1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Add case outline X. Remove figure 3, block diagram. 00-10-24 Raymond Monnin B Correct paragraphs 4.2.a.2. and 4.3.3.b.2. Figure 1, case outline Z, correct note 2. 06-11-01 Raymond Monnin C Table I: Change values in the conditions column for the f
2、ollowing tests; Line regulation, Load regulation, Input ripple current, Switching frequency, Sync frequency range, Output response to transient step line change, Recovery time transient step line changes, Turn on overshoot, and Turn on delay. Also, add the following to the end of footnote 3/ Table I
3、; “and at least 50 mA of the output power is taken from +/- auxiliary (+/-12 V or +/-15 V). -gc 06-11-01 Raymond Monnin D Table II, add note to Group C end-point test parameters. Paragraphs 4.2.a.2 and 4.3.3.b.2, reinstate original paragraphs. Update boilerplate paragraphs. -gz 11-11-17 Charles F. S
4、affle REV SHEET REV SHEET REV STATUS REV D D D D D D D D D D D D OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 10 11 12 PMIC N/A PREPARED BY Gary Zahn DLA LAND AND MARITIME STANDARD MICROCIRCUIT DRAWING CHECKED BY Michael C. Jones COLUMBUS, OHIO 43218-3990 http:/www.landandmaritime.dla.mil THIS DRAWING IS AVAIL
5、ABLE FOR USE BY ALL DEPARTMENTS APPROVED BY Kendall A. Cottongim MICROCIRCUIT, HYBRID, LINEAR, +5 AND 12 VOLT, TRIPLE CHANNEL, DC-DC CONVERTER AND AGENCIES OF THE DEPARTMENT OF DEFENSE DRAWING APPROVAL DATE 93-06-23 AMSC N/A REVISION LEVEL D SIZE A CAGE CODE 67268 5962-93158 SHEET 1 OF 12 DSCC FORM
6、2233 APR 97 5962-E077-12Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-93158 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope. This drawing do
7、cuments five product assurance classes as defined in paragraph 1.2.3 and MIL-PRF-38534. A choice of case outlines and lead finishes which are available and are reflected in the Part or Identifying Number (PIN). When available, a choice of radiation hardness assurance levels are reflected in the PIN.
8、 1.2 PIN. The PIN shall be as shown in the following example: 5962 - 93158 01 H X X Federal RHA Device Device Case Lead stock class designator type class outline finish designator (see 1.2.1) (see 1.2.2) designator (see 1.2.4) (see 1.2.5) / (see 1.2.3) / Drawing number 1.2.1 Radiation hardness assur
9、ance (RHA) designator. RHA marked devices shall meet the MIL-PRF-38534 specified RHA levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device. 1.2.2 Device type. The device type identify the circuit function as follows: Device type Generic number Circuit
10、function 01 ATR2812T/CH, ATR2812TF/CH DC-DC converter, 30 W, +5 V and 12 V triple output 1.2.3 Device class designator. This device class designator shall be a single letter identifying the product assurance level. All levels are defined by the requirements of MIL-PRF-38534 and require QML Certifica
11、tion as well as qualification (Class H, K, and E) or QML Listing (Class G and D). The product assurance levels are as follows: Device class Device performance documentation K Highest reliability class available. This level is intended for use in space applications. H Standard military quality class
12、level. This level is intended for use in applications where non-space high reliability devices are required. G Reduced testing version of the standard military quality class. This level uses the Class H screening and In-Process Inspections with a possible limited temperature range, manufacturer spec
13、ified incoming flow, and the manufacturer guarantees (but may not test) periodic and conformance inspections (Group A, B, C, and D). E Designates devices which are based upon one of the other classes (K, H, or G) with exception(s) taken to the requirements of that class. These exception(s) must be s
14、pecified in the device acquisition document; therefore the acquisition document should be reviewed to ensure that the exception(s) taken will not adversely affect system performance. D Manufacturer specified quality class. Quality level is defined by the manufacturers internal, QML certified flow. T
15、his product may have a limited temperature range. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-93158 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 3 DSCC FORM 2234 APR 97 1.2.4 Cas
16、e outlines. The case outlines are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Terminals Package style X See figure 1 10 Dual-in line Z See figure 1 10 Flange mount 1.2.5 Lead finish. The lead finish shall be as specified in MIL-PRF-38534. 1.3 Absolute maximum
17、ratings. 1/ Input voltage range -0.5 V dc to +50 V dc Power dissipation. 14 W Lead temperature (soldering, 10 seconds) +300C Storage temperature -65C to +150C 1.4 Recommended operating conditions. Input voltage range +16 V dc to +40 V dc Output currents: +5 V output 2/ 3/ +100 mA to +4000 mA +12 V o
18、utput 2/ 3/ 625 mA Output power 2/ 4/ . 30 W Case operating temperature range (TC) -55C to +125C 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part of this drawing to the extent specified herein. Unless ot
19、herwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-38534 - Hybrid Microcircuits, General Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - Inte
20、rface Standard for Electronic Component Case Outlines. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Standard Microcircuit Drawings. (Copies of these documents are available online at https:/assist.daps.dla.mil/quicksearch/ or from the Standard
21、ization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text of this drawing takes precedence. Nothing in this document, however, supersedes a
22、pplicable laws and regulations unless a specific exemption has been obtained. 1/ Stresses above the absolute maximum ratings may cause permanent damage to the device. Extended operation at the maximum levels may degrade performance and affect reliability. 2/ Although operation with no load is permis
23、sible, light loading on the main (+5 volt) output may cause the output voltage of the auxiliary outputs (12 volt) to drop out of regulation. It is therefore recommended that at least 100 mA or 20 percent of the total output power, whichever is greater, be taken from the main (+5 volt) output. 3/ Tot
24、al combined output power not to exceed 30 watts. 4/ Derate output power linearly above case temperature +125C to 0 at +135C. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-93158 DLA LAND AND MARITIME COLUMBU
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLASMD596293158REVD2011MICROCIRCUITHYBRIDLINEAR5ANDPLUSMINUS12VOLTTRIPLECHANNELDCDCCONVERTERPDF

链接地址:http://www.mydoc123.com/p-700341.html