CLC TS 50544-2010 Low voltage d c surge protective device for traction systems - Selection and application rules for surge arresters《牵引系统用低电压直流浪涌保护装置 避雷器的选择和应用规则》.pdf
《CLC TS 50544-2010 Low voltage d c surge protective device for traction systems - Selection and application rules for surge arresters《牵引系统用低电压直流浪涌保护装置 避雷器的选择和应用规则》.pdf》由会员分享,可在线阅读,更多相关《CLC TS 50544-2010 Low voltage d c surge protective device for traction systems - Selection and application rules for surge arresters《牵引系统用低电压直流浪涌保护装置 避雷器的选择和应用规则》.pdf(30页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationLow voltage d.c. surge protectivedevice for traction systems Selection and application rules forsurge arrestersDD CLC/TS 50544:2010National forewordThis Draft for Development is
2、the UK implementation of CLC/TS 50544:2010.The UK participation in its preparation was entrusted by Technical CommitteePEL/37, Surge Arresters - High Voltage, to Subcommittee PEL/37/1, SurgeArresters - Low Voltage.A list of organizations represented on this committee can be obtained onrequest to its
3、 secretary.This publication does not purport to include all the necessary provisions of acontract. Users are responsible for its correct application. BSI 2010ISBN 978 0 580 69171 3ICS 29.120.50; 29.280Compliance with a British Standard cannot confer immunity fromlegal obligations.This Draft for Deve
4、lopment was published under the authority of theStandards Policy and Strategy Committee on 30 April 2010.Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDDD CLC/TS 50544:2010TECHNICAL SPECIFICATION CLC/TS 50544 SPCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION February 201
5、0 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: Avenue Marnix 17, B - 1000 Brussels 2010 CENELEC - All rights of exploitation in any form and by any means reserved
6、worldwide for CENELEC members. Ref. No. CLC/TS 50544:2010 E ICS 29.120.50; 29.280 English version Low voltage d.c. surge protective device for traction systems - Selection and application rules for surge arresters Parafoudres basse tension courant continu pour traction - Principes de choix et dappli
7、cation pour les parafoudres berspannungsschutzgerte fr Niederspannungs-Gleichstrom-Bahnsysteme - Auswahl und Anwendungsregeln fr berspannungsableiter This Technical Specification was approved by CENELEC on 2009-12-25. CENELEC members are required to announce the existence of this TS in the same way
8、as for an EN and to make the TS available promptly at national level in an appropriate form. It is permissible to keep conflicting national standards in force. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Es
9、tonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. DD CLC/TS 50544:2010CLC/TS 50544:2010 2 Foreword This Technical
10、Specification was prepared by the Technical Committee CENELEC TC 37A, Low voltage surge protective devices. It also concerns the expertise of SC 9XC, Electric supply and earthing systems for public transport equipment and ancillary apparatus (Fixed installations), of Technical Committee CENELEC TC 9
11、X, Electrical and electronic applications for railways. The broad subject of overvoltage protection in d.c. traction systems need to address the approaches, requirements and definitions of several disciplines and TCs. Concerned European Standards are referenced for generic definitions. This Technica
12、l Specification reflects the common practise of overvoltage protection in the d.c. traction community, as far as protection of equipment in the primary power supply is concerned (e.g. feeders, overhead contact lines, return circuits, power side of rolling stock). Therefore, definitions and approache
13、s in this Technical Specification, covering a specific application in line with EN 50526-1, are different for some aspects from the definitions and approaches in the EN 61643 series. The text of the draft was circulated for voting in accordance with the Internal Regulations, Part 2, Subclause 11.3.3
14、.3. and was approved by CENELEC as CLC/TS 50544 on 2009-12-25. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights. The following date is prop
15、osed: latest date by which the existence of the CLC/TS has to be announced at national level (doa) 2010-06-25 This Technical Specification will be withdrawn once the SC 9XC document 1)on the same subject is published. _ 1)Under development at the time of issue. DD CLC/TS 50544:2010 3 CLC/TS 50544:20
16、10 Contents 1 Scope . 5 2 Normative references . 5 3 Terms and definitions 5 3.1 System voltages . 5 3.2 Arrester . 7 4 Systems and equipment to be protected . 9 4.1 General . 9 4.2 Substations . 9 4.3 Overhead contact line system 10 4.4 Return circuit 11 4.5 Rolling stock .12 5 Supply voltages 13 6
17、 Overvoltages .13 6.1 Lightning overvoltages 13 6.2 Switching overvoltages .14 7 Function and characteristics of MO surge arresters 14 7.1 Basic function .14 7.2 Characteristics 15 7.3 Classification 16 8 Insulation co-ordination and application of MO surge arresters .17 8.1 General .17 8.2 Principl
18、es of insulation co-ordination 17 8.3 Protective distance .19 8.4 Protection level .22 8.5 Surge arresters connected in parallel .22 9 Selection of MO surge arresters .23 9.1 Continuous operating voltage Uc23 9.2 Arrester class 23 9.3 Mechanical considerations .23 Annex A (informative) Supply voltag
19、es 24 Bibliography 25 Figures Figure 1 Protective circuit in a substation (principle arrangement) .10 Figure 2 Principle of a protective circuit of a line (outdoor system) 11 Figure 3 Installation of surge arresters on the overhead contact line and the running rails .12 Figure 4 Surge arrester arran
20、gement on a vehicle .13 Figure 5 Current-voltage characteristic of an MO surge arrester 15 Figure 6 Requirements and design of surge arresters 17 Figure 7 Assumption for the calculation of the voltage at the open end of a line and for the determination of the protective distance L .20 Figure 8 Volta
21、ge funnel and illustration of protective distance 21 DD CLC/TS 50544:2010CLC/TS 50544:2010 4 Tables Table 1 Arrester classification and related parameters. 16 Table 2 Insulation levels 18 Table A.1 Supply voltages .24 DD CLC/TS 50544:2010 5 CLC/TS 50544:2010 1 Scope This Technical Specification appl
22、ies to non linear metal-oxide resistor type surge arresters (MO surge arresters) without spark gaps designed to limit voltage surges on d.c. traction systems with nominal voltage up to 1 500 V. This Technical Specification applies to protection of equipment. Same principles for selection and applica
23、tion apply for MO surge arresters on d.c. traction systems with nominal voltage 3 000 V. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition
24、of the referenced document (including any amendments) applies. EN 50122-2 Railway applications Fixed installations Part 2: Protective provisions against the effects of stray currents caused by d.c. traction systems EN 50124-1 Railway applications Insulation coordination Part 1: Basic requirements Cl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CLCTS505442010LOWVOLTAGEDCSURGEPROTECTIVEDEVICEFORTRACTIONSYSTEMSSELECTIONANDAPPLICATIONRULESFORSURGEARRESTERS

链接地址:http://www.mydoc123.com/p-629603.html