CLC TR 50600-99-2-2018 Information technology - Data centre facilities and infrastructures - Part 99-2 Recommended practices for environmental sustainability.pdf
《CLC TR 50600-99-2-2018 Information technology - Data centre facilities and infrastructures - Part 99-2 Recommended practices for environmental sustainability.pdf》由会员分享,可在线阅读,更多相关《CLC TR 50600-99-2-2018 Information technology - Data centre facilities and infrastructures - Part 99-2 Recommended practices for environmental sustainability.pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06Information technology - Data centre facilities and infrastructuresPart 99-2: Recommended practices for environmental sustainabilityPD CLC/TR 50600-99-2:2018TECHNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CLC/TR
2、50600-99-2 August 2018 ICS 35.020; 35.110; 35.160 English Version Information technology - Data centre facilities and infrastructures - Part 99-2: Recommended practices for environmental sustainability Technologies de linformation - Installations et infrastructures des centres de traitement de donne
3、s - Partie 99-2 : Pratiques recommandes en faveur de la durabilit environnementale Informationstechnik - Einrichtungen und Infrastrukturen von Rechenzentren - Teil 99-2: Empfohlene Praktiken fr umweltbezogene Nachhaltigkeit This Technical Report was approved by CENELEC on 2018-07-09. CENELEC members
4、 are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway
5、, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre:
6、Rue de la Science 23, B-1040 Brussels 2018 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. CLC/TR 50600-99-2:2018 E National forewordThis Published Document is the UK implementation of CLC/TR 50600992:2018.The UK participation in its p
7、reparation was entrusted to Technical Committee TCT/7, Telecommunications Installation requirements.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are res
8、ponsible for its correct application. The British Standards Institution 2018 Published by BSI Standards Limited 2018ISBN 978 0 539 00018 4ICS 35.020; 35.160; 35.110Compliance with a British Standard cannot confer immunity from legal obligations.This Published Document was published under the authori
9、ty of the Standards Policy and Strategy Committee on 31 August 2018.Amendments/corrigenda issued since publicationDate Text affectedPUBLISHED DOCUMENTPD CLC/TR 50600992:2018TECHNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CLC/TR 50600-99-2 August 2018 ICS 35.020; 35.110; 35.160 English Version
10、 Information technology - Data centre facilities and infrastructures - Part 99-2: Recommended practices for environmental sustainability Technologies de linformation - Installations et infrastructures des centres de traitement de donnes - Partie 99-2 : Pratiques recommandes en faveur de la durabilit
11、 environnementale Informationstechnik - Einrichtungen und Infrastrukturen von Rechenzentren - Teil 99-2: Empfohlene Praktiken fr umweltbezogene Nachhaltigkeit This Technical Report was approved by CENELEC on 2018-07-09. CENELEC members are the national electrotechnical committees of Austria, Belgium
12、, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, S
13、weden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels 2018 CENELEC All rights of
14、exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. CLC/TR 50600-99-2:2018 E PD CLC/TR 50600992:2018CLC/TR 50600-99-2:2018 (E) 2 Contents Page European foreword .3 Introduction .4 1 Scope .7 2 Normative references .7 3 Terms, definitions and abbreviations 7 3.1
15、 Terms and definitions .7 3.2 Abbreviations 8 4 Environmental sustainability .9 4.1 General .9 4.2 Life cycle assessment 9 4.3 Data centre boundaries 10 5 Recommended practices for processes .11 6 Recommended practices for source energy mix 13 6.1 General .13 6.2 New facilities .14 6.3 Existing faci
16、lities .15 7 Recommended practices for embodied impact of ICT equipment .16 8 Recommended practices for embodied impact of mechanical and electrical systems 19 8.1 New facilities .19 8.2 Existing facilities .20 Annex A (informative) Examples of simplified LCA metrics .21 A.1 Direct Material Input of
17、 a Data Centre (DC-DMI) .21 A.2 Data Centre Cumulative Energy Demand (DC-CED) .21 A.3 Data Centre Carbon Footprint (DC-CF) .22 A.4 Support, data and further information .22 Bibliography 23 PD CLC/TR 50600992:2018CLC/TR 50600-99-2:2018 (E) 3 European foreword This document (CLC/TR 50600-99-2:2018) wa
18、s prepared by the Technical Committee CENELEC TC 215, Electrotechnical aspects of telecommunication equipment. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC shall not be held responsible for identifying any or all such p
19、atent rights. This document has been prepared under a mandate given to CENELEC by the European Commission and the European Free Trade Association. Regarding the structure of the EN 50600 series, see the Introduction. PD CLC/TR 50600992:2018CLC/TR 50600-99-2:2018 (E) 4 Introduction The unrestricted a
20、ccess to internet-based information demanded by the information society has led to an exponential growth of both internet traffic and the volume of stored/retrieved data. Data centres are housing and supporting the information technology and network telecommunications equipment for data processing,
21、data storage and data transport. They are required both by network operators (delivering those services to customer premises) and by enterprises within those customer premises. Data centres need to provide modular, scalable and flexible facilities and infrastructures to easily accommodate the rapidl
22、y changing requirements of the market. In addition, energy consumption of data centres has become critical both from an environmental point of view (reduction of carbon footprint) and with respect to economic considerations (cost of energy) for the data centre operator. The implementation of data ce
23、ntres varies in terms of: a) purpose (enterprise, co-location, co-hosting, or network operator facilities); b) security level; c) physical size; d) accommodation (mobile, temporary and permanent constructions). The needs of data centres also vary in terms of availability of service, the provision of
24、 security and the objectives for energy efficiency. These needs and objectives influence the design of data centres in terms of building construction, power distribution, environmental control and physical security. Effective management and operational information is required to monitor achievement
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CLCTR506009922018INFORMATIONTECHNOLOGYDATACENTREFACILITIESANDINFRASTRUCTURESPART992RECOMMENDEDPRACTICESFORENVIRONMENTALSUSTAINABILITYPDF

链接地址:http://www.mydoc123.com/p-629529.html