CLC TR 50485-2010 Electromagnetic compatibility - Emission measurements in fully anechoic chambers《电磁兼容性 全电波暗室中电磁干扰度测量》.pdf
《CLC TR 50485-2010 Electromagnetic compatibility - Emission measurements in fully anechoic chambers《电磁兼容性 全电波暗室中电磁干扰度测量》.pdf》由会员分享,可在线阅读,更多相关《CLC TR 50485-2010 Electromagnetic compatibility - Emission measurements in fully anechoic chambers《电磁兼容性 全电波暗室中电磁干扰度测量》.pdf(48页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationElectromagnetic compatibility Emission measurements in fullyanechoic chambersPD CLC/TR 50485:2010National forewordThis Published Document is the UK implementation of CLC/TR 50485
2、:2010. Itsupersedes PD CR R210-010:2002 which is withdrawn.The UK participation in its preparation was entrusted by Technical CommitteeGEL/210, EMC - Policy committee, to Subcommittee GEL/210/12, EMC basic,generic and low frequency phenomena Standardization.A list of organizations represented on thi
3、s committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions of acontract. Users are responsible for its correct application. BSI 2010ISBN 978 0 580 64296 8ICS 33.100.10Compliance with a British Standard cannot confer immunity froml
4、egal obligations.This Published Document was published under the authority of theStandards Policy and Strategy Committee on 30 June 2010.Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDPD CLC/TR 50485:2010TECHNICAL REPORT CLC/TR 50485 RAPPORT TECHNIQUE TECHNISCHER BERIC
5、HT March 2010 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: Avenue Marnix 17, B - 1000 Brussels 2010 CENELEC - All rights of exploitation in any form and by any mea
6、ns reserved worldwide for CENELEC members. Ref. No. CLC/TR 50485:2010 E ICS 33.100.10 Supersedes R210-010:2002English version Electromagnetic compatibility - Emission measurements in fully anechoic chambers Compatibilit lectromagntique - Emission en chambres anchoques entiers Elektromagnetische Vert
7、rglichkeit - Straussendung in Absorberrumen This Technical Report was approved by CENELEC on 2009-12-17. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Icela
8、nd, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. PD CLC/TR 50485:2010CLC/TR 50485:2010 2 Foreword This Technical Report was prepared by the Technical Committee CENELEC
9、TC 210, Electromagnetic Compatibility (EMC). This document supersedes R210-010:2002. In order not to loose the information provided in R210-010:2002, CENELEC TC 210 decided to transfer the content of that document unchanged into a Technical Report. It should be noted that CISPR incorporated a major
10、part of the document R210-010:2002 into the CISPR 16 series and the references to standards were not updated. The document still provides a comprehensive overview and describes some fundamental items of interest for the appropriate use of fully anechoic chambers. The main reason for keeping the docu
11、ment in the public domain in this new form is that it contains background information that has not been included in EN 55016-1-4. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for id
12、entifying any or all such patent rights. PD CLC/TR 50485:2010 3 CLC/TR 50485:2010 Contents 1 Scope 5 2 References .5 3 Definitions and abbreviations 6 3.1 Definitions .6 3.2 Abbreviations 7 4 Test and measurement equipment 7 4.1 Fully Anechoic Rooms (FARs) 7 4.2 Antenna .7 5 Anechoic room performanc
13、e .8 5.1 Theoretical normalised site attenuation 8 5.2 Room validation procedure 10 5.3 Anechoic room requirements . 13 6 Emission measurement . 13 6.1 Test set up . 13 6.2 EUT position . 15 6.3 Cable layout and termination . 16 7 Test procedure . 17 8 Test plan 17 9 Test report . 18 Annex A (inform
14、ative) Determining the Site Reference . 19 Annex B (informative) Limit values 21 Annex C (informative) Comparison of measurement uncertainties for 3 m OATS and 3 m FAR . 27 C.1 Introduction 27 C.2 Uncertainty budgets for 3 m OATS and 3 m FAR 28 C.3 Comments on uncertainty budgets 30 Annex D (informa
15、tive) Derivation of free space NSA formula . 32 D.1 Theoretical free space Normalised Site Attenuation 32 D.2 NSA formula for near-field separations 35 Annex E (informative) Corrections of field strength for test distance 36 E.1 Introduction 36 E.2 Field strength correction factor for LPDAs . 37 Ann
16、ex F (informative) NSA measurements with biconical antennas . 38 F.1 Background 38 F.2 ANSI method 39 F.3 Conclusion . 39 Annex G (informative) Measurement of Balun imbalance . 40 Annex H (informative) FAR project . 41 H.1 Description of the FAR project . 41 H.2 Rationale of the FAR project 41 Bibli
17、ography . 43 PD CLC/TR 50485:2010CLC/TR 50485:2010 4 Figures Figure 1 Theoretical NSA 9 Figure 2 Measurement points in room validation procedure 11 Figure 3 Typical test set-up in FAR, where a, b, c and e depend on the room performance 14 Figure 4 Typical test set-up for table top equipment within t
18、he test volume of a FAR . 15 Figure 5 Typical test set-up for floor standing equipment within the test volume of a FAR . 16 Figure A.1 Free space site reference measurement set up . 20 Figure B.1 Differences in emission measurement results between OATS and FAR . 22 Figure B.2 Geometrical optics mode
19、l for OATS measurements 23 Figure B.3 Field attenuation between two half-wave dipoles above ground plane with fixed transmit antenna height and variable receive antenna height . 23 Figure B.4 Equivalent circuit diagram of a typical Equipment Under Test (EUT) 24 Figure B.5 Differences in the received
20、 field strength of an electrically short straight wire on an ideal OATS (1 m 4 m scan of the receive antenna), and in a FAR (EOATS EFAR) 25 Figure B.6 Differences in the received field strength of an electrically short straight wire on an ideal OATS (1 m 4 m scan of the receive antenna), and in a FA
21、R (EOATS EFAR) 26 Figure F.1 NSA values for free space, calculated for a small and a large biconical antenna separated by 3 m 38 Tables Table 1 Frequency ranges and step sizes . 11 Table 2 Relation between maximum diameter of EUT and test distance 13 Table B.1 Preferred limits . 21 Table C.1 Uncerta
22、inty budget for emission measurements on 3 m open area test site 28 Table C.2 Uncertainty budget for emission measurements in 3 m FAR 29 PD CLC/TR 50485:2010 5 CLC/TR 50485:2010 1 Scope This Technical Report applies to emission measurements of radiated electromagnetic fields in Fully Anechoic Rooms
23、(FAR) in the frequency range from 30 MHz to 18 GHz. This Technical Report covers the frequency range from 30 MHz 1 000 MHz. The frequency range above 1 GHz is under consideration, due to the absence of practical experience. This Technical Report describes the validation procedure for the Fully Anech
24、oic Room for radiated emission tests and the procedures to carry out the tests (e.g. test set up, EUT position, cable layout and termination, test procedures). Recommendations for the relation between FAR emission limits and common Open Area Test Site (OATS) emission limits given in standards such a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CLCTR504852010ELECTROMAGNETICCOMPATIBILITYEMISSIONMEASUREMENTSINFULLYANECHOICCHAMBERS 电磁 兼容性 电波 暗室 干扰

链接地址:http://www.mydoc123.com/p-629510.html