1、 MIL-DTL-82001F 17 April 2013 SUPERSEDING MIL-C-82001E(YD)7 February 1992 DETAIL SPECIFICATION CABLE ASSEMBLY, SPECIAL PURPOSE, ELECTRICAL, INTERVEHICULAR (24 VOLT TO 12 VOLT REDUCTION) This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1
2、Scope. This specification covers one type of cable assembly used to interconnect the 24-volt (V) electrical system of a Military-type towing vehicle and the 12V electrical system of a commercial trailer or semitrailer. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are spe
3、cified in sections 3, 4, or 5 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned
4、that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this documen
5、t to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-130 Identification Marking of U.S. Military Property. MIL-STD-1916 DOD Preferred Methods for Acceptance of Product MS75
6、020 Connector, Plug, Electrical 12 Contact, Intervehicular, 24 Volt, Waterproof. (Copies of these documents are available online at http:/quicksearch.dla.mil or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) AMSC N/A FSC 2590 Comments, su
7、ggestions, or questions on this document should be addressed to: DLA Land and Maritime, Attn: VAI, P.O. Box 3990, Columbus, Ohio, 43218-3990 or emailed to FluidFlowdla.mil. Since contact information can change, you may want to verify the currency of this address information using ASSIST Online Datab
8、ase at https:/assist.dla.mil. INCH-POUND Inactive for new design after 27 April 2000. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-82001F 2 2.3 Non-Government publications. The following documents form a part of this document to the extent
9、 specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. AEROSPACE INDUSTRIES ASSOCIATION (AIA) NAS 3417 - Packaging of Electrical Cable-Cord-Wire (Copies of these documents are available online at http:/www.aia-aerospace.org or fr
10、om the Aerospace Industries Association, 1000 Wilson Boulevard, Suite 1700, Arlington, VA 22209-3901.) SAE INTERNATIONAL SAE J560 Seven-Conductor Electrical Connector for Truck-Tractor Jumper Cable. SAE J561 Electrical Terminals-Eyelet and Spade Type. SAE J1067 Seven Conductor Jacketed Cable for Tru
11、ck Trailer Connections. (Copies of these documents are available on line at www.sae.org from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, and Tel: 877-606-7323 inside USA and Canada or 724-776-4970 outside USA, email at CustomerServicesae.org.) 2.4 Order of precedence. Unles
12、s otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been ob
13、tained. 3. REQUIREMENTS 3.1 Description. The cable assembly shall consist of a 7-contact cable connector cable conforming to SAE J1067, a voltage control unit, not less than 2 feet of 7-conductor cable conforming to SAE J1067, and a 12-contact cable connector plug conforming to MS75020. The voltage
14、control unit shall provide the required reduction of voltage from a 24V tractor system for 24V or 12V trailer operation. 3.2 First article. When specified (see 6.2), the contractor shall furnish a cable assembly for first article inspection and approval (see 4.1.1 and 6.4). 3.3 Recycled, recovered,
15、or environmentally preferable materials. Recycled, recovered, or environmentally preferable materials should be used to the maximum extent possible, provided that the material meets or exceeds the operational and maintenance requirements, and promotes economically advantageous life cycle costs. 3.4
16、Construction. The cable assembly shall be constructed so that a straight pull of not less than 75 pound-force (334 N) between the jumper cable and each cable connector plug or the voltage control enclosure shall be resisted without damage to the components. Cable terminations, at cable connector plu
17、gs and at the voltage control unit, shall incorporate a strain relief which relieves all tension from the individual electrical connections. Conductor insulation shall be protected against abrasion, due to vibration or as a result of applied tension, at points of contact with conducting material. 3.
18、4.1 Cable. Jumper cable shall conform to SAE J1067. 3.4.2 Cable terminations. The 7-contact cable connector plug shall conform to SAE J560. The 12-contact cable connector plug shall be the pin type conforming to MS75020, Part or Identifying Number (PIN) MS75020-1. Conductor terminals, within the con
19、trol box, shall conform to SAE J561 with the type to be determined by the manufacturer. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-82001F 3 3.4.3 Cable dimensions. The cable shall be molded into a cylindrical coil incorporating spring-li
20、ke properties, so that following extension, the cable will retract to its original shape. The cable length from the 12-contact cable connector plug to the voltage control unit shall be not less than 2 feet (.610 m) when extended, and the coil length shall be not more than 6 inches (15.24 cm) when th
21、e cable is retracted. The cable length from the voltage control unit to the 7-contact cable connector plug shall be not less than 10 feet when extended and the coil length shall be not more than 2 feet (.610 m) when the cable is retracted. Cable shall be marked for identification by either painting
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILDTL82001F2013CABLEASSEMBLYSPECIALPURPOSEELECTRICALINTERVEHICULAR24VOLTTO12VOLTREDUCTIONPDF

链接地址:http://www.mydoc123.com/p-691089.html