1、A-A-53843 65 7777779 0032357 4 = 3 A-A-53 8 43 24 March 1989 COMMERCIAL ITEM DESCRIPTION TUBING ASSEMBLY, SURGICAL IRRIGATOR The General Services Administration has authorized the use of this Commercial Item Description. This Commercial Item Description covers a sterile, disposable tubing assembly s
2、uitable for concurrent pulsed irrigation and suction in both trauma and surgery. Salient characteristics: The surgical irrigator tubing assembly shall be specifically designed for concurrent pulsed irrigation and suction in both trauma and surgery. set and a large handpiece with.three lumens: an irr
3、igation lumen, a control lumen, and a suction lumen, The assembly shall consist of a tubing The irrigation lumen shall be fabricated of polyvinylchloride tubing having approximate dimensions of 13 feet long, with a 3/16 inch I.D. and a 5/16 inch O.D. The lumen shall be fitted with an unvented pierci
4、ng spike for use with collapsible irrigation bags or bottles with vented caps. The control lumen shall be fabricated of polyvinylchloride tubing having approximate dimensions of 13 feet long, with an 1/8 inch I.D. and a 1/4 inch O.D. The suction lumen shall be fabricated of polyvinylchloride tubing
5、having approximate dimensions of 13 feet long, with a 5/16 inch I.D. and a 7/16 inch O.D. The suction tubing shall withstand 27 inches of mercury vacuum. An easily operated fingertip control for both suction and irrigation shall be provided on the handpiece. shall save time and shall not compromise
6、technique. Irrigation on demand via a closed, sterile, fluid path shall be provided. The design All tubing shall be non-kinking and drapable. AMSC N/A FSC 6530 DISTRIBUTION STATEMENT A. Approved for public release: distribution is unlimited. - THIS DOCUMENT CONTAINS d PAGES. - Provided by IHSNot for
7、 ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-53843 b5 7777974 0032Lb0 O m e A-A-5 3 8 43 Each assembly shall be furnished with a .I set . of instructions for use . The assembly shall be packaged in a suitable peel-open container which shall maintain sterility unles
8、s the package is damaged or opened. The assembly shall coinply with FDA requirements for sterility. The peel-open container shall be free of oil, grease, dirt, or other contamination on the outside surface. Workmanship. The surgical irrigator tubing assembly shall be free from defects which detract
9、from its appearance or impair its serviceability. Unit. Package (PG). One package containing ten individually packaged sterile tubing assemblies, as specified, constitutes one unit. Quality Assurance Provisions. the contract or purchase order, the contractor is responsible for the performance of all
10、 inspection requirements as specified herein. purchase order, the contractor may use his own or any facilities suitable for the performance of the inspection requirements specified herein, unless disapproved by the Government. Government reserves the right to perform any of the inspections set forth
11、 in the specification where such inspections are deemed necessary to assure supplies and services conform to prescribed requirements. Records. Records of examinations and tests performed by or or the contractor shall be maintained by the contractor and made available to the Government upon the Gover
12、nments request, at any time, or from time to time, during the performance of the contract and for a period of three years after delivery of the supplies to which such records relate. Responsibility for inspection. Unless otherwise specified in Except as otherwise specified in the contract or The Ins
13、pection. Inspection, as used herein, is defined as both examination (such as visual or auditory investigation without the use of special laboratory appliances or procedures) and testing (determination by technical means of physical and chemical properties) of the item. 2 Provided by IHSNot for Resal
14、eNo reproduction or networking permitted without license from IHS-,-,-A-A-53 8 43 . Tests. Tests shall be Conducted to determine compliance with specification requirements: shall be used for the determination of two or more test characteristics, Where feasible, the same sample Samplinq for examinati
15、on. Sampling for examination shall be conducted in accordance with MIL-STD-105, with an AQL of 1.0 (percent defective) and an inspection level of II. product for examination purposes shall be one surgical irrigator tubing assembly as specified in this description. The unit of Defects . Assembly is n
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DODAA538431989TUBINGASSEMBLYSURGICALIRRIGATOR 外科 注射器 试管 组装 PDF

链接地址:http://www.mydoc123.com/p-701688.html