1、 MIL-PRF-1/1470E 27 July 2009 _ SUPERSEDING MIL-PRF-1/1470D(EC) 25 June 1999 PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, MICROWAVE (NEGATIVE GRID) TYPE 7698 This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the elec
2、tron tube described herein shall consist of this document and the latest issue of MIL-PRF-1. DESCRIPTION: Triode, planar, ceramic-metal. See figure 1. Mounting position: Any. Weight: 1.8 ounces (48 grams) nominal. ABSOLUTE RATINGS: Parameter: F Ef Eb epy Ec ib Ib ic tp Du Unit: GHz V V dc kv V dc a
3、mA dc a s - Maximum: Anode pulsed (Osc or amp) 3.0 6.3 5% 1/ 12/ - 3.5 -150 5 2/ - 2.5 3.5 0.0025 Grid pulsed (Osc or amp) 3.0 6.3 5% 1/ 12/ 2,000 - -150 5 2/ - 2.5 3.5 0.0025 Test conditions: - 6.3 600 - Adj - 25 - - - ABSOLUTE RATINGS: Parameter: Pp Pg tk TE T(anode shank) Barometric pressure redu
4、ced Cooling Unit: W W sec (min) C C mmHg - Maximum: Anode pulsed (Osc or amp) 10 2 3/ 60 250 4/ 250 4/ 35 5/ 4/ Grid pulsed (Osc or amp) 10 2 3/ 60 250 4/ 250 4/ 35 5/ 4/ Test conditions: - - 300 - - - 6/ See footnotes at end of table I. _ GENERAL: Qualification: Required. AMSC N/A FSC 5960 INCH-POU
5、ND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/1470E 2 TABLE I. Testing and inspection. Inspection Method Notes Conditions Acceptance SymbolLimits Unit MIL-STD-1311 Level 20/ Min Max Conformance inspection, part 1 Insulation of electrod
6、es 1211 7/ - Eb = Ek = 0; Ec = -500 V dc 0.65 R 50 - MegPower oscillation (pulse) 1236 8/ 9/ F = 3.0 GHz (min); epy = 3.5 kv; Ec = -1.5 V (min); Rg/Ib = 12 mA dc (max);Ef = 5.8 V 0.65 Po 6.0 - W Electrode voltage (1) (grid) 1261 6/ 0.65 Ec -4.5 -9.5 V dcTotal grid current 1266 6/ 0.65 Ic - -2.0 A dc
7、Pulsing emission 1231 - eb = ec = etd/is = 10 a; tp = 3 s (max); prr = 600 (max) 0.65 etd - 180 v Heater current 1301 - 0.65 If 1.20 1.40 A Conformance inspection, part 2 Direct-interelectrode capacitance 1331 9/ No voltages applied; use fixture in accordance with Drawing 158-JAN - Cgk Cpg Cpk 7.00
8、2.10 - 9.00 2.40 0.06 pF pF pF Resonance - 9/ 11/ No voltages applied - - - - - Electrode voltage (2) (grid) 1261 - Ec/Ib = 1.0 mA dc; Eb = 1,000 V dc - Eco - -30 V dcPower gain - 13/ F = 1,100 50 MHz; Ebb = 2,200 V dc (min); Ecc = -50 V dc; tp = 3 s (min); Du = 0.002 (min); pd = 400 w - po 1.8 - kW
9、 See footnotes at end of table. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/1470E 3 TABLE I. Testing and inspection - Continued. Inspection Method Notes Conditions AcceptanceSymbolLimits Unit MIL-STD-1311 Level 20/ Min Max Conformance i
10、nspection, part 3 Life test - 10/ Group C; t = 500 hours; filament standby; Ef = 6.3 V ac - - - - - Life-test end point - 10/ - ib - 25 % Variable-frequency vibration - 9/ 14/ 15/ 55 to 500 Hz at 10 G peak; Ec/Ib = 10 mA dc; Rp = 10,000 ohms; Ebb = 300 V dc - Ep - 250 mV acTorque - 9/ 15/ 16/ No vol
11、tages applied - - - - - Shock - 9/ 15/ 17/ 60 G peak (min); 11 2 ms; no voltages applied - - - - - Torque-and shock test end point: - Total grid current 1266 - - Ic - -10 A dcBarometric pressure, reduced 1002 15/ 18/Pressure = 35 mmHg (max); voltage = 2,000 V ac; TA = 30C 10C - - - - - 1/ The transi
12、t time heating effect of the cathode shall be compensated by a reduction in heater voltage after dynamic operation of the tubes has started. The back heating is a function of frequency, grid current, grid bias, anode current, duty cycle, and circuit design and adjustment. There is an optimum heater
13、voltage which will maintain the cathode at the correct operating temperature for a particular set of operating conditions. A maximum variation of 5 percent from optimum is permitted. No reduction in heater voltage is required up to and including 500 MHz. 2/ The regulation or series-anode-supply impe
14、dance, or both, shall limit the instantaneous peak current, with the tube considered as a short circuit, to a maximum of 10 times the specified maximum current rating. 3/ The maximum instantaneous peak grid-cathode voltage shall be within the range of +250 to -750 volts. 4/ Sufficient conduction and
15、 convection cooling shall be provided to limit the envelope and anode shank temperature to the specified maximum value under all operating conditions. Reliability will be seriously impaired if this maximum is exceeded. Where emphasis is placed on long and reliable life, lower temperatures shall be u
16、sed. 5/ Operation at this altitude is possible in a suitably designed circuit. 6/ Sufficient conduction, convection, and forced-air cooling shall be used in all electrical tests involving application of heater voltage to maintain the anode shank and seal temperatures within the specified maximum val
17、ues. 7/ All tests listed under conformance inspection, part 1, shall be performed at the conclusion of the holding period. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/1470E 4 TABLE I. Testing and inspection - Continued. 8/ The applied v
18、oltage pulse shape shall be measured with a noninductive resistor of 1,150 ohms 2 percent inserted in place of the tube. The pulse shape shall be tp = 3.0 s 10 percent, tr = 0.4 s (max), tf = 0.7 s (max). The pulse repetition rate shall be adjusted so that Du = 0.0025 5 percent with the above measur
19、ed pulse length. Test in cavity in accordance with Drawing 279-JAN. The cavity shall be connected to a load with a VSWR less than 1.5. The oscillator output coupling and the grid or cathode resistor may be adjusted for maximum power output. 9/ Other tube contact configuration may be used provided th
20、e tube contact area remains unchanged and the socket, jig, or cavity gives equal performance. Mounting of the socket, jig, or cavity may be at the option of the manufacturer. 10/ At zero hours, establish the drive conditions necessary to obtain 3.0 amperes peak anode current with an anode voltage of
21、 1,000 V dc and a bias voltage of -40 V dc. The pulse width of the modulator shall be 2 s (minimum) and the duty shall be 0.0025 maximum. With the drive level determined at zero hours, check the anode current at the end of life. The maximum allowable drop in anode current is 25 percent. 11/ Grid-ano
22、de resonance: Test in cavity in accordance with Drawing 278-JAN. Cavity shall resonate at 1,354 2 MHz with tuning lug in accordance with Drawing 277-JAN at TA = 25C 5C. Grid-cathode resonance: Test in cavity in accordance with Drawing 283-JAN. Cavity shall resonate at 1,719 2.0 MHz with tuning slug
23、in accordance with Drawing 277-JAN at TA = 25C 5C. When plotted on graphs of resonant frequency versus grid-anode capacitance and resonant frequency versus grid-cathode capacitance, the tube under test (TUT) shall be represented by a point within a parallelogram whose four corners are located by the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF11470E2009ELECTRONTUBEMICROWAVENEGATIVEGRIDTYPE7698PDF

链接地址:http://www.mydoc123.com/p-691976.html