1、A-A-54491 65 W 9999974 0062537 O W A-A-5449 1 30 Sepkemker 1991 COMMERCIAL ITEM DESCRIPTION CANNULA, TRACHEQTOMY, UNIVERSITY OF KANSAS DESIGN The eneral Services Administration has authorized the use Qf this Cqmmeriql Icem Pessrigtisp as a replacement for Vilitary Specifisatisn MIL-C-36672(1) which
2、is cancelled, This Commercial Item Pescriptia covers metal tracheotomy cannulae of the University 9f Kansas design for use in performing cricothyroiadomy, Salient characteristics: General. The tracheotamy Qbnnulae shall be of the University of Kansas design, used in performing cricothyreidotomy, Ali
3、 inner tubes and outer sleeves shall be interchangeable with each other within the given size. The tracheotomy cannulae shall be of the following sizes: Size I - Adult Size i1 - Pediatric. Material. b-fabricated fram-types 303 or 304, class 3 stainless steel in accordance with ASTM F899, As an alter
4、nate, inner tube and outer sleeve shall be fabricated from types 316, 317, class 3 stainless steel in accordance with ASTM F899. All compgnenes of the tracheotomy cannulae shall Hardness. The tracheotomy cannulae shall have a Rockwell 1IardneSs of B75 minimum when tested in accordance with ACTM E18
5、or E92 whichever is appliGakle. Conversion of hardness values shall be in accordance with ASTM Eb40. AMSC N/A DISTRIBUTION STATEMENT A. Approved for public release; distributha is unlimited. FSC 6515 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-,
6、A-A-54491 65 W 9999974 0062518 2 W 1 - A-A-5449 1 Style, desisn and dimensions. Each tracheotomy unit shall consist of two components. fits within an outer curved bivalve sleeve member. inner member shall be concentric and secured by either welding or silver-soldering to a metal plate at the proxima
7、l end designed to permit ease of insertion into and removable from the outer member. The outer bivalve member shall also be permanently secured by either welding or silver-soldering to a metal retaining plate at the proximal end. Distal end of inner cannula shall be open and smoothly finished. The c
8、urved cannula (part 1, inner tube shown on drawing) shall be interchangeable with outer sleeve (part 2, on drawing) with other tracheotomy units being of the same size. (See Note 1) Tracheotomy unit shall be in strict accordance with Defense Personnel Support Center (DPSC) Drawing No. 24120. Finish.
9、 All components shall be polished to a smooth bright finish. Definitions of acceptable surface characteristics shall be as described in ASTM F86. Passivation. construction shall be properly passivated after completion of all final finishing operations. Passivation shall be accomplished by the method
10、s described in ASTM F86 or equivalent. Tracheotomy units that are of silver-solder construction shall be passivated before they are silver- soldered. A curved cannula member which The Tracheotomy units that are of welded Resistance to corrosion. The tracheotomy units shall not show evidence of corro
11、sion when tested in accordance with ASTM F1089. As an alternate, the following saline test may be used: water and rinse in hot water followed by immersion in ethyl alcohol (95%) and then dry. Tracheotomy units shall be completely immersed into Normal Saline Solution (USP) and while immersed, placed
12、into an oven at a temperature of 37+ 1 degrees centigrade for a period of seven (7) days, removed from the oven and examined for corrosion while still immersed. Scrub the tracheotomy units with soap and warm Identification markins. The tracheotomy units shall be legibly marked with the contractors n
13、ame or registered trademark, and the word llstainlessll. Foreign manufactured tracheotomy units shall bear the name of the country of origin. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-54491 - 65 9999974 0062539 4 = A-A-54 4 9 1 Workmanshi
14、p. The tracheotomy units shall be free from defects which detract from their appearance or impair their serviceability. Unit. Each (EA). One cannula of the size specified, constitutes one unit. 9UALITY ASSURANCE PROVISIONS. Responsibilitv for inspection. Unless otherwise specified in the contract or
15、 purchase order, the contractor is responsible for the performance of all inspection requirements as specified herein. Except otherwise specified in the contract or purchase order, the contractor may use his own or any facilities suitable for the performance of the inspection requirements specified
16、herein, unless disapproved by the Government. The Government reserves the right to perform any of the inspections set forth in the specification where such inspections are deemed necessary to assure supplies and services conform to prescribed requirements. Records. Records of examinations and tests
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DODAA544911991CANNULATRACHEOTOMYUNIVERSITYOFKANSASDESIGN 堪萨斯州 大学 涉及 气管 切开 套管 PDF

链接地址:http://www.mydoc123.com/p-701749.html