DIN EN 16016-2-2012 Non destructive testing - Radiation methods - Computed tomography - Part 2 Principle equipment and samples German version EN 16016-2 2011《非破坏性试验 辐射方法 计算机断层扫描 第2.pdf
《DIN EN 16016-2-2012 Non destructive testing - Radiation methods - Computed tomography - Part 2 Principle equipment and samples German version EN 16016-2 2011《非破坏性试验 辐射方法 计算机断层扫描 第2.pdf》由会员分享,可在线阅读,更多相关《DIN EN 16016-2-2012 Non destructive testing - Radiation methods - Computed tomography - Part 2 Principle equipment and samples German version EN 16016-2 2011《非破坏性试验 辐射方法 计算机断层扫描 第2.pdf(23页珍藏版)》请在麦多课文档分享上搜索。
1、January 2012 Translation by DIN-Sprachendienst.English price group 13No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).IC
2、S 19.100!$y+I“1860838www.din.deDDIN EN 16016-2Non destructive testing Radiation methods - Computed tomography Part 2: Principle, equipment and samplesEnglish translation of DIN EN 16016-2:2012-01Zerstrungsfreie Prfung Durchstrahlungsverfahren - Computertomografie Teil 2: Grundlagen, Gerte und Proben
3、Englische bersetzung von DIN EN 16016-2:2012-01Essais non destructifs Mthodes par rayonnements - Tomographie numrise Partie 2: Principes, quipements et chantillonsTraduction anglaise de DIN EN 16016-2:2012-01www.beuth.deDocument comprises pagesIn case of doubt, the German-language original shall be
4、considered authoritative.2301.12 DIN EN 16016-2:2012-01 2 A comma is used as the decimal marker. National foreword This standard has been prepared by Technical Committee CEN/TC 138 “Non-destructive testing” (Secretatariat: AFNOR, France). The responsible German body involved in its preparation was t
5、he Normenausschuss Materialprfung (Materials Testing Standards Committee), Working Committee NA 062-08-22 AA Durchstrahlungsprfung und Strahlenschutz. EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 16016-2 August 2011 ICS 19.100 English Version Non destructive testing - Radiation methods - Com
6、puted tomography - Part 2: Principle, equipment and samples Essais non destructifs - Mthodes par rayonnements - Tomographie numrise - Partie 2 : Principes, quipementset chantillons Zerstrungsfreie Prfung - Durchstrahlungsverfahren - Computertomografie - Teil 2: Grundlagen, Gerte und Proben This Euro
7、pean Standard was approved by CEN on 29 July 2011. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references conc
8、erning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member in
9、to its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Irel
10、and, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 1
11、7, B-1000 Brussels 2011 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 16016-2:2011: EEN 16016-2:2011 (E) 2 Contents Page Foreword 3Introduction .41 Scope 52 Normative references 53 Terms and definitions .54 General principles54.1
12、 Basic principles .54.2 Advantages of CT 54.3 Limitations of CT64.4 Main CT process steps 64.4.1 Acquisition .64.4.2 Reconstruction .74.4.3 Visualisation and analysis 74.5 Artefacts in CT images 85 Equipment and apparatus .85.1 General 85.2 Radiation sources 95.3 Detectors . 105.4 Manipulation 105.5
13、 Acquisition, reconstruction, visualisation and storage system 106 CT system stability . 116.1 General . 116.2 X-Ray Stability . 116.3 Manipulator stability . 117 Geometric alignment 128 Sample considerations 128.1 Size and shape of sample 128.2 Materials (including table voltage / thickness of pene
14、tration) . 12Annex A (informative) CT system components 15A.1 Radiation sources . 15A.1.1 Open Tube X-ray sets . 15A.1.2 Sealed Tube X-ray Sets 16A.1.3 Linear Accelerators 16A.1.4 X-ray target assemblies . 17A.2 Detectors . 18A.2.1 Ionisation detectors 18A.2.2 Scintillation detectors 18A.2.3 Semicon
15、ductor detectors 19A.3 Manipulation 19A.4 Acquisition, reconstruction, visualisation and storage system 19A.4.1 Acquisition system . 19A.4.2 Reconstruction system 20A.4.3 Visualisation system 20A.4.4 Storage system . 20Bibliography . 21DIN EN 16016-2:2012-01 EN 16016-2:2011 (E) 3 Foreword This docum
16、ent (EN 16016-2:2011) has been prepared by Technical Committee CEN/TC 138 “Non-destructive testing”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by Febr
17、uary 2012, and conflicting national standards shall be withdrawn at the latest by February 2012. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such pate
18、nt rights. EN 16016 consists of the following parts: Non destructive testing Radiation methods Computed tomography Part 1: Terminology; Non destructive testing Radiation methods Computed tomography Part 2: Principle, equipment and samples; Non destructive testing Radiation methods Computed tomograph
19、y Part 3: Operation and interpretation; Non destructive testing Radiation methods Computed tomography Part 4: Qualification. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belg
20、ium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. DIN EN 16
21、016-2:2012-01 EN 16016-2:2011 (E) 4 Introduction This document gives guidelines for the general principles of X-ray computed tomography (CT) applicable to industrial imaging (in the context of this standard, industrial means non-medical applications); it also gives a consistent set of CT performance
22、 parameter definitions, including how these performance parameters relate to CT system specifications. This document deals with computed axial tomography and excludes other types of tomography such as translational tomography and tomosynthesis. DIN EN 16016-2:2012-01 EN 16016-2:2011 (E) 5 1 Scope Th
23、is European Standard specifies the general principles of computed tomography (CT), the equipment used and basic considerations of sample, materials and geometry. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, on
24、ly the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 473, Non-destructive testing Qualification and certification of NDT personnel General principles EN 16016-1:2011, Non destructive testing Radiation method Comput
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DINEN1601622012NONDESTRUCTIVETESTINGRADIATIONMETHODSCOMPUTEDTOMOGRAPHYPART2PRINCIPLEEQUIPMENTANDSAMPLESGERMANVERSIONEN1601622011

链接地址:http://www.mydoc123.com/p-672599.html