CLC TR 50456-2008 Guidelines to achieving compliance with EC directives for alarm systems《报警系统 电子报警系统符合EC指令指南》.pdf
《CLC TR 50456-2008 Guidelines to achieving compliance with EC directives for alarm systems《报警系统 电子报警系统符合EC指令指南》.pdf》由会员分享,可在线阅读,更多相关《CLC TR 50456-2008 Guidelines to achieving compliance with EC directives for alarm systems《报警系统 电子报警系统符合EC指令指南》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、PUBLISHED DOCUMENTPD CLC/TR 50456:2008Alarm systems Guidelines to achieving compliance with EC directives for equipment of alarm systems ICS 13.320g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g
2、3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58PD CLC/TR 50456:2008This Published Document was published under the authority of the Standards Policy and Strategy Committee on 31 March 2008 BSI 2008ISBN 978 0 580 57665 2National forewordThis Published Document is the UK implementation of CLC/TR 50456
3、:2008. It supersedes PD CLC/TR 50456:2005 which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee GW/1, Electronic security systems.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purp
4、ort to include all the necessary provisions of a contract. Users are responsible for its correct application.Amendments/corrigenda issued since publicationDate CommentsTECHNICAL REPORT CLC/TR 50456 RAPPORT TECHNIQUE TECHNISCHER BERICHT January 2008 CENELEC European Committee for Electrotechnical Sta
5、ndardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. CLC/TR 5045
6、6:2008 E ICS 13.320 Supersedes CLC/TR 50456:2005English version Alarm systems - Guidelines to achieving compliance with EC directives for equipment of alarm systems Systmes dalarme - Guide pour obtenir satisfaction aux directives CE pour les matriels de systmes dalarme Alarmanlagen - Leitfaden fr Ei
7、nrichtungen von Alarmanlagen zur Erreichung der bereinstimmung mit EG-Richtlinien This Technical Report was approved by CENELEC on 2007-07-27. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Ge
8、rmany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. - 2 - Foreword This Technical Report was prepared by the Technical Committee CENELEC TC 79
9、, Alarm systems. The text of the draft was submitted to the vote in accordance with the Internal Regulations, Part 2, Subclause 11.4.3.3 (simple majority) and was approved by CENELEC as CLC/TR 50456 on 2007-07-27. This Technical Report supersedes CLC/TR 50456:2005. _ CLC/TR 50456:2008- 3 -Contents I
10、ntroduction. 4 1 Scope 5 2 Definitions and abbreviations. 5 2.1 Definitions. 5 2.2 Abbreviations 6 3 List of EC directives directly covering equipment used in alarm systems 7 4 List of standards to be referred to for presumption of conformity to EC directives mentioned in Clause 3.8 Tables Table 1 E
11、C directives directly covering equipment used in alarm systems. 7 Table 2 R - among the applicable directives the second step consisted in the identification of those Essential Requirements (ERs) which apply to equipment used in alarm systems; - the final question was: Do harmonized standards exist,
12、 listed in the Official Journal of the European Union, which may be used as reference to provide presumption of compliance with the identified Essential Requirements applicable to equipment used in alarm systems. If the answer is “yes” the manufacturer is entrusted to refer to these harmonized stand
13、ards. The equipment will be tested accordingly. A test report will give the results after testing. This route will show presumption of conformity. If the answer is “no” the way to show compliance of conformity is more complicated. In the absence of a harmonized standard one has to study the directiv
14、es concerned carefully in order to find out how compliance with Essential Requirements can be shown. But in both cases the equipment will bear the CE marking, which would indicate that the equipment complies with all Essential Requirements of any EC directive which is applicable. In certain cases te
15、sting and certification by an independent third party might be requested. This CE marking can be considered as a passport allowing the free circulation of products in the EU. However, CLC/TC 79 wants to draw the attention of all interested parties and in particular of the user to the fact that CE ma
16、rking does not necessarily ensure for example: sufficient reliability of the products, sufficient functionality concerning the intended use of the products and compatibility with other products or systems. Therefore the existence of harmonized standards seems to be the most efficient way to show pre
17、sumption of compliance. This document is an attempt to answer these questions. It is considered as a guideline of CLC/TC 79 regarding the references which shall be used during the standardization process. CLC/TC 79 wished this document to be published as a CENELEC Technical Report in order to guide
18、all interested bodies, companies and individuals interested in alarm systems on how to use standards for the implementation of the EC directives. CLC/TR 50456:2008- 5 -1 Scope This Technical Report gives guidance on the use of standards for alarm systems in the frame of the implementation of the EC
19、directives. Its purpose is: to find, among all EC directives, those directives which are directly covering equipment used in alarm systems; to identify the Essential Requirements (ERs) of the above EC directives which have to be taken into account during the standardization process and which should
20、be known by bodies interested with equipment used in alarm systems; to register the standards that CLC/TC 79 recommends to use for showing presumption of conformity according to the EC directives and the ERs previously identified. This Technical Report mainly covers equipment used in the following f
21、ields of activities: access control, alarm transmission, CCTV, fire detection and fire alarm, intrusion and hold-up, social alarm. 2 Definitions and abbreviations 2.1 Definitions 2.1.1 access control system system which comprises all the constructional and organisational measures as well as those pe
22、rtaining to the apparatus which are required for controlling access 2.1.2 alarm system an electrical installation which responds to the manual or automatic detection of a presence of a hazard 2.1.3 alarm transmission system a system which is used to transfer information between one or more alarm sys
23、tems and one or more alarm centres 2.1.4 CCTV surveillance system a CCTV surveillance system consists of camera equipment, monitoring and associated equipment for transmission and controlling purposes which may be necessary for the surveillance of a defined security zone 2.1.5 fire detection and fir
24、e alarm system FDAS group of components including a CIE which, when arranged in (a) specified configuration(s), is capable of detecting and indicating a fire, and giving signals for appropriate action 2.1.6 hold-up alarm system alarm system providing the means for a user to deliberately generate a h
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CLCTR504562008GUIDELINESTOACHIEVINGCOMPLIANCEWITHECDIRECTIVESFORALARMSYSTEMS 报警 系统 电子 符合 EC 指令 指南 PDF

链接地址:http://www.mydoc123.com/p-629502.html