1、September 1985 UDC 621.646-036.742.2:628.1:620.1 DEUTSCHE NORM Test temperature “c High-density polyethylene (HDPE) valves Tapping valves Requirements and test Duration of test service life), in hours Test pressure, in bar, when welded to an HDPE pipe I Part 1 20 1 Armaturen aus Polyethylen hoher Di
2、chte (HDPE); Anforderungen und Prfung von Anbohrarmaturen 2.4 X PN-) Supersedes July 1979 edition. In keeping with current practice in standards published by the International Organization for Standardization (so), a comma has been used throughout as the decimal marker. 1 Field of application This s
3、tandard applies to high-density polyethylene (HDPE) tapping valves. Tapping valves covered by this standard are intended for welding to HDPE pipes as specified in DIN 8075 “1, with dimensions in accordance with DIN 8074 Part 1 or Part 2. The specifications of DIN 16 963 Part 5, July 1977 edition, ta
4、ble 3 are applicable to the permissible working pressures in the case of liquid flow media, and the specifications of D VGW-Arbeitsblatt (Data sheet) G 477 are applicable to the permissible working pressures in the case of combustible gases. 2 Requirements 2.1 Material In the case of potable water p
5、iping systems, only materials shall be used that are not likely to impart either taste, odour or colour to the drinking water, or any substances injurious to health in amounts which could be prejudicial to hygiene. The formation of algae and the growth of bacteria shall not be fostered. The stipulat
6、ions made in the Mitteilungen aus dem Bundesgesundheitsamt (Federal Board of Health Bulletin) on the “Hygienic evaluation of plastic materials within the framework of the Foodstuffs Act“ shall be regarded as authoritative in this respect. 2.1.1 Valves Valves shall be made of highdensity stabilized p
7、oly- ethylene (as a general rule, stabilized with carbon black and suitable antioxidants). Moulding materials of uncontrolled composition shall not be used. The choice of stabilizer and of other auxiliary materials is left to the discretion of the manufacturer of the tapping valve. 2.1.2 Seals The m
8、aterials shall be selected according to the nature of the flow medium. DIN 3535 Part 3 shall be applicable to valves in gas installations. 2.2 Condition on supply Tapping valves shall be free from any shrink holes, inhomogeneities, bubbles and burr which might impair proper functioning. 2.3 Strength
9、 properties Tapping valves shall meet the strength requirements given in table 1 during the long-term hydrostatic pressure test in accordance with subclause 3.2. Table 1. Strength requirements for tapping valves during the long-term hydrostatic pressure test Pressure-bearing valve parts shall neithe
10、r leak nor suffer any fracture during the prescribed duration of the test. Rubber-sealed connections shall be safeguarded against deformations which might result in premature leakage. 2.4 Surface finish Tapping valves shall exhibit a smooth surface appropriate to the manufacturing process at the tim
11、e of the inspec- tion in accordance with subclause 3.3. There shall be no signs of burnt patches due to overheating during manufacture. 2.5 Dimensions DIN 3543 Part4 shall apply to the dimensions of tapping valves. Any dimensions which are not specified in the above-mentioned standard shall be selec
12、ted by the manufacturer in such a way that, apart from the strength requirements laid down in subclause 2.3, the additional stresses likely to occur in practical use can be absorbed by the tapping valves. 3 Testing 3.1 Point in time for performance of tests All tests shall not be performed any earli
13、er than 15 hours after completion of manufacture of the tapping valves. 3.2 Long-term hydrostatic presuie test 3.2.1 Three tapping valves shall be tested for each of the test conditions described in table 1. 3.2.2 The tests shall be carried out on complete tapping valves including their connections,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DIN354411985HIGHDENSITYPOLYETHYLENEHDPEVALVESTAPPINGVALVESREQUIREMENTSANDTEST 高密度 聚乙烯 HDPE 管件第 部分 螺纹

链接地址:http://www.mydoc123.com/p-656350.html