DLA DSCC-DWG-86106 REV D-2001 CONNECTOR RECEPTACLE ELECTRICAL COAXIAL RADIO FREQUENCY SERIES N FOR SEMIRIGID CABLE《N型半刚性射频同轴电缆电容连接器》.pdf
《DLA DSCC-DWG-86106 REV D-2001 CONNECTOR RECEPTACLE ELECTRICAL COAXIAL RADIO FREQUENCY SERIES N FOR SEMIRIGID CABLE《N型半刚性射频同轴电缆电容连接器》.pdf》由会员分享,可在线阅读,更多相关《DLA DSCC-DWG-86106 REV D-2001 CONNECTOR RECEPTACLE ELECTRICAL COAXIAL RADIO FREQUENCY SERIES N FOR SEMIRIGID CABLE《N型半刚性射频同轴电缆电容连接器》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、REVISIONS LTR DESCRIPTION DATE APPROVED A Add source 26805. 29 Nov 1988 Randy Larson B Change vendor part numbers. Editorial changes throughout. 8 Oct 1991 Randy Larson C Add new vendor PINs and address change for CAGE 95077. 10 Nov 1994 Randy Larson D PIN and source update. 16 Nov 2001 Robert M. He
2、ber Prepared in accordance with MIL-STD-100 REV PAGE REV D D D D D D D REV STATUS OF PAGES PAGE 1 2 3 4 5 6 7 PREPARED BY PMIC N/A Ron Gary DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OHIO 43216-5000 CHECKED BY TITLE C. W. Koeller APPROVED BY R. Larson CONNECTOR, RECEPTACLE, ELECTRICAL, COAXIAL, RADIO
3、 FREQUENCY, SERIES N FOR SEMIRIGID CABLE SIZE CAGE CODE 037Z3 DWG. NO. 86106 Original date of drawing 16 May 1986 A REV D PAGE 1 OF 7 AMSC N/A 5935-E628 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.Provided by IHSNot for ResaleNo reproduction or networking permitt
4、ed without license from IHS-,-,-SIZE CAGE CODE DWG NO. 037Z3 86106 DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43216-5000 A REV D PAGE 2 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for information only. 3. Dimensions 1.750 (44.45 mm) and .940 (23.88 mm) are the largest overa
5、ll dimensions of the connector. 4. Wrench flats, when applicable, are to accommodate standard wrench opening in accordance with FED-STD-H28, appendix 10. 5. All undimensioned pictorial representations are for reference purposes only. 6. Dimension 1.750 (44.45 mm) defines the masximum length of the c
6、onnector when assembled to the appropriate cable. 7. Interface shall be in accordance with MIL-STD-348, series N, socket contact. 8. Gold plating (when required) shall be applied at least in the area of solder attachment. FIGURE 1. Dimensions and configuration. Inches mm .022 0.56 .120 3.05 .130 3.3
7、0 .250 6.35 .526 13.36 .531 13.49 .532 13.51 .543 13.79 .625 15.88 .630 16.00 .645 16.38 .745 18.92 .753 19.13 .880 22.35 .940 23.88 1.750 44.45 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SIZE CAGE CODE DWG NO. 037Z3 86106 DEFENSE SUPPLY CENTER,
8、 COLUMBUS COLUMBUS, OH 43216-5000 A REV D PAGE 3 Inches mm .100 2.54 .125 3.18 FIGURE 2. Cable strip dimensions. ENGINEERING DATA: Nominal impedance: 50 ohms. Frequency range: 0 to 18 GHz. Voltage rating: 500 volts rms maximum working voltage at sea level. 125 volts rms maximum at 70,000 feet. Tempe
9、rature rating: -65C to +105C for M17/129-RG401. -65C to +105C for M17/130-RG402, M17/130-00001, 00002, 00003. REQUIREMENTS: Requirements of drawing 84148 are applicable. Dimensions and configuration: See figure 1. Force to engage and disengage: Longitudinal force: Not applicable. Torque: 6 inch-poun
10、ds maximum. Inspection conditions: For each test of threaded coupling connector where the test is performed on mated pairs, the pairs shall be torque to 6 to 10 inch-pounds. .125 (3.18).100 (2.54)Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SIZE C
11、AGE CODE DWG NO. 037Z3 86106 DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43216-5000 A REV D PAGE 4 Mating characteristics: See MIL-STD-348 for dimensions. Center contact (socket): Oversize test pin: 0.074 diameter minimum (nonclosed entry contact only). Insertion depth: .125 minimum. Number of inse
12、rtions: 1. Insertion force test: Steel test pin diameter .066 minimum. Test pin finish: 16 microinches. Insertion force: 2 pounds maximum. Insertion depth: .125/.140. Withdrawal force test: Steel test pin diameter .063 maximum. Withdrawal force: 2 ounces minimum. Test pin finish: 16 microinches. Ins
13、ulation resistance: Method 3003 of MIL-STD-1344; 5,000 megohms minimum. Center contact retention (applicable to captivated center contact connectors only): 6 pounds minimum axial force. Corrosion (salt spray): Method 1001 of MIL-STD-1344, test condition B. Voltage standing wave ratio (VSWR): From 2.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLADSCCDWG86106REVD2001CONNECTORRECEPTACLEELECTRICALCOAXIALRADIOFREQUENCYSERIESNFORSEMIRIGIDCABLEN 刚性

链接地址:http://www.mydoc123.com/p-688833.html