 Test documentation . 9 Table 1 Common ions of interest . 8 ii (This page left blank) EIA-364-111A Page 1 TEST PROCEDURE No. 111A DETERMINING IONIC CONTAMINATION TEST PROCEDURE FOR ELECTRICAL CONNECTORS,
12、SOCKET ASSEMBLIES, OR COMPONENTS (From EIA Standards Proposal No. 5347.05, formulated under the cognizance EIA CE-2.0 Committee on National Connector and Socket Standards, and previously published in EIA-364-111.) 1 Introduction 1.1 Scope This standard establishes 2 methods for determining the total
13、 amount of extractable ionic contamination on the surface of an electrical connector or socket assembly or component. 1.1.1 Method A, Ionography A test method for quantifying the extractable ionic contamination on the surface of an electrical connector or socket assembly or component using an ionogr
14、aph contamination measurement system as determined in sodium chloride (NaCl) equivalents. 1.1.2 Method B, Ion chromatography A test method for quantifying and identifying the extractable ionic species on the surface of an electrical connector or socket assembly or component using an ion chromatograp
15、h system. Ion chromatography results are reported in parts per million of ionic species. 1.2 Object The object of this test procedure is to determine the amount of ionic contamination that may be present on the surface of a connector or socket assembly or component (either plastic or metallic). The
16、source of the contamination may be in the materials of construction or in residues from manufacturing processes. If excessive, the reliability of electronic equipment utilizing the connector or socket assembly or component may be compromised. 1.3 Definitions 1.3.1 Total ionic contamination Soluble i
17、onic species such as inorganic salts or weak organic acids EIA-364-111A Page 2 1.3.2 Connector or socket assembly Functional part consisting of conjoined components. 1.3.3 Connector or socket component Individual piece of an assembly such as a housing, a contact, a shield, a guide pin, a retention d
18、evice, or other miscellaneous hardware. 1.3.4 Baseline Line where the test starts 1.3.5 NaCl equivalents Units of concentration of a species reported based on the equivalent weight of NaCl 1.3.6 Eluent The solvent used to carry the extracted ions through the ion exchange chromatograph 1.3.7 Diluent
19、Solvent used for dilutions 1.3.8 Column Analytical exchanger used in ion chromatography to separate ionic species 2 Test resources 2.1 Equipment The following equipment is required: 2.1.1 Method A, Ionography 2.1.1.1 Ionograph contamination measurement system with a temperature compensated conductiv
20、ity sensor capable of measuring 0.2 g/ml of NaCl 2.1.1.2 Analytical balance (with a resolution of 0.5 milligrams) 2.1.1.3 Miscellaneous glass or plastic ware EIA-364-111A Page 3 2.1.1.4 Clean gloves or forceps 2.1.1.5 Hydrometer suitable of measuring a specific gravity of 0.855 0.0005 2.1.1.6 Microp
21、ipettes or Class A pipettes, capable of measuring 1 milliliter and 5 milliliters 2.1.1.7 Class A one-liter volumetric flasks 2.1.2 Method B, Ion chromatography A person with experience in ion chromatography should perform this procedure. 2.1.2.1 Ion chromatograph (IC) 2.1.2.2 Analytical columns (cap
22、able of resolving ions of interest) 2.1.2.3 Analytical balance (capable of milligram measurement) 2.1.2.4 Miscellaneous clean glass or plastic ware 2.1.2.5 Clean gloves or forceps 2.1.2.6 Unused, sealable, plastic bags capable of temperatures of 80 C 5 C 2.1.2.7 Water bath (capable of maintaining a
23、constant temperature of 80 C 5 C) 2.2 Material 2.2.1 Method A, Ionography 2.2.1.1 Isopropanol, reagent grade (IPA) 2.2.1.2 Deionized water (DI water) 2.2.1.3 Sodium chloride (NaCl), reagent grade, 750 micrograms per liter (ppm) recommended 2.2.2 Method B, Ion chromatography 2.2.2.1 Aqueous buffer so
24、lutions recommended for each column used for ionic separation 2.2.2.2 Certified standards for ions to be tested 2.2.2.3 Isopropanol, reagent grade (IPA) 2.2.2.4 Deionized water (DI water) EIA-364-111A Page 4 3 Test specimen 3.1 Description Connector or socket assembly or component 3.2 Preparation CA
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECAEIA364111A2015TP111ADETERMININGTHETOTALIONICCONTAMINATIONTESTPROCEDUREFORELECTRICALCONNECTORSSOCKETASSEMBLIESORCOMPONENTS2PDF

链接地址:http://www.mydoc123.com/p-704213.html