《CLC TR 50579-2012 Electricity metering equipment (a c ) - Severity levels immunity requirements and test methods for conducted disturbances in the frequency range 2 kHz - 150 kHz.pdf》由会员分享,可在线阅读,更多相关《CLC TR 50579-2012 Electricity metering equipment (a c ) - Severity levels immunity requirements and test methods for conducted disturbances in the frequency range 2 kHz - 150 kHz.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationElectricity metering equipment (a.c.) Severity levels, immunity requirements and test methods for conducted disturbances in the frequencyrange 2 kHz 150 kHzPD CLC/TR 50579:2012Na
2、tional forewordThis Published Document is the UK implementation of CLC/TR 50579:2012. The UK participation in its preparation was entrusted to Technical CommitteePEL/13, Electricity Meters.A list of organizations represented on this committee can be obtained on request to its secretary.This publicat
3、ion does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2012Published by BSI Standards Limited 2012 ISBN 978 0 580 78265 7 ICS 91.140.50Compliance with a British Standard cannot confer immunity f
4、rom legal obligations.This Published Document was published under the authority of the Standards Policy and Strategy Committee on 31 July 2012.Amendments issued since publicationDate Text affectedPUBLISHED DOCUMENTPD CLC/TR 50579:2012TECHNICAL REPORT CLC/TR 50579 RAPPORT TECHNIQUE TECHNISCHER BERICH
5、T June 2012 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2012 CENELEC - All rights of exploitation in any form and by any means r
6、eserved worldwide for CENELEC members. Ref. No. CLC/TR 50579:2012 E ICS 91.140.50 English version Electricity metering equipment (a.c.) - Severity levels, immunity requirements and test methods for conducted disturbances in the frequency range 2 kHz - 150 kHz Equipement de comptage dlectricit (c.a.)
7、 Niveaux de svrit, prescriptions dimmunit et mthodes dessai pour les perturbations conduites dans le domaine de frquence de 2 kHz 150 kHz Wechselstrom-Elektrizittszhler -Prfschrfe, Strfestigkeit und Prfverfahren fr leitungsgefhrte Strgren im Frequenzbereich von 2 kHz bis 150 kHz This Technical Repor
8、t was approved by CENELEC on 2012-06-04. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Ne
9、therlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. PD CLC/TR 50579:2012CLC/TR 50579:2012 - 2 - Contents Page Foreword . - 3 -Introduction - 4 -1 Scope - 5 -2 Normative references - 5 -3 Terms and definitions - 5 -4 General . -
10、 6 -5 Test equipment - 7 -5.1 Test generator for the disturbing current . - 7 -5.1.1 General - 7 -5.1.2 Example of a test generator for the disturbing current . - 7 -5.2 Generator for 50 Hz current and voltage . - 8 -5.2.1 General - 8 -5.2.2 Example for a testing circuit . - 9 -6 Test sequence . - 9
11、 -7 Performance criteria Performance criteria for electricity meter as described in EN 50470-1 and EN 50470-3 . - 10 -Annex A (informative) Example for a realised test set-up Setup schematic - 11 -Bibliography . - 12 -PD CLC/TR 50579:2012- 3 - CLC/TR 50579:2012 Foreword This document (CLC/TR 50579:2
12、012) has been prepared by CLC/TC 13 “Equipment for electrical energy measurement and load control“. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such p
13、atent rights. PD CLC/TR 50579:2012CLC/TR 50579:2012 - 4 - Introduction This Technical Report specifies immunity levels and standard testing procedure for the immunity against symmetric currents in the frequency range from 2 kHz to 150 kHz as an extension of the harmonised standards EN 50470-1 and EN
14、 50470-3 until the basic standards IEC 61000-x-x are in force. This Technical Report was requested by various approval bodies and utilities as a temporary solution, since accuracy problems with electricity meters were observed in presence of disturbing currents in the frequency range from 2 kHz to 1
15、50 kHz. Up to date no standards are available for this frequency range. The testing against symmetrical currents is not yet a part of the actual basic standards or product standards in EMC. However for some electricity meters an influence of symmetric currents has been shown in various investigation
16、s. The source of these currents in a frequency range from 2 kHz to 150 kHz can be a photovoltaic inverter or other switched mode power supplies. PD CLC/TR 50579:2012- 5 - CLC/TR 50579:2012 1 Scope This European Technical Report applies to newly manufactured static watt-hour meters intended for resid
17、ential, commercial and light industrial use, of class indexes A, B and C, for the measurement of alternating current electrical active energy in 50 Hz networks. It specifies particular requirements and immunity test for direct connected and transformer connected electricity meters as an extension fo
18、r EN 50470-1 and EN 50470-3. The tests are designed to achieve immunity against disturbing currents of up to 2 A (2 kHz-30 kHz) and up to 1 A (30 KHz-150 kHz) for direct connected meters and 2 % Imax (2 kHz-30 kHz) and 1 % Imax (30 KHz-150 kHz) for transformer connected meters. It applies to static
19、watt-hour meters for indoor and outdoor application, consisting of a measuring element and register(s) enclosed together in a meter case. If the meter has (a) measuring element(s) for more than one type of energy (multi-energy meters), or when other functional elements, like maximum demand indicator
20、s, electronic tariff registers, time switches, ripple control receivers, data communication interfaces etc. are enclosed in the meter case (multi-function meters) then this Technical Report applies only for the active energy metering part. This Technical Report distinguishes between: meters of class
21、 indexes A, B and C; direct connected and transformer operated meters; It does not apply to: watt-hour meters where the voltage across the connection terminals exceeds 600 V (line-to-line voltage for meters for polyphase systems); portable meters; reference meters. 2 Normative references The followi
22、ng documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 50470-1, Electr
23、icity metering equipment (a.c.) Part 1: General requirements, tests and test conditions Metering equipment (class indexes A, B and C) EN 50470-3:2006, Electricity metering equipment (a.c.) Part 3: Particular requirements Static meters for active energy (class indexes A, B and C) 3 Terms and definiti
24、ons For the purposes of this document, the following terms and definitions apply. 3.1 equipment under test (EUT) electricity meter or other instrumentation for the measurement of energy which is tested against the disturbing current described in this Technical Report PD CLC/TR 50579:2012CLC/TR 50579
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CLCTR505792012ELECTRICITYMETERINGEQUIPMENTACSEVERITYLEVELSIMMUNITYREQUIREMENTSANDTESTMETHODSFORCONDUCTEDDISTURBANCESINTHEFREQUENCYRANGE2KHZ150KHZPDF

链接地址:http://www.mydoc123.com/p-629526.html