DLA SMD-5962-02560 REV C-2013 MICROCIRCUIT HYBRID LINEAR 12 VOLT SINGLE CHANNEL DC DC CONVERTER.pdf
《DLA SMD-5962-02560 REV C-2013 MICROCIRCUIT HYBRID LINEAR 12 VOLT SINGLE CHANNEL DC DC CONVERTER.pdf》由会员分享,可在线阅读,更多相关《DLA SMD-5962-02560 REV C-2013 MICROCIRCUIT HYBRID LINEAR 12 VOLT SINGLE CHANNEL DC DC CONVERTER.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Update drawing to the latest requirements. -sld 07-08-03 Robert M. Heber B Table II, add note to Group C end-point test parameters. Update boilerplate paragraphs. -gz 09-12-08 Charles F. Saffle C Corrected dimensions for symbols D, D2, and L1 for
2、 case outline U. Corrected dimensions for symbols D2, L, and L1 for case outline X. Corrected dimensions for symbols D, L, and L1 for case outline Y. Corrected dimensions for symbols D, D2, and L1 for case outline Z. Updated drawing paragraphs. -sld 13-01-24 Charles F. Saffle REV SHEET REV SHEET REV
3、 STATUS REV C C C C C C C C C C C C C OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 10 11 12 13 PMIC N/A PREPARED BY Steve L. Duncan DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 http:/www.landandmaritime.dla.mil/ STANDARD MICROCIRCUIT DRAWING CHECKED BY Greg Cecil THIS DRAWING IS AVAILABLE FOR USE BY ALL DEP
4、ARTMENTS APPROVED BY Raymond Monnin MICROCIRCUIT, HYBRID, LINEAR, 12 VOLT, SINGLE CHANNEL, DC/DC CONVERTER AND AGENCIES OF THE DEPARTMENT OF DEFENSE DRAWING APPROVAL DATE 02-11-21 AMSC N/A REVISION LEVEL C SIZE A CAGE CODE 67268 5962-02560 SHEET 1 OF 13 DSCC FORM 2233 APR 97 5962-E157-13 Provided by
5、 IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-02560 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL C SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope. This drawing documents five product assurance clas
6、ses as defined in paragraph 1.2.3 and MIL-PRF-38534. A choice of case outlines and lead finishes which are available and are reflected in the Part or Identifying Number (PIN). When available, a choice of radiation hardness assurance levels are reflected in the PIN. 1.2 PIN. The PIN shall be as shown
7、 in the following example: 5962 - 02560 01 H U X Federal RHA Device Device Case Lead stock class designator type class outline finish designator (see 1.2.1) (see 1.2.2) designator (see 1.2.4) (see 1.2.5) / (see 1.2.3) / Drawing number 1.2.1 Radiation hardness assurance (RHA) designator. RHA marked d
8、evices shall meet the MIL-PRF-38534 specified RHA levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device. 1.2.2 Device type(s). The device type(s) identify the circuit function as follows: Device type Generic number Circuit function 01 AFL5012S/CH DC/DC
9、 converter, 108 W, +12 V output 1.2.3 Device class designator. This device class designator shall be a single letter identifying the product assurance level. All levels are defined by the requirements of MIL-PRF-38534 and require QML Certification as well as qualification (Class H, K, and E) or QML
10、Listing (Class G and D). The product assurance levels are as follows: Device class Device performance documentation K Highest reliability class available. This level is intended for use in space applications. H Standard military quality class level. This level is intended for use in applications whe
11、re non-space high reliability devices are required. G Reduced testing version of the standard military quality class. This level uses the Class H screening and In-Process Inspections with a possible limited temperature range, manufacturer specified incoming flow, and the manufacturer guarantees (but
12、 may not test) periodic and conformance inspections (Group A, B, C, and D). E Designates devices which are based upon one of the other classes (K, H, or G) with exception(s) taken to the requirements of that class. These exception(s) must be specified in the device acquisition document; therefore th
13、e acquisition document should be reviewed to ensure that the exception(s) taken will not adversely affect system performance. D Manufacturer specified quality class. Quality level is defined by the manufacturers internal, QML certified flow. This product may have a limited temperature range. 1.2.4 C
14、ase outlines. The case outlines are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Terminals Package style U See figure 1 12 Y case configuration with leads bent upwards X See figure 1 12 Straight leads with end mounting through holes Y See figure 1 12 Straight l
15、eads with side mounting through holes Z See figure 1 12 Y case configuration with leads bent downwards 1.2.5 Lead finish. The lead finish shall be as specified in MIL-PRF-38534. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DR
16、AWING SIZE A 5962-02560 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL C SHEET 3 DSCC FORM 2234 APR 97 1.3 Absolute maximum ratings. 1/ Input voltage range -0.5 V dc to +100 V dc Lead temperature (soldering, 10 seconds) +300C Storage temperature -65C to +135C 1.4 Recommended operatin
17、g conditions. Input voltage range +30 V dc to +80 V dc Output power 2/ . 108 W Case operating temperature range (TC) . -55C to +125C 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part of this drawing to th
18、e extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-PRF-38534 - Hybrid Microcircuits, General Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standa
19、rd Microcircuits. MIL-STD-1835 - Interface Standard Electronic Component Case Outlines. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Standard Microcircuit Drawings. (Copies of these documents are available online at https:/assist.dla.mil/quick
20、search/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text of this drawing takes precedence. Nothing in this doc
21、ument, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Item requirements. The individual item performance requirements for device classes D, E, G, H, and K shall be in accordance with MIL-PRF-38534. Compliance with MIL-PRF-38534
22、shall include the performance of all tests herein or as designated in the device manufacturers Quality Management (QM) plan or as designated for the applicable device class. The manufacturer may eliminate, modify or optimize the tests and inspections herein, however the performance requirements as d
23、efined in MIL-PRF-38534 shall be met for the applicable device class. In addition, the modification in the QM plan shall not affect the form, fit, or function of the device for the applicable device class. 1/ Stresses above the absolute maximum ratings may cause permanent damage to the device. Exten
24、ded operation at the maximum levels may degrade performance and affect reliability. 2/ Derate output power linearly above case temperature +125C to 0 at +135C. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLASMD596202560REVC2013MICROCIRCUITHYBRIDLINEAR12VOLTSINGLECHANNELDCDCCONVERTERPDF

链接地址:http://www.mydoc123.com/p-698255.html