DIN EN 16447-2014 Explosion isolation flap valves German version EN 16447 2014《爆炸阻隔瓣阀 德文版本EN 16447-2014》.pdf
《DIN EN 16447-2014 Explosion isolation flap valves German version EN 16447 2014《爆炸阻隔瓣阀 德文版本EN 16447-2014》.pdf》由会员分享,可在线阅读,更多相关《DIN EN 16447-2014 Explosion isolation flap valves German version EN 16447 2014《爆炸阻隔瓣阀 德文版本EN 16447-2014》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、September 2014Translation by DIN-Sprachendienst.English price group 11No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).I
2、CS 23.060.50; 13.230!%:I“2239638www.din.deDDIN EN 16447Explosion isolation flap valves;English version EN 16447:2014,English translation of DIN EN 16447:2014-09Rckschlagklappen zur explosionstechnischen Entkopplung;Englische Fassung EN 16447:2014,Englische bersetzung von DIN EN 16447:2014-09Vanne cl
3、apet disolation dexplosion;Version anglaise EN 16447:2014,Traduction anglaise de DIN EN 16447:2014-09www.beuth.deIn case of doubt, the German-language original shall be considered authoritative.Document comprises 18 pages08.14 DIN EN 16447:2014-09 2 A comma is used as the decimal marker. National fo
4、reword This standard includes safety requirements. This document (EN 16447:2014) has been prepared by Technical Committee CEN/TC 305 “Potentially explosive atmospheres Explosion prevention and protection” (Secretariat: DIN, Germany). The responsible German body involved in its preparation was the No
5、rmenausschuss Sicherheitstechnische Grundstze (DIN Standards Committee Safety Design Principles), Working Committee NA 095-02-01 AA Explosionsschutzeinrichtungen (auer Flammendurchschlagsicherungen). EN 16447July 2014 ICS 13.230; 23.060.50 English Version Explosion isolation flap valves Vanne clapet
6、 disolation dexplosion Rckschlagklappen zur explosionstechnischen EntkopplungThis European Standard was approved by CEN on 28 May 2014. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national
7、standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version
8、in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech
9、 Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey andUnited Kingdom. CEN-
10、CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2014 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 16447:2014 EEUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGEUROPEA
11、N STANDARDNORME EUROPENNEEUROPISCHE NORMEN 16447:2014 (E) 2 Contents Page Foreword 3 1 Scope 4 2 Normative references 4 3 Terms and definitions .5 4 Explosion isolation flap valves 6 4.1 General 6 4.2 Mechanical integrity 6 5 Experimental testing of efficacy and mechanical integrity .6 5.1 General 6
12、 5.2 Test Modules 7 5.2.1 General 7 5.2.2 Module A: Explosion resistance testing .7 5.2.3 Module B: Flame transmission testing 8 5.2.4 Module C: Functional testing .9 5.3 Testing report 12 6 Information for use . 13 7 Marking 14 Annex ZA (informative) Relationship between this European Standard and
13、the Essential Requirements of EU Directive 94/9/EC . 15 Bibliography . 16 DIN EN 16447:2014-09EN 16447:2014 (E) 3 Foreword This document (EN 16447:2014) has been prepared by Technical Committee CEN/TC 305 “Potentially explosive atmospheres - Explosion prevention and protection”, the secretariat of w
14、hich is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by January 2015 and conflicting national standards shall be withdrawn at the latest by January 2015. Attention is drawn to the pos
15、sibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade
16、 Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bo
17、und to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portug
18、al, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. DIN EN 16447:2014-09EN 16447:2014 (E) 4 1 Scope This European Standard describes the general requirements for flap valves used for dust explosion isolation. An explosion isolation flap valve is a protective s
19、ystem, which prevents a dust explosion from propagating via connecting pipes or ducts into other parts of apparatus or plant areas. An explosion isolation flap valve can only stop the propagation of a dust explosion when it propagates against the direction of the normal process flow. It does not sto
20、p explosions running in the normal process flow direction. This European Standard specifies methods for evaluating the efficacy of explosion isolation flap valves. This European Standard is applicable only to explosion isolation flap valves which are intended to avoid explosion propagation from a ve
21、ssel, into other parts of the installation via connecting pipes or ducts. The standard covers isolation of such vessels that are protected by explosion venting (including flameless venting), explosion suppression or explosion resistant design. NOTE 1 This standard is only applicable to cases where t
22、he explosion starts in a vessel and not in pipes or ducting. Explosion isolation flap valves are not designed to prevent the transmission of fire or burning powder transported by the normal process flow. NOTE 2 It is necessary to take this into account in risk assessments. This European Standard is
23、only applicable for dust explosions. This European Standard is not applicable for explosions of materials listed below, or for mixtures containing some of those materials: a) gases, vapours and hybrid mixtures; b) chemically unstable substances; c) explosive substances; d) pyrotechnic substances. 2
24、Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendme
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DINEN164472014EXPLOSIONISOLATIONFLAPVALVESGERMANVERSIONEN164472014 爆炸 阻隔 德文 版本 EN164472014PDF

链接地址:http://www.mydoc123.com/p-672903.html