DLA SMD-5962-93162 REV G-2012 MICROCIRCUIT HYBRID LINEAR 12 VOLT SINGLE CHANNEL DC-DC CONVERTER.pdf
《DLA SMD-5962-93162 REV G-2012 MICROCIRCUIT HYBRID LINEAR 12 VOLT SINGLE CHANNEL DC-DC CONVERTER.pdf》由会员分享,可在线阅读,更多相关《DLA SMD-5962-93162 REV G-2012 MICROCIRCUIT HYBRID LINEAR 12 VOLT SINGLE CHANNEL DC-DC CONVERTER.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Changes in accordance with NOR 5962-R249-94. 94-07-25 K. A. Cottongim B Changes in accordance with NOR 5962-R219-96. 96-09-12 K. A. Cottongim C Add case outlines T, U, Y, and Z. 98-02-23 K. A. Cottongim D Update drawing boilerplate. 04-07-28 Raym
2、ond Monnin E Add device type 02. For paragraph 1.3 Input voltage range, update footnote 2/ to add “regulation may be maintained”. Table I; delete test for “Short circuit current” Isc. Add RHA requirements for device type 02. gc 06-04-05 Raymond Monnin F Add paragraph 1.5 and note 3. Table I, add not
3、e for enhanced low dose rate effects. Paragraph 4.3.5.a, correct paragraph to add component tested dose rate. -sld 07-01-04 Raj Pithadia G Table II, added note to Group C end-point test parameters. Figure 1, Case outline X; Changed dimension from “E1“ to “E“ and the dimension from “E2“ to “E1“. Upda
4、ted drawing paragraphs. -sld 12-06-01 Charles F. Saffle REV SHEET REV G G SHEET 15 16 REV STATUS REV G G G G G G G G G G G G G G OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 10 11 12 13 14 PMIC N/A PREPARED BY Steve L. Duncan DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 http:/www.landandmaritime.dla.mil/ ST
5、ANDARD MICROCIRCUIT DRAWING CHECKED BY Michael Jones THIS DRAWING IS AVAILABLE FOR USE BY ALL DEPARTMENTS APPROVED BY Kendall A. Cottongim MICROCIRCUIT, HYBRID, LINEAR, 12 VOLT, SINGLE CHANNEL, DC-DC CONVERTER AND AGENCIES OF THE DEPARTMENT OF DEFENSE DRAWING APPROVAL DATE 94-05-24 AMSC N/A REVISION
6、 LEVEL G SIZE A CAGE CODE 67268 5962-93162 SHEET 1 OF 16 DSCC FORM 2233 APR 97 5962-E352-12 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-93162 DLA LAND AND MARITME COLUMBUS, OHIO 43218-3990 REVISION LEVEL
7、G SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope. This drawing documents five product assurance classes as defined in paragraph 1.2.3 and MIL-PRF-38534. A choice of case outlines and lead finishes which are available and are reflected in the Part or Identifying Number (PIN). When available, a choi
8、ce of radiation hardness assurance levels are reflected in the PIN. 1.2 PIN. The PIN shall be as shown in the following example: 5962 - 93162 01 H X A Federal RHA Device Device Case Lead stock class designator type class outline finish designator (see 1.2.1) (see 1.2.2) designator (see 1.2.4) (see 1
9、.2.5) / (see 1.2.3) / Drawing number 1.2.1 Radiation hardness assurance (RHA) designator. RHA marked devices shall meet the MIL-PRF-38534 specified RHA levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device. 1.2.2 Device type(s). The device type(s) iden
10、tify the circuit function as follows: Device type Generic number Circuit function 01 MFL2812S DC-DC converter, 60 W, +12 V output 02 SMFL2812S DC-DC converter, 60 W, +12 V output 1.2.3 Device class designator. This device class designator shall be a single letter identifying the product assurance le
11、vel. All levels are defined by the requirements of MIL-PRF-38534 and require QML Certification as well as qualification (Class H, K, and E) or QML Listing (Class G and D). The product assurance levels are as follows: Device class Device performance documentation K Highest reliability class available
12、. This level is intended for use in space applications. H Standard military quality class level. This level is intended for use in applications where non-space high reliability devices are required. G Reduced testing version of the standard military quality class. This level uses the Class H screeni
13、ng and In-Process Inspections with a possible limited temperature range, manufacturer specified incoming flow, and the manufacturer guarantees (but may not test) periodic and conformance inspections (Group A, B, C and D). E Designates devices which are based upon one of the other classes (K, H, or G
14、) with exception(s) taken to the requirements of that class. These exception(s) must be specified in the device acquisition document; therefore the acquisition document should be reviewed to ensure that the exception(s) taken will not adversely affect system performance. D Manufacturer specified qua
15、lity class. Quality level is defined by the manufacturers internal, QML certified flow. This product may have a limited temperature range. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-93162 DLA LAND AND MA
16、RITME COLUMBUS, OHIO 43218-3990 REVISION LEVEL G SHEET 3 DSCC FORM 2234 APR 97 1.2.4 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Terminals Package style T See figure 1 12 Tabbed flange mount, lead formed up U See figure
17、 1 12 Flange mount, lead formed down X See figure 1 12 Flange mount, short lead Y See figure 1 12 Tabbed flange mount, short lead Z See figure 1 12 Tabbed flange mount, lead formed down 1.2.5 Lead finish. The lead finish shall be as specified in MIL-PRF-38534. 1.3 Absolute maximum ratings. 1/ Input
18、voltage range (VIN) 2/ -0.5 V dc to +50 V dc Power dissipation (PD) . 16 W Lead soldering temperature (10 seconds) . +300 C Storage temperature range -65 C to +150 C 1.4 Recommended operating conditions. Input voltage range (VIN) +16 V dc to +40 V dc Output power . 60 W Case operating temperature ra
19、nge (TC) . -55 C to +125 C 1.5 Radiation features. Maximum total dose available (dose rate = 9 rad(Si)/s): Device type 02 (RHA level R) 100 krad (Si) 3/ 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part o
20、f this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-38534 - Hybrid Microcircuits, General Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 -
21、 Test Method Standard Microcircuits. MIL-STD-1835 - Interface Standard for Electronic Component Case Outlines. 1/ Stresses above the absolute maximum ratings may cause permanent damage to the device. Extended operation at the maximum levels may degrade performance and affect reliability. 2/ An under
22、voltage lockout circuit shuts the unit off when the input voltage drops to approximately 12 volts. Operation of the unit between 12 volts and 16 volts is nondestructive. At reduced output power, regulation may be maintained, but performance is not guaranteed. 3/ These parts may be dose rate sensitiv
23、e in a space enviroment and may demonstrate enhanced low dose rate effects. Radiation end-point limits for the the noted parameters are guaranteed only for the conditions as specified in MIL-STD-883, method 1019, condition C, tested at 9 rad(Si)/s. Provided by IHSNot for ResaleNo reproduction or net
24、working permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-93162 DLA LAND AND MARITME COLUMBUS, OHIO 43218-3990 REVISION LEVEL G SHEET 4 DSCC FORM 2234 APR 97 DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Standard
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLASMD596293162REVG2012MICROCIRCUITHYBRIDLINEAR12VOLTSINGLECHANNELDCDCCONVERTERPDF

链接地址:http://www.mydoc123.com/p-700344.html