ECA EIA-364-10G-2017 TP-10G Fluid Immersion Test Procedure for Electrical Connectors.pdf
《ECA EIA-364-10G-2017 TP-10G Fluid Immersion Test Procedure for Electrical Connectors.pdf》由会员分享,可在线阅读,更多相关《ECA EIA-364-10G-2017 TP-10G Fluid Immersion Test Procedure for Electrical Connectors.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、EIASTANDARD TP-10G Fluid Immersion Test Procedure for Electrical Connectors EIA-364-10G (Revision of EIA-364-10F) November 2017 Electronic Components Industry Association EIA-364-10GANSI/EIA-364-10G-2017 Approved: November 20, 2017NOTICEEIA Engineering Standards and Publications are designed to serv
2、e the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Stand
3、ards and Publications shall not in any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than ECIA members,
4、whether the standard is to be used either domestically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, ECIA does not assume any liability to any patent owner, nor does it assume any
5、obligation whatever to parties adopting the Standard or Publication. This EIA Standard is considered to have International Standardization implication, but the International Electrotechnical Commission activity has not progressed to the point where a valid comparison between the EIA Standard and the
6、 IEC document can be made. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of
7、 regulatory limitations before its use. (From Standards Proposal No. 5388, formulated under the cognizance of the CE-2.0 Committee on EIA National Connector and Sockets Standards.) Published by Electronic Components Industry Association 2017 EIA Standards see EIA-364-13. EIA-364-10G Page 3 4.2 Prehe
8、at each test fluid until it has stabilized at the temperature specified; see table 1 or the referencing document. 4.3 The test cycle shall be as specified for each test fluid; see table 1 or the referencing document. 4.4 Transition time between steady state conditions shall be two minutes maximum an
9、d steady state conditions shall be maintained at the specified time with a tolerance of plus one minute unless otherwise specified in the referencing document. 4.5 Fluid shall be drained from all recesses by gravity. 4.6 Connectors shall be placed in an air-circulating oven for the time specified in
10、 table 1. Repeat number of cycles specified. 4.7 Remove the specimens and allow them to stabilize at room temperature for a minimum of 1 hour. 4.8 The final torques or forces required to mate and unmate each connector or connector assembly shall be measured and recorded, if the referencing document
11、test schedule includes mating and unmating measurements after the immersion test; see EIA-364-13. 4.9 Connectors shall be visually examined with the unaided eye for evidence of degradation. Examples of visible degradation from this test may be: 4.9.1 Swelling, cracking or pitting of any resilient ma
12、terial. 4.9.2 Loss of seal or adhesive bonding between two bonded surfaces. 4.9.3 Discoloration of materials, finishes and marking, but this may not be considered detrimental. 5 Details to be specified The following details shall be specified in the referencing document: 5.1 Number of specimens test
13、ed for each fluid 5.2 Whether connector is immersed mated or unmated 5.3 Test condition (fluids to be used); see table 1 5.4 Other fluids, not listed in table 1, shall be specified along with their test conditions 5.4 Type of wire insulation if other than TFE 5.5 Test cycle duration and temperature
14、of fluid, if other than as specified in table 1 5.6 Torque or force measurements to mate and unmate, if applicable EIA-364-10G Page 4 6 Documentation Documentation shall contain the details specified in clause 5, with any exceptions, and the following: 6.1 Title of test 6.2 Specimen description and
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECAEIA36410G2017TP10GFLUIDIMMERSIONTESTPROCEDUREFORELECTRICALCONNECTORSPDF

链接地址:http://www.mydoc123.com/p-704212.html