《DIN 51375-2-2001 Testing of lubricants - Determination of 1 2-ethanediol content of motor oils - Part 2 Gas chromatography《润滑剂检验 发动机油乙二醇(1 2)含量测定 气相层析法》.pdf》由会员分享,可在线阅读,更多相关《DIN 51375-2-2001 Testing of lubricants - Determination of 1 2-ethanediol content of motor oils - Part 2 Gas chromatography《润滑剂检验 发动机油乙二醇(1 2)含量测定 气相层析法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、ICS 75.100Prfung von Schmierstoffen Bestimmung des Gehaltes an1,2-Ethandiol in Motorenlen Teil 2: GaschromatographischesVerfahrenIn keeping with current practice in standards published by the International Organization for Standardization(ISO), a comma has been used throughout as the decimal marker.
2、Ref. No. DIN 51375-2 : 2001-06English price group 05 Sales No. 010505.03DEUTSCHE NORM June 200151375-2Continued on pages 2 to 5. No part of this translation may be reproduced without the prior permission ofDIN Deutsches Institut fr Normung e.V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has t
3、he exclusive right of sale for German Standards (DIN-Normen).Translation by DIN-Sprachendienst.In case of doubt, the German-language original should be consulted as the authoritative text.Determining the 1,2-ethanediol content ofmotor oils by gas chromatographySupersedes March 1986edition.ForewordTh
4、is standard has been prepared by Technical Committee Prfung von Schmierlen, sonstigen lenund Paraffinen of the Fachausschuss Minerall- und Brennstoffnormung of the NormenausschussMaterialprfung (Materials Testing Standards Committee).AmendmentsThis standard differs from the March 1986 edition as fol
5、lows:a) the specifications for equipment and reagents have been revised;b) details of preparing the standard solution have been changed and the gas chromatographic analysishas been described in greater detail;c) precision data have been updated.Previous editionDIN 51375-2: 1986-03.1 ScopeThe method
6、specified in this standard serves to determine the 1,2-ethanediol content of used and unusedmotor oils, for concentrations of 200 mg/kg or more. 1,2-ethanediol may get into motor oil during production,while in the case of used motor oils, an increased 1,2-ethanediol content may indicate contaminatio
7、n withantifreeze from the cooling water.Additives may be examined by this method, provided that they are diluted with a suitable base oil.2 Normative referencesThis standard incorporates, by dated or undated reference, provisions from other publications. Thesenormative references are cited at the ap
8、propriate places in the text, and the titles of the publications arelisted below. For dated references, subsequent amendments to or revisions of any of these publicationsapply to this standard only when incorporated in it by amendment or revision. For undated references, thelatest edition of the pub
9、lication referred to applies.DIN 1333 Presentation of numerical dataDIN 12691 Class AS fast delivery one-mark bulb pipettes, with a waiting time of 15 seconds, for laboratoryuseDIN 51405 Testing of liquid petroleum products, related liquids and solvents for paints and varnishes bygas chromatography
10、GeneralDIN 51574 Sampling of lubricating oils taken from internal combustion enginesPage 2DIN 51375-2 : 2001-06DIN 51750-1 Sampling of petroleum products GeneralDIN 51750-2 Sampling of liquid petroleum productsDIN EN ISO 4259 Petroleum products Determination and application of precision data in rela
11、tion to methodsof test (ISO 4259 : 1992 + Corr 1 : 1993)3 UnitThe unit in which the content is expressed shall be mg/kg.4 PrincipleA sample of the motor oil under test and an internal standard, 1,3-propanediol (C3H8O2), are applied to aprepacked column to separate the 1,2-ethanediol and the internal
12、 standard from the oil matrix by solid-phaseextraction. The diols are then eluted from the adsorption phase with ethanol and the eluate is analysed by gaschromatography.5 DesignationDesignation of the method of determining the 1,2-ethanediol content of motor oils in accordance with thisstandard (02)
13、 by gas chromatography (GC):Test DIN 51375 02 GC6 Apparatus and reagents6.1 ApparatusThe following equipment shall be used.a) Ultrasonic bath.b) Prepacked diol or silica gel column, for preliminary separation, having a volume of 3 ml or 6 ml/500 mgof solid phase.c) Vacuum unit, with Luer connections
14、.d) Gas chromatograph, with flame ionization detector as in DIN 51405.e) Balance, with 0,1 mg scale intervals.f) One-mark bulb pipette, of capacity 1 ml (e.g. DIN 12691-VPAS 1 pipette).g) Micropipettes, of capacities 1 000 l and 2 000 l.h) Microlitre syringe.i) GC sample containers, of capacities 2,
15、5 ml, 10 ml and 100 ml, with septum closures.j) Disposable medical syringes, of capacity 2 ml.k) Gas chromatography column (e.g. capillary column packed with a polar stationary phase), having aresolution for the individual components of at least R = 5. The column shall be checked at regular interval
16、s,at least twice a year, using a mixture of equal parts of 1,2-ethanediol/1,3-propanediol in ethanol and theresult evaluated as specified in subclause 6.2 of DIN 51405, May 1987 edition.NOTE: In preliminary tests, a capillary column containing polyethylene glycol as stationary phase and havinga diam
17、eter of 0,2 mm, a length of 25 m, and a film thickness of 0,2 m was found satisfactory1).6.2 ReagentsThe following reagents shall be used.a) Cyclohexane1), having a purity of at least 99,8 %.b) Synthesis-grade isobutyl methyl ketone, having a purity greater than 99 %1).c) Analytical grade (absolute)
18、 ethanol.d) Analytical grade 1,2-ethanediol.e) 98 % (m/m) 1,3-propanediol.f) Helium or nitrogen (having a purity of not less than 99,5 % (V/V).g) Hydrogen (having a purity of at least 99,5 % (V/V) and hydrocarbon-free synthetic air, as detector gases.7 SamplingSee DIN 51574, DIN 51750-1 and DIN 5175
19、0-2.1) Information on sources of supply is obtainable from Fachausschuss Minerall- und Brennstoffnormung,Kapstadtring 2, 22297 Hamburg, Germany.8 Procedure8.1 Determining the substance-specific factor8.1.1 Preparation of solutionWeigh, to an accuracy of 0,1 mg, 50 mg to 100 mg each of 1,2-ethanediol
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DIN5137522001TESTINGOFLUBRICANTSDETERMINATIONOF12ETHANEDIOLCONTENTOFMOTOROILSPART2GASCHROMATOGRAPHY 润滑剂

链接地址:http://www.mydoc123.com/p-658454.html