《DIN 51589-1-1991 Determination of water separation ability of lubricating oils and low-flammability fluids after contact with steam《第1部分 润滑油脱水能力和液体接触蒸汽后低可燃性的测定》.pdf》由会员分享,可在线阅读,更多相关《DIN 51589-1-1991 Determination of water separation ability of lubricating oils and low-flammability fluids after contact with steam《第1部分 润滑油脱水能力和液体接触蒸汽后低可燃性的测定》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、March 1991 UDC 621 392.2 : 665.765 : 620.1 : 542.93 DEUTSCHE NORM Determination of water separation ability of lubricating oils and low-flammability fluids after contact with steam DIN 51589 Part 1 Prfung von Schmierstoffen und verwandten Erzeugnissen; Bestimmung des Wasserabscheidevermgens nach Dam
2、pfbehandlung; Prfung von Schmierlen und schwerentflammbaren Flssigkeiten Supersedes August 1987 edition. Beuth Verlag GmbH. Berlin, has the exclusive right of sale for German Standards (DIN-Normen). 04.93 DIN 51 589 Engl. Price group 6 Sales No. O106 In keeping with current practice in standards pub
3、lished by the International Organization for Standardization (ISO), a comma has been used throughout as the decimal marker. Dimensions in mm 1 Scope and field of application This standard describes methods that serve to determine the water separation ability of a) lubricating oils of viscosity class
4、es up to and including IS0 VG 100 as specified in DIN 51 519, with a density of no more than 0,900 gim3 at 15 OC (method A), and to b) HFD fluids (anhydrous fluids; cf. DIN 51 502) of viscosity classes up to and including IS0 VG 46 as specified in DIN 51 519, with a density of more than 1 g/cm3 at 1
5、5 OC (method El), which may come into contact with steam and hot condensation water and are required to separate from the water quickly. 2 Concept For the purposes of this standard, water separation ability is the ability of lubricating oils or low-flammability fluids to separate from the condensate
6、 formed after steam treatment. 3 Unit The unit in which the water separation ability (settling time) is expressed is the second (s). 4 Principle The sample to be examined is placed in a cylindrical vessel and emulsified by a constant flow of steam, the latter being produced in a steam generator and
7、measured after condensation in a graduated cylinder connected to the cylindrical vessel. The settling time of the aqueous phase (method A) or the separation time of both phases (method 6) is then determi ned. Continued on pages 2 to 6 Page 2 DIN 51 589 Part 1 5 Apparatus The following apparatus shal
8、l be used. a) Emulsifier, equipped with steam generator, as shown in figure 1 ). b) Thermostat, capable of being maintained at (65f5) “C. c) Stopwatch. d) Oven, as specified in DIN 50011 Part 12, rated for temperatures of not less than 110 OC. e) Measuring ring, as shown in ligure 2 (method A). f) M
9、easuring ring, as shown in figure 3 (method E). DIN *) Cf. Explanatory notes. Figure 1. Emulsifier equipped with steam generator (cf. parts list for details) DIN 51 589 Part 1 Page 3 Table 1. Parts list for flgure 1 No. of items 1 - 1 1 1 1 1 - Notes DIN 12264 - A S 19 connector l) (with spherical g
10、round joint) Steam delivery tube made from DIN 12217 - 11 x 1 glass tube, with 2 connectors l) (with spherical ground joint) DIN 12264- BS 19 Emulsifying cylinder with connector 1 and with hook and fused-in DIN 12217 - 11 x 1 glass tube with connector (with spherical ground joint) DIN 12249- E 29/32
11、 DIN 12264 - A S 19 ) Ring mark on emulsifying cylinder at 100 mL Steam delivery tube with ground bevel end. Steam discharge attachment made of 35 X 1.25 tube with connector l) and with steam discharge tube made of DIN 12217 - 11 x 1 glass tube with connector l) (with spherical ground joint) DIN 12
12、249 - B 29/32 DIN 12264- BS 19 Allihn condenser 200 connector l) (with spherical ground joint) With DIN 12264-A S 19 DIN 12680- ME 250 graduated cylinder I I) The specified dimensions are mandatory and new apparatusshall becheckedforcomplianceon supply. 6 Reagents The following reagents shall be use
13、d. a) Toluene. b) Acetone. c) Concentrated sulfuric acid, H2SO4 *). d) Distilled or deionized water (referred to below as water for short). 7 Preparation Cf. figure 1 for Set-up of emulsifying apparatus. Pour 2 1 of water into the steam generator and mark the level reached. After each determination.
14、 top the water up to this level. After a total of ten determinations, empty the steam generator and, after cleaning, refill it with water. Prior to each determination, clean the emulsifying cylinder together with the steam discharge attachment by rinsing with toluene, then with acetone, concentrated
15、 sulfuric acid *) and water. Dry the cleaned apparatus in an oven at (105f2)OC. After cooling to an ambient temperature of 18 to 28 OC, fill the dry emulsifying cylinder with (100f 1) ml of sample at ambient temperature, taking care not to wet the wall of the cylinder above the level of the sample.
16、Heat the cylinder for not less than 15 minutes in a bath at (65f 5) “C. 8 Procedure Heat the water in the steam generator to boiling and pass steam through the delivery tube for two minutes. Remove the emulsifying cylinder from the bath and place it vertically in the apparatus with steam flowing thr
17、ough it. Allow the steam to act for a period of 20 minutes, measured with the stopwatch from the time of placing the emulsifying cylinder in the apparatus. Check the volume of condensate entering the graduated cylinder at five-minute intervals in order to verify whether the steam flow is constant. A
18、fter 20 minutes, thevolume of condensate shall be (205*5) mland the steam generator shall be adjusted to achieve this. Method A Just before the end of steam injection, push the measuring ring shown in figure 2 over the emulsifying cylinder. After 20 minutes, stop the flow of steam by simultaneously
19、opening the straight bore stopcock on the steam generator and switching off the heater. Set the zero mark of the measuring ring to the emulsioniair interface no more than two seconds after stopping the steam injection and start the stopwatch. Observe the drop in the oiliwater phase boundary and read
20、 the time on the stopwatch when it reaches the 55 mm mark. Discontinue the measurement if the observation time exceeds 1800seconds. To facilitate observation of the settling process and to illuminate the apparatus, it is recommended that a lamp be used that is placed to the side in front of or behin
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DIN5158911991DETERMINATIONOFWATERSEPARATIONABILITYOFLUBRICATINGOILSANDLOWFLAMMABILITYFLUIDSAFTERCONTACTWITHSTEAM

链接地址:http://www.mydoc123.com/p-658573.html