DIN EN 15882-4-2012 Extended application of results from fire resistance tests for service installations - Part 4 Linear joint seals German version EN 15882-4 2012《服务装置用耐火性试验结果的扩展应.pdf
《DIN EN 15882-4-2012 Extended application of results from fire resistance tests for service installations - Part 4 Linear joint seals German version EN 15882-4 2012《服务装置用耐火性试验结果的扩展应.pdf》由会员分享,可在线阅读,更多相关《DIN EN 15882-4-2012 Extended application of results from fire resistance tests for service installations - Part 4 Linear joint seals German version EN 15882-4 2012《服务装置用耐火性试验结果的扩展应.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、-XO7UDQVODWLRQE,16SUDFKHQGLHQVW(QJOLVKSULFHJURXS1RSDUWRIWKLVWUDQVODWLRQPDEHUHSURGXFHGZLWKRXWSULRUSHUPLVVLRQRI,1HXWVFKHV,QVWLWXWIU1RUPXQJH9%HUOLQ%HXWK9HUODJ*PE+%HUOLQ*HUPDQKDVWKHHFOXVLYHULJKWRIVDOHIRU*HUPDQ6WDQGDUGV ,11RUPHQ , prEN 15882-2, Extended application of results from fire resistance tests f
2、or service installations Part 2: Dampers; EN 15882-3, Extended applications of results from fire resistance tests for service installations Part 3: Penetration seals; EN 15882-4, Extended application of results from fire resistance tests for service installations Part 4: Linear joint seals. Accordin
3、g to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
4、 Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. DIN EN 15882-4:2012-07 EN 15882-4:2012 (E) 4 1 Scope This European standard specifies rules and prescribes the methodology for the pre
5、paration of extended application reports for linear joint sealing systems tested in accordance with EN 1366-4. The field of the extended application reports is additional to the direct field of application given in EN 1366-4. It may be applied to or based on a single test, or a number of tests, whic
6、h provide the relevant information for the formulation of an extended application. Mechanical metal seals are not part of the scope of this European Standard. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for it
7、s application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1363-1:1999, Fire resistance tests Part 1: General requirements EN 1363-2:1999, Fire resistance tests Part 2: Alternative
8、and additional procedures EN 1366-4:2006+A1:2010, Fire resistance tests for service installations Part 4: Linear joint seals EN 13501-1:2007+A1:2009, Fire classification of construction products and building elements Part 1: Classification using data from reaction to fire tests EN 13501-2:2007+A1:20
9、09, Fire classification of construction products and building elements Part 2: Classification using data from fire resistance tests, excluding ventilation services EN ISO 13943:2010, Fire safety Vocabulary (ISO 13943:2008) 3 Terms and definitions For the purposes of this document the terms and defin
10、itions given in EN 1363-1:1999, EN 1363-2:1999, EN 1366-4:2006+A1:2010, EN 13501-1:2007+A1:2009, EN 13501-2:2007+A1:2009 and EN ISO 13943:2010, and the following apply: 3.1 fabric seal seal comprised of a woven fabric, usually glass cloth or similar, which may be used in a combination with other mat
11、erial, such as metal facings, etc. to provide a composite seal 3.2 foam seal seal made from a one, two or three component expanding foam (expands during application), applied in-situ 3.3 joint depth overall distance between the exposed and unexposed faces across the thickness of the separating eleme
12、nt Note 1 to entry: See Figure 1. 3.4 joint face framing additional substrate incorporated between the supporting construction and the joint seal DIN EN 15882-4:2012-07 EN 15882-4:2012 (E) 5 3.5 joint width distance between the two adjacent faces of the building element(s) Note 1 to entry: See Figur
13、e 1. 3.6 mineral wool seal seal comprised mostly or entirely of glass, stone, slag or ceramic wool, which is either faced/coated or non-faced/coated 3.7 mortar seal seal comprising a cementitious or gypsum based compound together with other filler materials, usually mixed on site with water to achie
14、ve the required workability 3.8 movement joint joint between adjacent building elements or within a building element designed to accommodate a degree of movement greater than 7,5% (such as deflection, thermal movement or seismic) 3.9 non-movement joint joint between adjacent building elements or wit
15、hin a building element not designed to accommodate movement greater than 7,5% (such as those designed to accommodate construction tolerances or irregularities of fit) 3.10 seal depth shortest distance between the exposed and unexposed surfaces of the seal Note 1 to entry: See Figure 1. 3.11 seal wid
16、th width of the seal in the non-installed condition (for uncompressed solid seals, see Figure 1, detail A) or the width of the installed seal where it is equal to or different from the joint width (e.g. overlap) (see Figure 1, details B and C) 3.12 sealant seal seal formed from materials such as acr
17、ylics, silicone, oil-based products (mastic, putty), foamed in-situ, normally in conjunction with a backing material and inserted into the joint 3.13 strip seal pre-formed seal normally inserted into the joint and held in place by friction or by means of an adhesive Note 1 to entry: Strip seals may
18、also include impregnated or multi component (composite, laminated) seals such as a combination of foam tape with strips of intumescent material. 3.14 surface mounted strip surface mounted seal applied over the joint to completely cover and overlap the joint and usually mechanically fixed to the surf
19、ace of the building element DIN EN 15882-4:2012-07 EN 15882-4:2012 (E) 6 A 1534B 1234C 1345Key 1 Seal width 2 Direction of compression 3 Joint depth 4 Joint width 5 Seal depth Linear joint seal Figure 1 Description of seal depth, joint depth and joint width for different types of seals DIN EN 15882-
20、4:2012-07 EN 15882-4:2012 (E) 7 Key Joint face framing Figure 2 Examples for a joint face framing 4 Extended application principles 4.1 General Due to the diverse nature of materials and constructions used to seal linear joints or construction joints in fire resistant separating elements, it has bee
21、n necessary to separate the extended application principles into generic seal types. Permitted variations may be used alone or in combination, unless stated otherwise. Principles common to all generic seal types are given in 4.2. Principles and guidance relating to each specific generic joint type a
22、re given in Annex A of this European Standard. Variables for each seal type which require consideration, are included in this report. These are as follows: separating element; joint width/seal width; joint depth/seal depth; seal position in relation to the exposed face; orientation (see EN 1366-4);
23、whether the joint is a movement or non-movement joint. Each sub-clause gives the possible variation and the rule relating to the variation. The following rules are considered applicable to joint assemblies tested either with or without induced movement. 4.2 Principles common to all generic seal type
24、s 4.2.1 General The rules given in the following sub-clauses are applicable to all generic linear joint seal types incorporated within Annex A, unless stated otherwise in the specific section. DIN EN 15882-4:2012-07 EN 15882-4:2012 (E) 8 4.2.2 Seal material (primary generic linear joint seal materia
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便