DLA SMD-5962-93192 REV G-2012 MICROCIRCUIT HYBRID LINEAR 12 VOLT DUAL CHANNEL DC-DC CONVERTER.pdf
《DLA SMD-5962-93192 REV G-2012 MICROCIRCUIT HYBRID LINEAR 12 VOLT DUAL CHANNEL DC-DC CONVERTER.pdf》由会员分享,可在线阅读,更多相关《DLA SMD-5962-93192 REV G-2012 MICROCIRCUIT HYBRID LINEAR 12 VOLT DUAL CHANNEL DC-DC CONVERTER.pdf(19页珍藏版)》请在麦多课文档分享上搜索。
1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Changes in accordance with NOR 5962-R251-94. 94-07-25 K. A. Cottongim B Add case outlines T, U, Y, and Z. 98-02-23 K. A. Cottongim C Update drawing boilerplate. 04-07-28 Raymond Monnin D Add device type 02, Add paragraph 1.5 and footnote 2/. Tabl
2、e I add footnote 1/. Table I add footnote 2/ for enhanced low dose rate effects. Add paragraph 3.2.3 for Radiation exposure circuit. Update paragraph 4.3.5 for Rad Hard devices. 07-04-03 Robert M. Heber E Add RHA levels P and L to device type 02 in paragraphs 1.3, 4.3.5 (table), table I, and SMD bul
3、letin. -gz 07-07-02 Robert M. Heber F Added footnote 1 to table II, under group C end-point electricals. Updated drawing paragraphs. -sld 09-09-08 Charles F. Saffle G Figure 1, Case outline X; Changed dimension from “E1“ to “E“ and the dimension from “E2“ to “E1“. Updated drawing paragraphs. -sld 12
4、-06-01 Charles F. Saffle REV SHEET REV G G G SHEET 15 16 17 REV STATUS REV G G G G G G G G G G G G G G OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 10 11 12 13 14 PMIC N/A PREPARED BY Steve L. Duncan DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 http:/www.landandmaritime.dla.mil/ STANDARD MICROCIRCUIT DRAWIN
5、G CHECKED BY Michael Jones THIS DRAWING IS AVAILABLE FOR USE BY ALL DEPARTMENTS APPROVED BY Kendall A. Cottongim MICROCIRCUIT, HYBRID, LINEAR, 12 VOLT, DUAL CHANNEL, DC-DC CONVERTER AND AGENCIES OF THE DEPARTMENT OF DEFENSE DRAWING APPROVAL DATE 94-05-26 AMSC N/A REVISION LEVEL G SIZE A CAGE CODE 67
6、268 5962-93192 SHEET 1 of 17 DSCC FORM 2233 APR 97 5962-E354-12 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-93192 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL G SHEET 2 DSCC FORM 2234 AP
7、R 97 1. SCOPE 1.1 Scope. This drawing documents five product assurance classes as defined in paragraph 1.2.3 and MIL-PRF-38534. A choice of case outlines and lead finishes which are available and are reflected in the Part or Identifying Number (PIN). When available, a choice of radiation hardness as
8、surance levels are reflected in the PIN. 1.2 PIN. The PIN shall be as shown in the following example: 5962 - 93192 01 H X A Federal RHA Device Device Case Lead stock class designator type class outline finish designator (see 1.2.1) (see 1.2.2) designator (see 1.2.4) (see 1.2.5) / (see 1.2.3) / Drawi
9、ng number 1.2.1 Radiation hardness assurance (RHA) designator. RHA marked devices shall meet the MIL-PRF-38534 specified RHA levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device. 1.2.2 Device type(s). The device type(s) identify the circuit function a
10、s follows: Device type Generic number Circuit function 01 MFL2812D DC-DC converter, 60 W, 12 V outputs 02 SMFL2812D DC-DC converter, 60 W, 12 V outputs 1.2.3 Device class designator. This device class designator shall be a single letter identifying the product assurance level. All levels are defined
11、 by the requirements of MIL-PRF-38534 and require QML Certification as well as qualification (Class H, K, and E) or QML Listing (Class G and D). The product assurance levels are as follows: Device class Device performance documentation K Highest reliability class available. This level is intended fo
12、r use in space applications. H Standard military quality class level. This level is intended for use in applications where non-space high reliability devices are required. G Reduced testing version of the standard military quality class. This level uses the Class H screening and In-Process Inspectio
13、ns with a possible limited temperature range, manufacturer specified incoming flow, and the manufacturer guarantees (but may not test) periodic and conformance inspections (Group A, B, C and D). E Designates devices which are based upon one of the other classes (K, H, or G) with exception(s) taken t
14、o the requirements of that class. These exception(s) must be specified in the device acquisition document; therefore the acquisition document should be reviewed to ensure that the exception(s) taken will not adversely affect system performance. D Manufacturer specified quality class. Quality level i
15、s defined by the manufacturers internal, QML certified flow. This product may have a limited temperature range. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-93192 DLA LAND AND MARITIME COLUMBUS, OHIO 43218
16、-3990 REVISION LEVEL G SHEET 3 DSCC FORM 2234 APR 97 1.2.4 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Terminals Package style T See figure 1 12 Tabbed flange mount, lead formed up U See figure 1 12 Flange mount, lead f
17、ormed down X See figure 1 12 Flange mount, short lead Y See figure 1 12 Tabbed flange mount, short lead Z See figure 1 12 Tabbed flange mount, lead formed down 1.2.5 Lead finish. The lead finish shall be as specified in MIL-PRF-38534. 1.3 Absolute maximum ratings. 1/ Input voltage range (VIN) 2/ -0.
18、5 V dc to +50 V dc Power dissipation (PD): Device types 01 and 02 (non-RHA) . 16 W Device type 02 (RHA levels P, L, and R) 18 W Lead soldering temperature (10 seconds) . +300 C Storage temperature range -65 C to +150 C 1.4 Recommended operating conditions. Input voltage range (VIN) +16 V dc to +40 V
19、 dc Output power . 60 W Case operating temperature range (TC) . -55 C to +125 C 1.5 Radiation features. Maximum total dose available (dose rate = 9 rad(Si)/s): Device type 02 (RHA levels P, L, and R) . 100 krad (Si) 3/ 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. T
20、he following specification, standards, and handbooks form a part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-38534 - Hybrid Microcircuits, Genera
21、l Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - Interface Standard for Electronic Component Case Outlines. 1/ Stresses above the absolute maximum ratings may cause permanent damage to the device. Extended operation at the maximum
22、levels may degrade performance and affect reliability. 2/ An under voltage lockout circuit shuts the unit off when the input voltage drops to approximately 12 V. Operation of the unit between 12 V and 16 V is non destructive. At reduced output power, regulation may be maintained, but performance is
23、not guaranteed. 3/ These parts may be dose rate sensitive in a space environment and may demonstrate enhanced low dose rate effects. Radiation end-point limits for the noted parameters are guaranteed only for the conditions as specified in MIL-STD-883, method 1019, condition C, tested at 9 rad(Si)/s
24、. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-93192 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL G SHEET 4 DSCC FORM 2234 APR 97 DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of St
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLASMD596293192REVG2012MICROCIRCUITHYBRIDLINEAR12VOLTDUALCHANNELDCDCCONVERTERPDF

链接地址:http://www.mydoc123.com/p-700366.html