1、 MIL-PRF-1/1712D 16 June 2003 SUPERSEDING MIL-PRF-1/1712C 20 April 1998 PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, TRAVELING WAVE TYPE D0D-039 * This specification is approved for use by all Depart- ments and Agencies of the Department of Defense. The requirements for acquiring the electron tube
2、 described herein shall consist of this document and the latest issue of MIL-PRF-1. DESCRIPTION: Forward-wave amplifier, 2.9 to 3.1 GHz operation, 4 kw peak power output, cathode pulsed, periodic- permanent magnet focused. ABSOLUTE RATINGS: 1/ 2/ 3/ 4/ Parameter: Ef If (surge) ik ek Pd Pp Du tp tk A
3、lt (operating) Unit: V A a kv W W - s sec ft Maximum: 6.6 10 2.1 -9.5 2 750 0.03 40 - 10,000Minimum: 6.0 - 1.5 -8.5 - - 0.007 5/ - 5/ 180 - ABSOLUTE RATINGS: 1/ 2/ 3/ 4/ Coolant Coolant inlet temp Coolant Coolant Parameter: flow rate Water EG and W pressure pressure drop TA F Unit: GPM C C psig psig
4、 C GHz Maximum: 0.5 62 14 200 15 -54 F3Minimum: 0.45 - - - 10 +65 F1 PHYSICAL CHARACTERISTICS: Dimensions: See figure 1 Marking: 4/ DC connectors: See figure 1 Construction: Metal and ceramic RF connectors: See figure 1 Weight: 11 pounds, (5 kg) maximum Cooling: Liquid 6/ Mounting position: Any Focu
5、sing: Periodic permanent magnet Shelf life guarantee: 7/ _ TEST CONDITIONS: 4/ 8/ Frequncy Parameter: Ef Pd Du tp tk F F GHz Unit: V W - - s sec GHz 1 2.9 Tolerance: - max min - 1 min - 2 3.0 6.3 0.7 1.1:1 0.03 37 180 F2 3 3.1 GENERAL: Qualification: Required. _ * Replaces Varian type VAS - 805T7, I
6、TT Gilfillan Part or Identifying Number (PIN)s 145005-1, 145005-2, and tube type 8742. AMSC N/A 1 of 8 FSC 5960 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,
7、-,-MIL-PRF-1/1712D 2 TABLE I. Testing and inspection. Limits Method Requirement or test Notes Conditions Symbol Min Max Unit 1011 1027 - 1042 4258 Qualification inspection Humidity Temperature cycling (nonoperating) Vibration Shock Radio interference shielding 9/ 10/ 11/ 12/ 12/ 13/ No voltages appl
8、ied TA = -54C to +75C; 5 cycles Test condition A; 6 shocks (see figure 1) - - - - - - - - - - - - - - 1.0 - - - - mW/m21136 Rough handling 9/ - - - - 4289 1256 1261 4214 4253 4254 4253 4261 - 4256 4257 1155 - Conformance inspection, part I Heater current (nonoperating) Electrode current (cathode) El
9、ectrode voltage (cathode) Cathode emission Gain (large signal) Saturated rf power output Gain variation (large signal) Spurious output or stability Stability Input and output match (cold) Amplifier insertion loss Coolant pressure drop versus coolant flow Coolant pressure 14/ - 15/ 5/ 16/ 17/ 17/ 17/
10、 18/ 19/ 20/ 21/ - 6/ - Ef = 6.3 V tk1 = 250; tk2 = 300 F1 through F3 F1 through F3 F1 through F3 F1 through F3 F1 through F3 F = F2 Inlet temperature = 62C (max); flow rate = 0.5 GPM If ik ek ik Gls po Gls spo - VSWR Li P p 2.0 1.54 -8.5 - 37.55 4.0 - - - - 50 10 - 4.0 1.90 -9.5 0.1 - - 1.0 -40 - 2
11、.2:1 - 15 200 A A kv a dB kw dB dB - - dB psig psig 4278 1105 Conformance inspection, part 2 Phase shift Permanence of marking 22/ - ek = 50 v /ek - - - 0.3 - deg/v - See footnotes at end of table. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-
12、PRF-1/1712D 3 TABLE I. Testing and inspection - Continued. Limits Method Requirement or test Notes Conditions Symbol Min Max Unit - - 4254 Conformance inspection, part 3 Life test Life-test end point: Saturated rf power output 7/ 8/ 3/ 17/ 23/ Group D t po 1,000 3.6 - - hrs kw 1/ In addition to the
13、MIL-PRF-1 symbols, the following shall apply: EG and W .Ethylene glycol and water GPM .Gallons per minute P .Pressure ppm.Parts per million psig .Pounds per square inch, gauge ekChange in cathode pulse voltage P .Pressure drop Change in phase 2/ Cathode and one leg of heater shall be connected inter
14、nally. The helix is operated at ground potential. All voltages are referred to ground except the heater potential which is referred to the cathode. 3/ The tube shall satisfy all requirements of this tube specification sheet (TSS) when tested in a line type modulator (figure 2 or equivalent), employi
15、ng a pulse transformer (ITT Gilfillan PIN 160020, or equivalent). The line type test modulator shall utilize a pulse forming network whose impedance is within 10 percent of that shown on figure 2. 4/ A copy of the critical performance characteristics including operating voltages shall be shipped wit
16、h each tube. The operating voltages shall also be clearly indicated on the tube label and on a small decal at the collector end of each tube. Each tube delivered on the contract shall operate optimally under a single combination of discrete voltages which fall within the ranges shown under absolute
17、ratings. All operating requirements of this TSS shall be met under these specific voltages. 5/ The pulse duration (tp) shall be defined as the time interval between the first and the last instants at which the instantaneous amplitude reaches 90 percent of the peak pulse amplitude. The combination tr
18、ansition period of rise and fall times of the pulse, between the 30 and 90 percent amplitude points, shall not exceed 5.0 s with a duty cycle of 0.03. 6/ Distilled water with a maximum inlet temperature of +62C shall be used with, (1) specific resistivity maintained greater than 0.5 megohm, (2) oxyg
19、en content maintained less than 0.5 ppm, (3) an organic filter, and (4) a 3 to 4 micron filter at ambient temperatures in excess of +4C. A 60 percent ethylene glycol and 40 percent distilled water solution, by volume, with a maximum inlet temperature of +14C, with the same resistivity, oxygen conten
20、t, and filters shall be used at ambient temperatures of +4C and lower. 7/ The tubes tested and acquired in accordance with this TSS shall be capable of shelf-life for a period of 12 months after date of shipment from the manufacturers plant. Tubes placed in operation during this shelf-life period sh
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF11712D2003ELECTRONTUBETRAVELINGWAVETYPEDOD039 行进 DOD039 电子管 PDF

链接地址:http://www.mydoc123.com/p-692028.html