《DIN EN 15869-1-2010 Inland navigation vessels - Electrical shore connection three phase current 400 V up to 63 A 50 Hz - Part 1 General requirements German version EN 15869-1 2010《.pdf》由会员分享,可在线阅读,更多相关《DIN EN 15869-1-2010 Inland navigation vessels - Electrical shore connection three phase current 400 V up to 63 A 50 Hz - Part 1 General requirements German version EN 15869-1 2010《.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、June 2010 Translation by DIN-Sprachendienst.English price group 8No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS 47
2、.020.60; 47.060!$i“1700427www.din.deDDIN EN 15869-1Inland navigation vessels Electrical shore connection, three phase current 400 V, up to 63 A,50 Hz Part 1: General requirementsEnglish translation of DIN EN 15869-1:2010-06Fahrzeuge der Binnenschifffahrt Elektrischer Landanschluss, Drehstrom 400 V,
3、bis 63 A, 50 Hz Teil 1: Allgemeine AnforderungenEnglische bersetzung von DIN EN 15869-1:2010-06Bateaux de navigation intrieure Connexion au rseau lectrique terrestre, courant triphas 400 V, 63 A, 50 Hz Partie 1: Exigences gnralesTraduction anglaise de DIN EN 15869-1:2010-06www.beuth.deDocument compr
4、ises pagesIn case of doubt, the German-language original shall be considered authoritative.120 .10 5DIN EN 15869-1:2010-06 A comma is used as the decimal marker. National foreword This standard has been prepared by Technical Committee CEN/TC 15 “Inland navigation vessels” (Secretariat: DIN, Germany)
5、. The responsible German body involved in its preparation was the Normenstelle Schiffs- und Meerestechnik (Shipbuilding and Marine Technology Standards Committee), Joint Committee GA BWH/NSMT NA 132-07-01 AA Binnenschifffahrt, Wasserfahrzeuge und Hafenanlagen. Attention is drawn to the possibility t
6、hat some of the elements of this document may be the subject of patent rights. DIN shall not be held responsible for identifying any or all such patent rights. 2 EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 15869-1 February 2010 ICS 47.020.60; 47.060 English Version Inland navigation vessels
7、 - Electrical shore connection, three phase current 400 V, up to 63 A, 50 Hz - Part 1: General requirements Bateaux de navigation intrieure - Connexion au rseau lectrique terrestre, courant triphas 400 V, 63 A, 50 Hz -Partie 1: Exigences gnrales Fahrzeuge der Binnenschifffahrt - Elektrischer Landans
8、chluss, Drehstrom 400 V, bis 63 A, 50 Hz - Teil 1: Allgemeine Anforderungen This European Standard was approved by CEN on 25 December 2009. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a natio
9、nal standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in a
10、ny other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, D
11、enmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMAL
12、ISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2010 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 15869-1:2010: EEN 15869-1:2010 (E) 2 Contents Page Foreword3 Introduction .4 1 Scope 5
13、 2 Normative references 5 3 Terms and definitions .5 4 Requirements.5 4.1 Components.5 4.2 Characteristic values.6 4.3 Readiness for operation7 4.4 Consumption recording and settlement .7 4.5 Deviations from 4.3 and 4.4 7 Annex A (informative) Electrical power-supply stations Possible payment method
14、s 8 A.1 Transponder card Prepaid card.8 A.2 Money card .8 A.3 EC-card (Giro card)/credit card 9 A.4 GPRS fleet cards9 DIN EN 15869-1:2010-06 EN 15869-1:2010 (E) 3 Foreword This document (EN 15869-1:2010) has been prepared by Technical Committee CEN/TC 15 “Inland navigation vessels”, the secretariat
15、of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by August 2010, and conflicting national standards shall be withdrawn at the latest by August 2010. EN 15869, Inland navigatio
16、n vessels Electrical shore connection Three-phase current 400 V, up to 63 A, 50 Hz comprises: Part 1: General requirements Part 2: Onshore unit, safety requirements Part 3: On-board unit, safety requirements According to the CEN/CENELEC Internal Regulations, the national standards organizations of t
17、he following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovak
18、ia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. DIN EN 15869-1:2010-06 EN 15869-1:2010 (E) 4 Introduction Inland navigation vessels are equipped with a variety of electrical loads operating at 230 V or 400 V. While underway, continuous electrical power supply is provided by the onbo
19、ard system from generators driven by diesel engines. When the vessel is berthed, these generators have to remain in operation if there is no suitable onshore power supply available. In some cases, this leads to intense noise pollution both for the crew on the vessel itself and on other vessels lying
20、 alongside and also for residents ashore. The exhaust fumes are an additional pollution factor. The electrical shore connections specified in this standard make it possible to provide the vessels with an electrical power supply while berthed and to eliminate noise and exhaust pollution. This calls f
21、or a uniform Europe-wide connection that can be activated and deactivated by the vessels crew in all ports and berths, if possible, without requiring any assistance from shore-based personnel. This standard contains electrical safety requirements for the prevention of hazards in making, using and br
22、eaking the shore connection. Furthermore, cashless settlement for the electricity used shall be possible, ideally a standard Europe-wide payment system. Electrical shore connections with a permissible current of over 63 A as used for passenger ships with a hotelling function are not covered by this
23、standard. DIN EN 15869-1:2010-06 EN 15869-1:2010 (E) 5 1 Scope This European Standard specifies requirements applicable to equipment for shore-to-vessel supply of three-phase 400 V electrical power up to 63 A and a frequency of 50 Hz to berthed inland navigation vessels. This part of the European St
24、andard specifies general requirements and contains information on the settlement method. 2 Normative references This document does not contain any normative references. 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 electrical shore connecti
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DINEN1586912010INLANDNAVIGATIONVESSELSELECTRICALSHORECONNECTIONTHREEPHASECURRENT400VUPTO63A50HZPART1GENERALREQUIREMENTSGERMANVERSIONEN1586912010PDF

链接地址:http://www.mydoc123.com/p-672493.html