《DLA MIL-PRF-83536 5 C-2010 RELAYS ELECTROMAGNETIC ESTABLISHED RELIABILITY 4PDT LOW LEVEL TO 5 AMPERES PERMANENT MAGNET DRIVE HERMETICALLY SEALED ALL WELDED DC COILS.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-PRF-83536 5 C-2010 RELAYS ELECTROMAGNETIC ESTABLISHED RELIABILITY 4PDT LOW LEVEL TO 5 AMPERES PERMANENT MAGNET DRIVE HERMETICALLY SEALED ALL WELDED DC COILS.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、 MIL-PRF-83536/5C 08 June 2010 SUPERSEDING MIL-PRF-83536/5B 04 December 2008 PERFORMANCE SPECIFICATION SHEET RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, 4PDT, LOW LEVEL TO 5 AMPERES, PERMANENT MAGNET DRIVE, HERMETICALLY SEALED, ALL WELDED, DC COILS This specification is approved for use by all
2、 Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and the latest issue of MIL-PRF-83536. FIGURE 1. Dimensions and configurations. AMSC N/A FSC 5945 INCH-POUND Ltr Inches Millimeters Min Max Mi
3、n Max A - .810 - 20.57 B - .640 - 16.26 C .140 TYP .160 TYP 3.56 TYP 4.06 TYP D - .810 - 20.57 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-83536/5C 2 FIGURE 1. Dimensions and configurations - Continued. Provided by IHSNot for ResaleNo rep
4、roduction or networking permitted without license from IHS-,-,-MIL-PRF-83536/5C 3 FIGURE 1. Dimensions and configurations - Continued. Ltr Inches Millimeters Min Max Min Max A - .810 - 20.57 B - .640 - 16.26 C .015 .035 0.38 0.89 D .146 .166 3.71 4.22 E - 1.280 - 32.51 F 1.068 1.088 27.13 27.64 G 1.
5、052 1.072 26.72 27.23 H .140 TYP .160 TYP 3.56 TYP 4.06 TYP J .702 .722 17.83 18.34 K .140 TYP .160 TYP 3.56 TYP 4.06 TYP L .131 TYP .151 TYP 3.33 TYP 3.84 TYP M .240 .260 6.10 6.60 N .490 .510 12.45 12.95 P - .810 - 20.57 Q .123 TYP .143 TYP 3.12 TYP 3.63 TYP R 1.060 1.080 26.92 27.43 S .840 .860 2
6、1.34 21.84 T .100 .120 2.54 3.05 U .415 .435 10.54 11.05 V .840 .860 21.34 21.84 W .021 R .041 R 0.53 R 1.04 R X 490 .510 12.45 12.95 Y .240 .260 6.10 6.60 Z .137 .143 3.48 3.63 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-83536/5C 4 FIGUR
7、E 1. Dimensions and configurations - Continued Ltr Inches Millimeters Min Max Min Max A - 1.280 - 32.51 B 1.068 1.088 27.13 27.64 C 1.052 1.072 26.72 27.23 D - .810 - 20.57 E - .640 - 16.26 F .131 TYP .151 TYP 3.33 TYP 3.83 TYP G .395 .415 10.03 10.54 H .590 .610 14.99 15.49 J .123 TYP .143 TYP 3.12
8、 TYP 3.63 TYP K - .810 - 20.57 L .140 TYP .160 TYP 3.56 TYP 4.06 TYP M .015 .035 0.38 0.89 N 140 TYP .160 TYP 3.65 TYP 4.06 TYP P 1.060 1.080 26.92 27.43 Q .137 .143 3.48 3.63 R .395 .415 10.03 10.54 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MI
9、L-PRF-83536/5C 5 FIGURE 1. Dimensions and configurations - Continued. Ltr Inches Millimeters Min Max Min Max A .038 .042 0.96 1.07 B .160 .180 4.06 4.57 C .038 .042 0.96 1.07 D - .210 - 5.33 E .160 .180 4.06 4.57 F .038 .042 0.96 1.07 Provided by IHSNot for ResaleNo reproduction or networking permit
10、ted without license from IHS-,-,-MIL-PRF-83536/5C 6 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerance is .010 (0.25 mm). 4. There shall be affixed to the relay a suitable legible circuit diagram that identifies
11、each terminal location specified. 5. These relays are polarized monstable. 6. This relay shall not operate or be damaged by reverse polarity. 7. Permanent magnet drive consists of a permanent magnet with its flux path switched and combined with the electro-magnet flux. 8. Applicable to horizontal fl
12、ange mount only. The circuit diagram, manufacturers PIN, and the military PIN shall be marked on the near side. The remaining portion of the nameplate data shall be marked on the far side. 9. Applicable to horizontal flange mount only. Relays shall be marked with the manufacturers name or CAGE code
13、and date code. Marking shall be with the bottom of the print adjacent to the near side. 10. Socket pin terminals shall provide the operational, environmental, and interface characteristics to provide a reliable interconnect to gold-plated contacts. Terminal, except the polarizing pin, shall be gold-
14、plated. One system for gold plating that may be used is ASTM B488, type 3, class 1.25 with a nickel underplate of 50 to 150 microinches thick. The gold plating system shall enable the product to meet the performance requirements of this specification and shall be approved by the qualifying activity.
15、 11. Gasket shall provide a reliable seal between the relay and mating socket that will meet the environmental, operational, and interface requirements of the relay with the mating socket. The gasket shall have shore hardness 15 to 35, thickness .050 .005. Gasket material according to SAE-AMS3332 ha
16、s been considered acceptable. 12. Indicated terminal shall be identified by a contrasting bead. 13. Plane of critical motion for vibration and shock is Y-axis. FIGURE 1. Dimensions and configurations - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license fr
17、om IHS-,-,-MIL-PRF-83536/5C 7 REQUIREMENTS: Contact data: Load ratings: See table I. Low level: 10 A to 50 A at 10 mV dc to 50 mV dc or peak ac. Intermediate current: Applicable. Mixed loads: Applicable. TABLE I. Rated contact load and cycles (amperes per pole). Type of load (high level) Cycles x 10
18、3 28 V dc 115 V ac 1 phase 400 Hz 115/200 V ac 3 phase 400 Hz Resistive 100 5 5 5 Inductive 20 3 5 5 Motor 100 2 3 3 Lamp 100 1 N/A N/A Life: 100,000 cycles, unless otherwise specified (see table I). Contact voltage drop or resistance: Initial contact voltage drop: 0.100 volt maximum. Rated resistiv
19、e current at 6 V dc or peak ac. Relays shall not make or break this load. Initial contact resistance: 0.050 ohm maximum. 50 mA max at 6 V dc or peak ac. High level life (contact voltage drop): During life: 10 percent open circuit voltage maximum. After life: 0.125 volt maximum. Intermediate current
20、(contact resistance): During intermediate current: 3 ohms maximum. After intermediate current: 0.150 ohm maximum. Low level (contact resistance): During low level: 100 ohms maximum. After low level: 0.150 ohm maximum at 100 mA and 28 V dc. Contact bounce: 1.0 millisecond maximum. Contact stabilizati
21、on time: 2.5 milliseconds maximum. Overload current: 20 amperes dc, 30 amperes ac. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-83536/5C 8 Rupture current: 25 amperes dc, 40 amperes ac. Time current relay characteristics: See table II. TAB
22、LE II. Time current relay characteristics. 1/ Successive application Amperes Time 1 10 1 hour 2 15 20 seconds 3 37.5 2 seconds 4 75 .53 second 1/ All relays shall withstand overload and fault currents. Relays must be able to sustain five applications (make and carry only) of power concurrently on ad
23、jacent poles at each of four different current levels in the sequence listed in table II. Separate relays shall be tested at 28 V dc and 115/200 V ac, 400 Hz 3-phase. Cooling time between successive applications shall be 30 minutes. Tests shall be performed on both normally open and normally closed
24、contacts. There shall be no failures or evidence of welding or sticking and relays shall pass contact voltage drop at the conclusion. Coil data 1/: See table III. Operate time: 6 milliseconds maximum with rated coil voltage at 25C. 7 milliseconds maximum with rated coil voltage over the temperature
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF835365C2010RELAYSELECTROMAGNETICESTABLISHEDRELIABILITY4PDTLOWLEVELTO5AMPERESPERMANENTMAGNETDRIVEHERMETICALLYSEALEDALLWELDEDDCCOILSPDF

链接地址:http://www.mydoc123.com/p-693083.html