DLA A-A-50799 A-2012 CHARGER ANALYZER FOR VENTED CELL NICKEL-CADMIUM BATTERIES.pdf
《DLA A-A-50799 A-2012 CHARGER ANALYZER FOR VENTED CELL NICKEL-CADMIUM BATTERIES.pdf》由会员分享,可在线阅读,更多相关《DLA A-A-50799 A-2012 CHARGER ANALYZER FOR VENTED CELL NICKEL-CADMIUM BATTERIES.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Beneficial comments, recommendations, additions, deletions, clarifications, etc., and any data that may improve this document should be sent to: DLA Land and Maritime, ATTN: VAT, P.O. Box 3990, Columbus, OH 43218-3990, or email mailto:CircuitProtectdla.mil. Since contact information can change you m
2、ay want to verify the currency of the address information using the ASSIST Online database at https:/assist.daps.dla.mil/. AMSC N/A FSC 6130 INCH-POUND A-A-50799A 26 May 2012 SUPERSEDING A-A-50799 16 February 1982 COMMERCIAL ITEM DESCRIPTION CHARGER/ANALYZER FOR VENTED CELL NICKEL-CADMIUM BATTERIES
3、The General Services Administration has authorized the use of this commercial item description for all federal agencies. 1. SCOPE. This commercial item description (CID) covers the general requirements for a general purpose, self-contained, constant current charge type battery charger/analyzer desig
4、ned to charge nickel-cadmium (Ni-Cd) and Lead-Acid batteries. Battery chargers/analyzers covered by this CID are intended for commercial/industrial applications. 2. CLASSIFICATION/PART OR IDENTIFICATION NUMBER (PIN). This CID uses a classification system which is included in the PIN. The PIN shall b
5、e AA50799 (see 7.2). 3. SALIENT CHARACTERISTICS. 3.1 Interface and physical dimensions. Battery chargers/analyzers supplied to this CID shall be as specified herein. 3.2 Digital display capacity. Digital displays shall be provided and have the capacity to display voltage, current and battery quality
6、. 3.2.1 Current. Current shall be displayed in 99.9 full scale with an accuracy of 2 percent of full scale. 3.2.2 Individual cell. The individual cells shall be displayed in 19.9 full scale with an accuracy of 2 percent of full scale. 3.2.3 Visual status indication. A segmented bar display shall be
7、provided for visual status indication of battery. 3.3 Separate digital programmable timers. The charger and analyzer sections shall have separate digital programmable timers. 3.4 Constant current charging. Charging cycles shall be accomplished by a 2-step constant current charging method. The consta
8、nt current range this battery/analyzer shall be able to provide is from 1 Ampere (A) to 65 A, maximum. 3.5 Constant potential charge. This battery charger/analyzer shall provide constant potential charge for Lead-Acid batteries. Provided by IHSNot for ResaleNo reproduction or networking permitted wi
9、thout license from IHS-,-,-A-A-50799A 2 3.6 Constant current discharge. This battery charger/analyzer shall provide constant current discharge from 0.2 Amperes (A) to 60 A, for capacity testing. 3.7 Cell voltage balance testing and voltmeter. This battery charger/analyzer shall provide cell voltage
10、balance testing and an internal voltmeter. 3.8 Power source. This battery charger/analyzer shall operate from 110, 208 or 220 V ac, single phase, 50/60 Hertz (Hz) commercial power source with a maximum of 25 amperes current draw. 3.9 Battery temperature. While charging, the battery temperature, meas
11、ured by a thermometer in the electrolyte of the centermost cell, shall not increase more than 15 Fahrenheit (F) (9.4 Celsius (C) over temperature prior to the charging cycle. This applies to a battery which is at room temperature prior to the starting charge. 3.10 Environmental non-operating. 3.10.1
12、 Ambient temperature. The ambient temperature shall be -40F (-40C) to +159.8 F (+71 C). 3.10.2 Altitude. The non-operating altitude of this unit shall be between 0 and 50,000 feet (15,240 meters). 3.11 Environmental operating. 3.11.1 Ambient temperature. The ambient temperature shall be 32F (0C) to
13、122F (50C). 3.11.2 Altitude. The operating altitude of this unit shall be between 0 and 8,000 feet (2,438.4 meters). 3.12 Finish. All surfaces of the cabinet shall be finished with paint or coatings which are alkaline resistant. 3.13 Marking. Battery chargers/analyzers supplied to this CID shall be
14、provided with a corrosion-resistant metal nameplate in a visible and safe location on the charger cabinet exterior which shall contain, as a minimum the following information: a. Nomenclature/name b. Name of manufacturer c. Model d. Serial number e. Year of manufacture f. Part number g. Input (volts
15、) h. Input (Amperes) i. Input frequency (hertz) (NOTE: The part number marked on the unit pack shall be the CID PIN.) 3.14 Instructions. Brief instructions for operating this battery charger/analyzer shall be permanently mounted on or near the control panel. The instructions and/or diagrams shall be
16、 protected against elements that will affect their legibility. 3.15 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or environmentally preferable materials should be used to the maximum extent possible provided that the material meets or exceeds the operational and
17、 maintenance requirements, and promotes economically advantageous life cycle costs. 3.16 Workmanship. Battery charger/analyzers shall be processed in such a manner as to be uniform in quality and shall be free from other defects that will affect life, serviceability, or appearance. Provided by IHSNo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAAA50799A2012CHARGERANALYZERFORVENTEDCELLNICKELCADMIUMBATTERIESPDF

链接地址:http://www.mydoc123.com/p-686320.html