DIN ISO 2971-2015 Cigarettes and filter rods - Determination of nominal diameter - Method using a non-contact optical measuring apparatus (ISO 2971 2013)《卷烟和过滤嘴 公称直径的测定 使用激非接触式光学测量.pdf
《DIN ISO 2971-2015 Cigarettes and filter rods - Determination of nominal diameter - Method using a non-contact optical measuring apparatus (ISO 2971 2013)《卷烟和过滤嘴 公称直径的测定 使用激非接触式光学测量.pdf》由会员分享,可在线阅读,更多相关《DIN ISO 2971-2015 Cigarettes and filter rods - Determination of nominal diameter - Method using a non-contact optical measuring apparatus (ISO 2971 2013)《卷烟和过滤嘴 公称直径的测定 使用激非接触式光学测量.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、December 2015 English price group 12No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS 65.160!%Ir4“2387917www.din.deDI
2、N ISO 2971Cigarettes and filter rods Determination of nominal diameter Method using a non-contact optical measuring apparatus (ISO 2971:2013),English translation of DIN ISO 2971:2015-12Zigaretten und Filterstbe Bestimmung des Nenndurchmessers Berhrungsloses optisches Messverfahren (ISO 2971:2013),En
3、glische bersetzung von DIN ISO 2971:2015-12Cigarettes et btonnets-filtres Dtermination du diamtre nominal Mthode utilisant un instrument de mesure optique sans contact (ISO 2971:2013),Traduction anglaise de DIN ISO 2971:2015-12SupersedesDIN ISO 2971:2004-12www.beuth.deDocument comprises 22 pagesDTra
4、nslation by DIN-Sprachendienst.In case of doubt, the German-language original shall be considered authoritative.11.15A comma is used as the decimal marker. Contents PageNational foreword .31 Scope . 52 Normative references 53 Terms and definitions . 54 Principle 65 Apparatus . 66 Sampling 77 Procedu
5、re. 77.1 Preparation of test pieces 77.2 Adjustment and calibration . 87.3 Measurement 88 Expression of results 89 Repeatability and reproducibility 910 Test report . 9Annex A (normative) Calibration standards 11Annex B (informative) Measurement principle and required number of scans . 12Annex C (in
6、formative) Information on possible source of measurement error14Annex D (informative) Non-contact measurement techniques 16Annex E (informative) Alternative measurement techniques for the determination of nominal diameter of cigarettes and filter rods 19Annex F (informative) Protocol for ISO/TC 126/
7、SC 1/WG 2 interlaboratory diameter measurement uncertainty study .21DIN ISO 2971:2015-10 2 National Annex NA (informative) Bibliography.4National foreword The text of this standard (ISO 2971:2013) has been prepared by Technical Committee ISO/TC 126 “Tobacco and tobacco products”, Subcommittee SC 1 “
8、Physical and dimensional tests” (Secretariat: AFNOR, France). The responsible German body involved in its preparation was DIN-Normenausschuss Lebensmittel und landwirtschaftliche Produkte (DIN Standards Committee Food and Agricultural Products), Working Committee NA 057-04-01 AA Tabak und Tabakerzeu
9、gnisse. The DIN Standards corresponding to the International Standards referred to in this document are as follows: ISO 3402 DIN ISO 3402 ISO 5725-2 DIN ISO 5725-2 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. DIN shall not be h
10、eld responsible for identifying any or all such patent rights. Amendments This standard differs from DIN ISO 2971:2004-12 as follows: a) Clause 3 “Terms and definitions” has been revised; b) non-contact measurement techniques have been brought in line with the state of the art; c) Clause 5 “Apparatu
11、s” has been revised; d) Clause 9 “Repeatability and reproducibility” has been revised and the results of the interlaboratory study have been updated; e) the information to be given in the test report has been extended; f) Annex B “Measurement principle and required number of scans”, Annex D “Non-con
12、tact measurement techniques” and Annex F “Protocol for ISO/TC 126/SC 1/WG 2 interlaboratory diameter measurement uncertainty study” have been included. Previous editions DIN 10245: 1992-03 DIN ISO 2971: 2004-12 DIN ISO 2971:2015-12 3National Annex NA (informative) Bibliography DIN ISO 3402, Tobacco
13、and tobacco products Atmosphere for conditioning and testing DIN ISO 5725-2, Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method DIN ISO 2971:2015-10 4 Cigarettes and fil
14、ter rods Determination of nominal diameter Method using a non-contact optical measuring apparatus1 ScopeThis International Standard specifies a non contact, optical method of gauging for determination of the mean, minimum and maximum diameters and the ovality (or roundness) of rod-shaped objects wit
15、h a nominally circular or oval cross section that is convex curvilinear. The method is applicable, in particular, to cigarettes and filter rods.NOTE 1 Non-contact measurement techniques are discussed in Annex D.NOTE 2 Alternative contact or pneumatic methods may be used but should be considered as s
16、econdary methods and do not come within the scope of the standard. These alternative measurement techniques are discussed in Annex E.2 Normative referencesThe following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated re
17、ferences, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.ISO 3402, Tobacco and tobacco products Atmosphere for conditioning and testingISO 5725-2:1994, Accuracy (trueness and precision) of measurement methods a
18、nd results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method3 Terms and definitionsFor the purposes of this International Standard, the following terms and definitions apply.3.1diameterarithmetical mean value of n apparent diameters meas
19、ured on a test piece following the method specified in this International Standard, which represents the diameter of a circle with the same circumference as the perimeter of the sample being measured, provided that the boundary of its cross section is convexNote 1 to entry: The result of the measure
20、ment can be affected by n, the number of readings taken.3.2convex cross sectiona cross section where the straight line between any two points from the section is also included within the section3.3perimeterlength of the line that is the boundary of the cross sectionNote 1 to entry: Errors will exist
21、 in the estimated value of the perimeter if the sample is not circular. The error will increase as the ovality increases.3.4circumferenceperimeter of a circular cross sectionDIN ISO 2971:2015-12 53.5minimum diameterminimum value obtained from the results of n individual readings performed on a test
22、piece3.6maximum diametermaximum value obtained from the results of n individual readings performed on a test piece3.7absolute ovalityexpression of the out-of-roundness of a rod-like test piece, which is obtained from the arithmetic difference between the maximum and minimum diameters obtained from n
23、 individual readings3.8relative ovalityratio of the absolute ovality and the diameter, expressed as a percentage3.9relative roundness100 minus relative ovalityNote 1 to entry: Caution should be exercised in interpreting maximum diameters, absolute ovality, relative ovality and relative roundness as
24、these can be affected by the quality of the gum line (raised laps) or other product defects, generating erroneous individual readings.4 PrincipleThe principle of measurement of the mean diameter of a shape having a convex cross section follows the generalization of Barbiers Theorem, which states tha
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DINISO29712015CIGARETTESANDFILTERRODSDETERMINATIONOFNOMINALDIAMETERMETHODUSINGANONCONTACTOPTICALMEASURINGAPPARATUSISO29712013

链接地址:http://www.mydoc123.com/p-684456.html