DIN 7865-1-2015 Elastomeric-Waterstops for sealing joints in concrete - Part 1 Shapes and dimensions《混凝土接缝用密封剂弹性止水材料 第1部分 形状和尺寸》.pdf
《DIN 7865-1-2015 Elastomeric-Waterstops for sealing joints in concrete - Part 1 Shapes and dimensions《混凝土接缝用密封剂弹性止水材料 第1部分 形状和尺寸》.pdf》由会员分享,可在线阅读,更多相关《DIN 7865-1-2015 Elastomeric-Waterstops for sealing joints in concrete - Part 1 Shapes and dimensions《混凝土接缝用密封剂弹性止水材料 第1部分 形状和尺寸》.pdf(27页珍藏版)》请在麦多课文档分享上搜索。
1、February 2015 English price group 13No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS 91.100.50!%L?“2412898www.din.de
2、DIN 7865-1ElastomericWaterstops for sealing joints in concrete Part 1: Shapes and dimensions,English translation of DIN 7865-1:2015-02ElastomerFugenbnder zur Abdichtung von Fugen in Beton Teil 1: Formen und Mae,Englische bersetzung von DIN 7865-1:2015-02Bandes de jointuration en lastomres pour ltanc
3、hisation de joints dans le bton Partie 1: Formes et dimensions,Traduction anglaise de DIN 7865-1:2015-02SupersedesDIN 78651:200802www.beuth.deDocument comprises 27 pagesDTranslation by DIN-Sprachendienst.In case of doubt, the German-language original shall be considered authoritative.04.16 DIN 7865-
4、1:2015-02 2 A comma is used as the decimal marker. Contents Page Foreword . 3 1 Scope 4 2 Normative references 4 3 Terms and definitions 4 4 Dimensions 5 4.1 Shapes and dimensions . 5 4.1.1 Elastomer waterstops with centre bulb 5 4.1.2 Elastomer waterstops without a centre bulb 6 4.1.3 Elastomer cap
5、 seals . 6 4.2 Designation 6 5 Requirements 7 5.1 Dimensions 7 5.2 Surface condition . 7 5.3 Shapes 7 6 Marking . 26 Bibliography . 27 DIN 7865-1:2015-02 3 Foreword This standard has been prepared by Working Committee NA 045-02-10 AA Fugendichtungen of DIN-Normenausschuss Kautschuktechnik (FAKAU) (D
6、IN Standards Committee Rubber Technology). It establishes the shapes and dimensions of waterstops (joint sealing strips) that represent the state of the art. The material properties specified in DIN 7865-2 are an integral part of this standard. The elastomer waterstops defined in this standard make
7、it possible to combine the products of different manufacturers to suit the particular application. The polymer is to be retained. DIN 7865 consists of the following parts under the general title Elastomer waterstops for sealing joints in concrete: Part 1: Shapes and dimensions Part 2: Material speci
8、fications and testing Part 3: Range of applications Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. DIN and/or DKE shall not be held responsible for identifying any or all such patent rights. Amendments This standard differs from
9、DIN 7865-1:2008-02 as follows: a) the standard has been editorially revised; b) Figures 1 to 35, 37 and 40 have been revised; centrelines as in DIN ISO 128-23 have been included; c) Figure 41 has been added. Previous editions DIN 7865-1: 1982-02, 2008-02 DIN 7865-1:2015-02 4 1 Scope This standard sp
10、ecifies the shapes and dimensions of elastomer waterstops, with and without steel straps, used for sealing joints in concrete. DIN 7865-1 does not give guidance on the practical application of the waterstops in construction work. DIN 18197, developed by DIN-Normenausschuss Bauwesen (NABau) (DIN Stan
11、dards Committee Building and Civil Engineering), lays down specifications for the function and construction principles of waterstops, and the corresponding selection criteria. DIN 7865-1 does not apply to elastomer waterstops with fabric reinforcement or waterstops made of other materials (e.g. ther
12、moplastic elastomers (TPE), blends with thermoplastics, etc.). It also does not apply to gaskets or strip for sealing joints in plain or reinforced concrete pipes. DIN 7865-2 applies to the material properties of elastomer waterstops. 2 Normative references The following documents, in whole or in pa
13、rt, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. DIN 7865-2, Elastomeric waterstops for sealing jo
14、ints in concrete Part 2: Material specifications and testing DIN 18197, Sealing of joints in concrete with waterstops DIN 18200, Assessment of conformity for construction products Certification of construction products by certification body DIN ISO 128-23, Technical drawings General principles of pr
15、esentation Part 23: Lines on construction drawings DIN ISO 1629, Rubber and latices Nomenclature DIN ISO 3302-1:1999-10, Rubber Tolerances for products Part 1: Dimensional tolerances (ISO 3302-1:1996) 3 Terms and definitions For the purposes of this document, the following terms and definitions appl
16、y. 3.1 elastomer polymeric material that exhibits rubber-elastic behaviour within the service temperature range SOURCE: DIN 7724:1993-04 3.2 elastomer waterstop strip made from rubber that is mixed with fillers, processing aids and vulcanizing agents and then vulcanized to become an elastomer DIN 78
17、65-1:2015-02 5 4 Dimensions 4.1 Shapes and dimensions Subclauses 4.1.1, 4.1.2 and 4.1.3 specify requirements for shapes and dimensions of elastomer waterstops. 4.1.1 Elastomer waterstops with centre bulb Shape FM: internal elastomer waterstop with centre bulb FM 200 (see Figure 1) FM 250 (see Figure
18、 2) FM 300 (see Figure 3) FM 350 (see Figure 4) FM 400 (see Figure 5) FM 500 (see Figure 6) FM 230 R (see Figure 7) FM 320 R (see Figure 8) FM 500 R (see Figure 9) Shape FMS: internal elastomer waterstop with centre bulb and steel straps FMS 350 (see Figure 10) FMS 400 (see Figure 11) FMS 500 (see F
19、igure 12) FMS 350 R (see Figure 13) FMS 400 R (see Figure 14) FMS 500 R (see Figure 15) FMS 450 RMD (see Figure 16) Shape AM: external elastomer waterstop (base seal) with centre bulb AM 250 (see Figure 17) AM 350 (see Figure 18) AM 500 (see Figure 19) Shape FM elastomer waterstops can be provided w
20、ith securing strips at the end of the profile (see Figure 36). Elastomer waterstops of shapes FM, FMS and AM can be provided with securing strips on the centre bulb (see Figure 37 and Figure 38). The centre bulb of elastomer waterstops of shapes FM and FMS can be provided with a casing of closed-cel
21、l elastomer foam (see Figure 40) or in the form of a moulded hollow core (see Figure 41). NOTE For elastomer waterstops with an encased centre bulb, the distance between the casing and the first anchor shall be 30 mm. Shape A elastomer waterstops can be provided with ribs on the base plate, anchors
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便