CSA T568 2-5-2005 Commercial building telecommunications cabling standard Part 2 Balanced twisted-pair cabling components Addendum 5 Corrections to TIA EIA-568-B 2 (First Editio.pdf
《CSA T568 2-5-2005 Commercial building telecommunications cabling standard Part 2 Balanced twisted-pair cabling components Addendum 5 Corrections to TIA EIA-568-B 2 (First Editio.pdf》由会员分享,可在线阅读,更多相关《CSA T568 2-5-2005 Commercial building telecommunications cabling standard Part 2 Balanced twisted-pair cabling components Addendum 5 Corrections to TIA EIA-568-B 2 (First Editio.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、 T568.2-5-05(ANSI/TIA-568-B.2-5-2003)Commercial building telecommunications cabling standard Part 2: Balanced twisted-pair cabling components Addendum 5 Corrections to TIA/EIA-568-B.2CSA Standard T568.2-5-05 (ANSI/TIA-568-B.2-5-2003) Commercial building telecommunications cabling standard Part 2: Ba
2、lanced twisted-pair cabling components Addendum 5 Corrections to TIA/EIA-568-B.2 Published in May 2005 by Canadian Standards Association A not-for-profit private sector organization 5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5N61-800-463-6727 416-747-4044 Visit our Online Store a
3、t www.ShopCSA.ca Commercial building telecommunications cabling standard Part 2: Balanced twisted-pair cabling components T568.2-5-05 Addendum 5 Corrections to TIA/EIA-568-B.2 CSA/2 Canadian Standards Association May 2005 T568.2-5-05 Commercial building telecommunications cabling standard Part 2: Ba
4、lanced twisted-pair cabling components Addendum 5 Corrections to TIA/EIA-568-B.2 CSA Preface This is the first edition of CSA T568.2-5, Commercial building telecommunications cabling standard Part 2: Balanced twisted-pair cabling components Addendum 5 Corrections to TIA/EIA-568-B.2. This Standard is
5、 an adoption of the identically titled ANSI/TIA (American National Standards Institute/ Telecommunications Industry Association) Standard 568-B.2-5-2003 and is the product of the Telecommunications Industry Association TR-42 Technical Committee, which included a number of Canadian members in order t
6、o ensure that Canadian perspectives and requirements were addressed. It is written in SI (metric) units with yard/pound (imperial) units in parentheses. This Standard has been adopted with no technical deviations. Where code requirements or regulations necessitate changes from US to Canadian referen
7、ces, they should be made by the user, as follows: (a) Throughout this Standard, replace the term “American” with “Canadian”, as applicable. (b) Throughout this Standard, replace the term “state” with “provincial or territorial”, as applicable. (c) Throughout this Standard, replace “NEC” with “CE Cod
8、e, Part I” (Canadian Electrical Code), as applicable. In addition, (i) where reference is made to “conduit”, replace it with “conduit/EMT” (electrical metallic tubing) because, in accordance with the Canadian Electrical Code, Part I, EMT is not considered a type of conduit; and (ii) the definitions
9、of the following terms are to be taken from the Canadian Electrical Code, Part I: “Bonding”, “Ground”, and “Raceway”. (d) Throughout this Standard, where reference is made to “FCC”, replace it with “CRTC” (Canadian Radio-television and Telecommunications Commission), or “Industry Canada”, as applica
10、ble. (e) The following Standard, published by the Canadian Standards Association, is an adoption of a TIA/EIA Standard. The requirements of this CSA Standard take precedence over the TIA/EIA Standard on which it is based; any reference in CSA T568.2-5 to the TIA/EIA Standard is to be replaced by a r
11、eference to the equivalent Canadian Standard: T568.2-05, Commercial building telecommunications cabling standard Part 2: Balanced twisted-pair cabling components. (f) Throughout this Standard, replace the term “Listed” with “Approved as applied to electrical equipment”. This Standard was reviewed fo
12、r Canadian adoption by the CSA Technical Committee on Telecommunications Wiring Systems, under the jurisdiction of the Strategic Steering Committee on Information and Communications Technology, and has been formally approved by the Technical Committee. A list of the members of the Technical Committe
13、e is available upon request. Commercial building telecommunications cabling standard Part 2: Balanced twisted-pair cabling components T568.2-5-05 Addendum 5 Corrections to TIA/EIA-568-B.2 May 2005 Canadian Standards Association CSA/3 May 2005 Canadian Standards Association 2005 All rights reserved.
14、No part of this publication may be reproduced in any form whatsoever without the prior permission of the publisher. TIA material is reprinted with permission. Inquiries regarding this CSA Standard should be addressed to Canadian Standards Association 5060 Spectrum Way, Suite 100, Mississauga, Ontari
15、o, Canada L4W 5N6 1-800-463-6727 416-747-4044 www.csa.ca TIA STANDARD ANSI/TIA-568-B.2-5-2003 Approved: January 16, 2003 Commercial Building Telecommunications Cabling Standard Part 2: Balanced Twisted-Pair Cabling Components Addendum 5 Corrections to TIA/EIA-568-B.2 TIA-568-B.2-5 (Addendum No. 5 to
16、 TIA/EIA-568-B.2) January 2003 TELECOMMUNICATIONS INDUSTRY ASSOCIATION Representing the telecommunications industry in association with the Electronic Industries Alliance NOTICE TIA Engineering Standards and Publications are designed to serve the public interest through eliminating misunderstandings
17、 between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for their particular need. The existence of such Standards and Publications shall not in any respect preclu
18、de any member or non-member of TIA from manufacturing or selling products not conforming to such Standards and Publications. Neither shall the existence of such Standards and Publications preclude their voluntary use by Non-TIA members, either domestically or internationally. Standards and Publicati
19、ons are adopted by TIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, TIA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the Standard or Publication. Further details of the developm
20、ent process are available in the TIA Engineering Manual, located at http:/www.tiaonline.org/standards/sfg/engineering_manual.cfm This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of th
21、is Standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations before its use. (From Standards Proposal No. 3-4426-AD5, formulated under the cognizance of the TIA TR-42.7 Subcommittee on Telecommunications Copper Cabling Systems.) Publis
22、hed by TELECOMMUNICATIONS INDUSTRY ASSOCIATION 2003 Standards and Technology Department 2500 Wilson Boulevard Arlington, VA 22201 U.S.A. All rights reserved NOTICE OF DISCLAIMER AND LIMITATION OF LIABILITY The document to which this Notice is affixed (the “Document”) has been prepared by one or more
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CSAT568252005COMMERCIALBUILDINGTELECOMMUNICATIONSCABLINGSTANDARDPART2BALANCEDTWISTEDPAIRCABLINGCOMPONENTSADDENDUM5CORRECTIONSTOTIAEIA568B2FIRSTEDITIOPDF

链接地址:http://www.mydoc123.com/p-621642.html