DIN EN 62439-7 Berichtigung 1-2016 Industrial communication networks - High availability automation networks - Part 7 Ring-based Redundancy Protocol (RRP) (IEC 62439-7 2011) Englis.pdf
《DIN EN 62439-7 Berichtigung 1-2016 Industrial communication networks - High availability automation networks - Part 7 Ring-based Redundancy Protocol (RRP) (IEC 62439-7 2011) Englis.pdf》由会员分享,可在线阅读,更多相关《DIN EN 62439-7 Berichtigung 1-2016 Industrial communication networks - High availability automation networks - Part 7 Ring-based Redundancy Protocol (RRP) (IEC 62439-7 2011) Englis.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Mrz 2016 DKE Deutsche Kommission Elektrotechnik Elektronik Informationstechnik in DIN und VDEPreisgruppe 99DIN Deutsches Institut fr Normung e. V. Jede Art der Vervielfltigung, auch auszugsweise, nur mit Genehmigung des DIN Deutsches Institut fr Normung e. V., Berlin, gestattet.ICS 35.110!%LY“241549
2、8www.din.deDEs wird empfohlen, auf der betroffenen Norm einen Hinweis auf diese Berichtigung zu machen.DIN EN 62439-7 Berichtigung 1Industrielle Kommunikationsnetze Hochverfgbare Automatisierungsnetze Teil 7: Protokoll fr ringbasierte Redundanz (RRP) (IEC 624397:2011);Englische Fassung EN 624397:201
3、2,Berichtigung zu DIN EN 624397:201208; (IECCor.:2015 zu IEC 624397:2011)Industrial communication networks High availability automation networks Part 7: Ringbased Redundancy Protocol (RRP) (IEC624397:2011); English version EN 624397:2012,Corrigendum to DIN EN 624397:201208; (IECCor.:2015 to IEC 6243
4、97:2011)Rseaux de communication industriels Rseau de haute disponibilit pour lautomation Partie 7: Protocole de redondance pour rseau en anneau (RRP) (IEC624397:2011); Version anglaise EN 624397:2012,Corrigendum DIN EN 624397:201208; (IECCor.:2015 la IEC 624397:2011)Alleinverkauf der Normen durch Be
5、uth Verlag GmbH, 10772 Berlin www.beuth.deGesamtumfang 8 SeitenDIN EN 62439-7 Ber 1:2016-03 2 Fr diese Berichtigung ist das nationale Arbeitsgremium K 956 Feldbus“ der DKE Deutsche Kommission Elektrotechnik Elektronik Informationstechnik in DIN und VDE (www.dke.de) zustndig. In DIN EN 62439-7:2012-0
6、8 sind aufgrund der internationalen Berichtigung (IEC-Corrigendum Mai 2015 zu IEC 62439-7:2011) folgende Korrekturen vorzunehmen: Ersetze den Text von Abschnitt 10 durch folgenden (die berichtigten Textstellen sind grau hinterlegt): 10 RRP Management Information Base (MIB) - * IEC-62439-7-MIB DEFINI
7、TIONS := BEGIN - * - Imports - * IMPORTS OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Counter32, Unsigned32, Counter64, VISIBLE-STRING, INTEGER FROM SNMPv2-SMI Boolean FROM HOST-RESOURCES-MIB MacAddress FROM BRIDGE-MIB iso FROM RFC1155-SMI; - * - Declaration of TIMEOFDAY - * TIMEOFDAY := TEXTUAL-CONVENT
8、ION STATUS current DESCRIPTION “ The IEC 61158-5-21 defines the structure of the TIMEOFDAY as a data type numeric identifier 12. “ SYNTAX VISIBLE STRING (SIZE (6) - * - Root OID - * iec62439 MODULE-IDENTITY LAST-UPDATED “201306110000Z“ - June 11, 2013 ORGANIZATION “IEC/SC 65C“ CONTACT-INFO “ Interna
9、tional Electrotechnical Commission IEC Central Office 3, rue de Varembe P.O. Box 131 CH - 1211 GENEVA 20 Switzerland Phone: +41 22 919 02 11 Fax: +41 22 919 03 00 email: infoiec.ch “ DESCRIPTION “ This MIB module defines the Network Management interfaces for the Redundancy Protocols defined by the I
10、EC standard 62439. “ DIN EN 62439-7 Ber 1:2016-03 3 REVISION “201306110000Z“ - June 11, 2013 DESCRIPTION “ Consistency adjustment with other parts of IEC 62439 “ REVISION “200811100000Z“ - November 10, 2008 DESCRIPTION “ Seperation of IEC 62439 into a suite of documents. This MIB applies to IEC 6243
11、9-7, added RRP functionality. “ REVISION “200708240000Z“ - August 24, 2007 DESCRIPTION “ Initial version of the Network Management interface for the Ring-based Redundancy Protocol “ := IEC 62439 - * - Redundancy Protocols - * mrp OBJECT IDENTIFIER := iec62439 1 prp OBJECT IDENTIFIER := iec62439 2 cr
12、p OBJECT IDENTIFIER := iec62439 3 brp OBJECT IDENTIFIER := iec62439 4 drp OBJECT IDENTIFIER := iec62439 5 rrp OBJECT IDENTIFIER := iec62439 6 - * - Objects of the RRP Network Management - * ServiceID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS mandatory DESCRIPTION “ specifies informa
13、tion sufficient for local identification of the RRP device that will convey the service “ := rrp 1 InvokeID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS mandatory DESCRIPTION “ specifies the invocation of the service “ := rrp 2 DeviceAddress OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-w
14、rite STATUS mandatory DESCRIPTION “ specifies the value for the RRP device address “ := rrp 3 DeviceFlags OBJECT-TYPE SYNTAX BITS DeviceAddressCollision(0), DeviceStateChanged(1) MAX-ACCESS read-only STATUS mandatory DESCRIPTION “ specifies the flags for events that occurred in a local device “ := r
15、rp 4 DIN EN 62439-7 Ber 1:2016-03 4 DeviceState OBJECT-TYPE SYNTAX INTEGER Invalid(0), SA(1), LNM(2), GD(3), RNMP(4), RNMS(5) MAX-ACCESS read-only STATUS mandatory DESCRIPTION “ specifies the device state of the RRP device “ := rrp 5 DeviceUID OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS
16、 mandatory DESCRIPTION “ specifies the unique 8-octet identification that identifies a RRP device in a network “ := rrp 6 DeviceUIDRport1 OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS mandatory DESCRIPTION “ specifies the UID of the device that is linked through the R-port1 “ := rrp 7 Dev
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DINEN624397BERICHTIGUNG12016INDUSTRIALCOMMUNICATIONNETWORKSHIGHAVAILABILITYAUTOMATIONNETWORKSPART7RINGBASEDREDUNDANCYPROTOCOLRRPIEC6243972011ENGLISPDF

链接地址:http://www.mydoc123.com/p-678107.html