DLA SMD-5962-91664 REV F-2009 MICROCIRCUIT HYBRID LINEAR 12-VOLT SINGLE CHANNEL DC-DC CONVERTER.pdf
《DLA SMD-5962-91664 REV F-2009 MICROCIRCUIT HYBRID LINEAR 12-VOLT SINGLE CHANNEL DC-DC CONVERTER.pdf》由会员分享,可在线阅读,更多相关《DLA SMD-5962-91664 REV F-2009 MICROCIRCUIT HYBRID LINEAR 12-VOLT SINGLE CHANNEL DC-DC CONVERTER.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Changes in accordance with NOR 5962-R158-93. 93-05-11 K. A. Cottongim B Added case outline Z. Redrew entire document. 95-06-15 K. A. Cottongim C Add device type 02, Radiation Hardness Assurance (RHA) requirements and class K devices. Correct para
2、graphs 4.2.a.2 and 4.3.3.b.2 from TCto TA. Table I, change VINconditions from “16 , 28, and 40 V dc“ to “16 V dc to 40 V dc“. Figure 1, case outline X, change dimensions D maximum from 1.455“ to 1.460“ and E maximum from 1.125“ to 1.130“. Update entire document. 04-08-31 Raymond Monnin D Add paragra
3、ph 1.5 and note 2. Table I, added note for enhanced low dose rate effects. Paragraph 4.3.5.a, correct paragraph to add component tested dose rate. Table I; change the maximum limit for the input current test (IIN) device type 02 from 50 mA to 55 mA. -sld 06-12-27 Raymond Monnin E Update Table I to i
4、nclude RHA level “P“. Update table in paragraph 4.3.5 to include RHA level “P “. Update bulletin page to include RHA level “P“ part numbers. gc 07-05-31 Robert M. Heber F Added footnote 1 to table II, under group C end-point electricals. Updated drawing paragraphs. -sld 09-08-03 Charles F. Saffle RE
5、V SHEET REV SHEET REV STATUS REV F F F F F F F F F F F F F OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 10 11 12 13 PMIC N/A PREPARED BY Steve L. Duncan DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 http:/www.dscc.dla.mil STANDARD MICROCIRCUIT DRAWING CHECKED BY Michael Jones THIS DRAWING IS AVAILAB
6、LE FOR USE BY ALL DEPARTMENTS APPROVED BY Alan Barone MICROCIRCUIT, HYBRID, LINEAR, 12-VOLT, SINGLE CHANNEL, DC-DC CONVERTER AND AGENCIES OF THE DEPARTMENT OF DEFENSE DRAWING APPROVAL DATE 92-08-18 AMSC N/A REVISION LEVEL F SIZE A CAGE CODE 67268 5962-91664 SHEET 1 OF 13 DSCC FORM 2233 APR 97 5962-E
7、402-09Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-91664 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL F SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope. This drawing documents f
8、ive product assurance classes as defined in paragraph 1.2.3 and MIL-PRF-38534. A choice of case outlines and lead finishes which are available and are reflected in the Part or Identifying Number (PIN). When available, a choice of radiation hardness assurance levels are reflected in the PIN. 1.2 PIN.
9、 The PIN shall be as shown in the following example: 5962 - 91664 01 H X X Federal RHA Device Device Case Lead stock class designator type class outline finish designator (see 1.2.1) (see 1.2.2) designator (see 1.2.4) (see 1.2.5) / (see 1.2.3) / Drawing number 1.2.1 Radiation hardness assurance (RHA
10、) designator. RHA marked devices shall meet the MIL-PRF-38534 specified RHA levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device. 1.2.2 Device type(s). The device type(s) identify the circuit function as follows: Device type Generic number Circuit fun
11、ction 01 MHF+2812S/883, MHF+2812SF/883 DC-DC converter, 15 W, 12 V output 02 SMHF2812S, SMHF2812SF DC-DC converter, 15 W, 12 V output 1.2.3 Device class designator. This device class designator shall be a single letter identifying the product assurance level. All levels are defined by the requiremen
12、ts of MIL-PRF-38534 and require QML Certification as well as qualification (Class H, K, and E) or QML Listing (Class G and D). The product assurance levels are as follows: Device class Device performance documentation K Highest reliability class available. This level is intended for use in space app
13、lications. H Standard military quality class level. This level is intended for use in applications where non-space high reliability devices are required. G Reduced testing version of the standard military quality class. This level uses the Class H screening and In-Process Inspections with a possible
14、 limited temperature range, manufacturer specified incoming flow, and the manufacturer guarantees (but may not test) periodic and conformance inspections (Group A, B, C and D). E Designates devices which are based upon one of the other classes (K, H, or G) with exception(s) taken to the requirements
15、 of that class. These exception(s) must be specified in the device acquisition document; therefore the acquisition document should be reviewed to ensure that the exception(s) taken will not adversely affect system performance. D Manufacturer specified quality class. Quality level is defined by the m
16、anufacturers internal, QML certified flow. This product may have a limited temperature range. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-91664 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REV
17、ISION LEVEL F SHEET 3 DSCC FORM 2234 APR 97 1.2.4 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Terminals Package style X See figure 1 8 Dual-in-line Z See figure 1 8 Flange mount 1.2.5 Lead finish. The lead finish shall
18、be as specified in MIL-PRF-38534. 1.3 Absolute maximum ratings. 1/ Input voltage range -0.5 V dc to +50 V dc Power dissipation (PD): Device type 01 6 W Device type 02 (non-RHA) . 8 W Device type 02 (RHA levels P, L and R) 9.5 W Output power . 15.30 W Lead soldering temperature (10 seconds) . +300C S
19、torage temperature range -65C to +150C 1.4 Recommended operating conditions. Input voltage range +16 V dc to +40 V dc Case operating temperature range (TC) -55C to +125C 1.5 Radiation features. Maximum total dose available (dose rate = 9 rad(Si)/s): Device type 02 (RHA levels P, L and R) 100 krad (S
20、i) 2/ 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or con
21、tract. DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-38534 - Hybrid Microcircuits, General Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - Interface Standard for Electronic Component Case Outlines. DEPARTMENT OF DEFENSE HANDBOOKS MIL-
22、HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Standard Microcircuit Drawings. (Copies of these documents are available online at http:/assist.daps.dla.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)
23、1/ Stresses above the absolute maximum ratings may cause permanent damage to the device. Extended operation at the maximum levels may degrade performance and affect reliability. 2/ These parts may be dose rate sensitive in a space environment and may demonstrate enhanced low dose rate effects. Radia
24、tion end-point limits for the noted parameters are guaranteed only for the conditions as specified in MIL-STD-883, method 1019, condition C, tested at 9 rad(Si)/s. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLASMD596291664REVF2009MICROCIRCUITHYBRIDLINEAR12VOLTSINGLECHANNELDCDCCONVERTERPDF

链接地址:http://www.mydoc123.com/p-700036.html