《DLA A-A-59460-2000 PLATING UNIT SELECTIVE (BRUSH) PORTABLE [Superseded DLA MIL-P-80249 A CANC NOTICE 2 DLA MIL-P-80249 A VALID NOTICE 1 DLA MIL-P-80249 A DLA MIL-P-80249]《便携式选择性(电刷.pdf》由会员分享,可在线阅读,更多相关《DLA A-A-59460-2000 PLATING UNIT SELECTIVE (BRUSH) PORTABLE [Superseded DLA MIL-P-80249 A CANC NOTICE 2 DLA MIL-P-80249 A VALID NOTICE 1 DLA MIL-P-80249 A DLA MIL-P-80249]《便携式选择性(电刷.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、 INCH-POUND A-A-59460 12June2000 SUPERSEDING 22 March 1982 MIL-P-80249A COMMERCIAL ITEM DESCRIPTION PLATING UNIT, SELECTIVE (BRUSH), PORTABLE The General Services Administration has authorized the use of this commercial item description for all federal agencies. 1. SCOPE. This commercial item descri
2、ption (CID) covers portable selective (brush) plating units intended for use is such processes as electrodepositing metal in touch-up plating processes, in repair of components that cannot be disassembled for repair, and resurfacing and resizing worn surfaces. 2. CLASSIFICATION. The plating units sh
3、all be of the following types and sizes. The type and size to be furnished shall be as specified (see 7.2(b). Type I - Manual control Type II - Automatic control Beneficial comments, recommendations, additions, deletions, clarifications, etc., and any data which may improve this document should be s
4、ent to: Defense Supply Center Richmond, ATTN: DSCR-VBD, 8000 Jefferson Davis Highway, Richmond, VA 23297-5610. AMSC NIA FSC 3426 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from
5、 IHS-,-,-A-A-59460 4 5 6 Size - Sizes are shown in table I. TABLE I Plating unit sizes. o to 20 O to 25 O to 30 o to 12 o to 18 o to 18 Size Power output, Amperes Volts, direct current, minimum o to 12 o to 12 o to 10 8 9 10 I 3 I O to 15 I o to 12 O to 60 o to 100 O to 150 o to 18 o to 18 o to 18 1
6、2 I 7 I O to 50 I o to 18 O to 500 o to 18 I 11 I O to 300 I o to 18 3. SALIENT CHARACTERISTICS 3.1 General requirements. The machine shall be new and one of the manufacturers current models capable of operation in accordance with the requirements herein. All parts subject to wear, breakage, or dist
7、ortion shall be accessible for adjustment, replacement, and repair. 3.1.1 Process instruction manual. A process instruction manual shall be provided with each plating unit. The manual shall provide detail information for preparing the surfaces of metals to be plated, plating characteristics such as
8、ampere-hours, voltage range, thickness control, plating rate, current density, anode-to-cathode speed, recommended ventilation requirements, safe storage, storage and handling of solutions, and types of solutions and their intended uses. This manual is in addition to the technical information normal
9、ly required for installation, operation, and maintenance of the equipment. 3.2 Components. The plating unit shall include, as a minimum, the following components: 3.2.1 Power pack. A lightweight direct current (DC) power pack shall be provided that is designed specifically for the plating process. T
10、he power output shall not be less than that specified for each size shown in table I. 3.2.1.1 Output terminals. Unless otherwise specified (see 7.2(c), size 1 through 4 plating units shall be provided with one set of output terminals, and size 5 through 12 plating units shall be provided with two se
11、ts of output terminals. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59460 3.2.1.2 Leads. Unless otherwise specified (see 7.2(d), size 1 through 4 plating units shall be provided with one set of flexible leads, and size 5 through 12 plating
12、units shall be provided with two sets of flexible leads. Each set shall consist of a lead to the workpiece and a lead to the anode handle. Each set of leads shall be capable of handling the maximum power output of the plating unit. Each set of leads shall be constructed of the material and be of the
13、 length considered by the manufacturer as standard. 3.2.1.3 Voltmeter and ammeter. The plating unit shall be provided with a voltmeter and ammeter with scale ranges capable of reading the full voltage and ampere output of the unit. The voltmeter and ammeter shall be digital or analog as specified (s
14、ee 7.2(e). 3.2.1.4 Ampere-hour meter. When specified (see 7.2(f), size 1 through 4 plating units shall have an ampere-hour meter. Size 5 through 12 plating units shall be provided with an ampere-hour meter for plating thickness control. When provided, the ampere hour meter shall be of the reset digi
15、tal type. 3.2.2 Controls. 3.2.2.1 Manual controls (type I and type II). Unless otherwise specified (see 7.2(g), the power pack shall include, as a minimum, the following manual switches and controls: a. On-off switch. b. Reverse current switch. c. Infinitely variable voltage control. d. Ampere-meter
16、 reset switch. 3.2.2.2 Automatic control (type II). The type II plating unit shall have automatic control of the power pack ampere-hour output. Unless otherwise specified (see 7.2(h), the automatic control shall, as a minimum, be capable of the following functions: a. Program the required ampere-hou
17、r output. b. Sound an alarm when the programmed ampere-hour has been reached. c. Display programmed data and process status. 3.2.3 Anodes. If required, anodes of suitable size and shape, e.g. round, flat, concave, or convex, shall be provided as specified (see 7.2(i). The anodes shall be air cooled,
18、 flow through, or sacrificial as specified (see 7.2j). 3.2.4 Plating solutions. If required, high-speed plating solutions, specially formulated for the metal to be worked, shall be provided as specified (see 7.2(k). 3.2.5 Electrical system. Unless otherwise specified (see 7.2(1), the power pack shal
19、l conform to the American National Standards Institute/National Fire Prevention Association (ANSVNFPA) 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59460 79. Unless otherwise specified (see 7.2(m), the power pack shall operate from a 115-vol
20、t, single- phase, 60-hertz electrical circuit. 3.2.6 Electric motors. Unless otherwise specified (see 7.2(n), motors for the optional workpiece turning head and plating tools shall have sealed and permanently lubricated ball or roller bearings, shall be energy efficient, and shall conform to Nationa
21、l Electrical Manufacturers Association (NEMA) MG- 1. The motor(s) shall be totally enclosed and fan cooled (TEFC) or sealed as specified (see 7.2(0). 3.2.7 Optional accessories. 3.2.7.1 Plating station. When specified (see 7.2(p), a plating station shall be provided. The plating station shall consis
22、t of a work area, sink, air and water piping, electrical service, storage cabinets, and drawers. The work area shall be covered with a chemically resistant surface. 3.2.7.2 Mobile cart. When specified (see 7.2(q), a mobile cart shall be provided for conveyance of the plating unit power pack and to s
23、tore plating tools, solutions, and cables. 3.2.7.3 Solution pump. When specified (see 7.2(r), a solution pump shall be provided. When provided, the pump shall be a peristaltic, electric-motor-driven pump with means to adjust the flow rate and shall include all necessary hoses, couplings, and power c
24、able. The pump flow rate in gallons per minute shall be as specified (see 7.2(s). 3.2.7.4 Turning head. When specified (see 7.2(t), a turning head shall be provided. Unless otherwise specified (see 7.2(u), the turning head shall be driven by a 115-volt, single-phase, 60- hertz electric motor with a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAAA594602000PLATINGUNITSELECTIVEBRUSHPORTABLESUPERSEDEDDLAMILP80249ACANCNOTICE2DLAMILP80249AVALIDNOTICE1DLAMILP80249ADLAMILP80249

链接地址:http://www.mydoc123.com/p-687429.html