DIN EN 14181-2015 Stationary source emissions - Quality assurance of automated measuring systems German version EN 14181 2014《固定源辐射 自动测量系统的质量保证 德文版本EN 14181-2014》.pdf
《DIN EN 14181-2015 Stationary source emissions - Quality assurance of automated measuring systems German version EN 14181 2014《固定源辐射 自动测量系统的质量保证 德文版本EN 14181-2014》.pdf》由会员分享,可在线阅读,更多相关《DIN EN 14181-2015 Stationary source emissions - Quality assurance of automated measuring systems German version EN 14181 2014《固定源辐射 自动测量系统的质量保证 德文版本EN 14181-2014》.pdf(90页珍藏版)》请在麦多课文档分享上搜索。
1、February 2015 Translation by DIN-Sprachendienst.English price group 30No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).I
2、CS 13.040.40!%?q“2285678www.din.deDDIN EN 14181Stationary source emissions Quality assurance of automated measuring systems;English version EN 14181:2014,English translation of DIN EN 14181:2015-02Emissionen aus stationren Quellen Qualittssicherung fr automatische Messeinrichtungen;Englische Fassung
3、 EN 14181:2014,Englische bersetzung von DIN EN 14181:2015-02mission des sources fixes Assurance qualit des systmes automatiques de mesurage;Version anglaise EN 14181:2014,Traduction anglaise de DIN EN 14181:2015-02SupersedesDIN EN 14181:2004-09www.beuth.deIn case of doubt, the German-language origin
4、al shall be considered authoritative.This standard has been included in the VDI/DIN Handbook on air quality, Volume 5.Document comprises 90 pages 01.15 DIN EN 14181:2015-02 2 A comma is used as the decimal marker. National foreword This document (EN 14181:2014) has been prepared by Technical Committ
5、ee CEN/TC 264 “Air quality” (Secretariat: DIN, Germany), Working Group WG 9 “Quality assurance of automated measuring systems” (Secretariat: DIN, Germany; Convenership: BSI, United Kingdom). The responsible German body involved in its preparation was the Kommission Reinhaltung der Luft im VDI und DI
6、N Normenausschuss KRdL (Commission on Air Pollution Prevention of VDI and DIN Standards Committee KRdL), Working Committee NA 134-04-03-10 UA Emissionsermittlung mit automatischen Ein-richtungen. The requirements of DIN EN 14181 for measuring emissions using automated measuring systems are supplemen
7、ted by the more detailed provisions given in VDI 3950. VDI 3950 specifies, for all plants with a continuous monitoring of emissions, the correct installation and surveillance of such systems with respect to the requirements on measurement sections and sites, the installation site, and installation o
8、f the automated measuring system, as well as the documentation of the performance of quality assurance measures. Furthermore, VDI 3950 specifies requirements and procedures for plants where DIN EN 14181 should not be fully applied where this would be unreasonable. This can include, for example, plan
9、ts within the meaning of the 1st, 27th and 31st ordinances on the implementation of the German Federal Immission Control Act (1. BImSchV, 27. BImSchV and 31. BImSchV) and plants requiring an operating permit according to 4. BImSchV, that are not covered by European regulations. The DIN Standards cor
10、responding to the International Standards referred to in this document are as follows: ISO 3534-1 DIN ISO 3534-1 ISO 11095 DIN ISO 11095 Amendments This standard differs from DIN EN 14181:2004-09 as follows: a) Subclause 5.1: a requirement has been added that in case of new installations of AMS, the
11、 AMS shall have been certified in accordance with EN 15267-1, EN 15267-2 and EN 15267-3. The description of treatment of AMS already installed at plants which have not been certified according to EN 15267-1, EN 15267-2 and EN 15267-3 has been added; b) Subclause 5.3: normative reference to EN 15259
12、has been added; c) Subclause 6.2: a recommendation has been added to perform the functional test not more than one month before parallel measurements are started. A recommendation has been added to perform the relevant steps of the functional test for measuring systems of the peripheral parameters;
13、d) Subclause 6.3: if the QAL2 is not the first QAL2 being carried out on the AMS, then an AST may be performed instead of a QAL2 provided that the SRM measured values obtained since the last AST are less than the maximum permissible uncertainty specified. If calibrated AMS measured values for water
14、vapour are available, these may be used to convert the SRM data to dry or wet basis. In case of wet abatement techniques with nearly constant water vapour concentration, conversion to dry or wet basis may be carried out using calculated water vapour values;DIN EN 14181:2015-02 3 e) Subclause 6.4.1:
15、a requirement has been added that outliers in data sets shall be identified and reported; f) Subclause 6.4.3: a new procedure for the treatment of low level clusters has been added. The criterion for the identification of a cluster has been changed from 15 % of ELV to the maximum permissible uncerta
16、inty; g) Subclause 6.5: a minimum upper limit of the valid calibration range of 20 % of ELV has been added. Treatment of exceedances of the valid calibration range in case of discontinuous plant operation or plant failures has been added; h) Subclause 6.6: the procedure has been adapted to the new p
17、rocedure for treatment of low level clusters in Subclause 6.4.3. A recommendation has been added to calibrate the peripheral AMS for oxygen and water vapour; i) Subclause 6.8: the method used to assess outliers and reasons for excluding outliers has to be presented in the QAL2 report; j) Subclause 7
18、: the ongoing quality assurance during operation (QAL3) has been editorially revised and amended. The selection and use of control charts as well as the zero and span measurements are described in much more detail; k) Subclause 7.1: if a plant is operating two independent parallel AMS then the inter
19、vals for QAL3 procedures may be extended under specified conditions to one year; l) Subclause 8.2: a clarification has been added that the testing laboratory performing the parallel measurements shall meet the requirements in Subclause 5.4; m) Subclause 8.3: a requirement has been added that outlier
20、s in data sets shall be identified and reported; n) Subclause 8.5: the table with kvand t0,95, N1values has been moved to Annex I. If the AST demonstrates that the existing calibration function is valid beyond the existing valid calibration range, the competent authority can allow the plant to exten
21、d the valid calibration range; o) Subclause 8.6: the method used to assess outliers and reasons for excluding outliers has to be presented in the QAL2 report; p) Annex A.1: functional tests are identical now for QAL2 and AST; q) Annex C.1: description of Shewhart control charts and an example have b
22、een added; r) Annex C.2: description of exponentially weighted moving average control charts and an example have been added; s) Annex E.3: an example for the calibration of an AMS in case of a low level cluster has been added; DIN EN 14181:2015-02 4 t) Annex H: the original Annex H has been deleted
23、and replaced by a new annex on the implementation of QAL1; u) Annex I (new): the table with kvand t0,95, N1values has been amended and moved from Subclause 8.5 to Annex I. Previous editions DIN EN 14181: 2004-09 DIN EN 14181:2015-02 5 National Annex NA (informative) Bibliography DIN ISO 3534-1, Stat
24、istics Vocabulary and symbols Part 1: General statistical terms and terms used in probability DIN ISO 11095, Linear calibration using reference materials VDI 3950, Stationary source emissions Quality assurance of automated measuring and electronic data evaluation systems DIN EN 14181:2015-02 6 This
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DINEN141812015STATIONARYSOURCEEMISSIONSQUALITYASSURANCEOFAUTOMATEDMEASURINGSYSTEMSGERMANVERSIONEN141812014

链接地址:http://www.mydoc123.com/p-667026.html