CSA C22 2 NO 208-2014 Fire alarm and signal cable (Third Edition).pdf
《CSA C22 2 NO 208-2014 Fire alarm and signal cable (Third Edition).pdf》由会员分享,可在线阅读,更多相关《CSA C22 2 NO 208-2014 Fire alarm and signal cable (Third Edition).pdf(36页珍藏版)》请在麦多课文档分享上搜索。
1、C22.2 No. 208-14Fire alarm and signalcableLegal Notice for StandardsCanadian Standards Association (operating as “CSA Group”) develops standards through a consensus standards development process approvedby the Standards Council of Canada. This process brings together volunteers representing varied v
2、iewpoints and interests to achieve consensusand develop a standard. Although CSA Group administers the process and establishes rules to promote fairness in achieving consensus,it doesnot independently test, evaluate, or verify the content of standards.Disclaimerand exclusion of liabilityThis documen
3、t is provided without any representations, warranties, or conditions of any kind, express or implied, including, without limitation,implied warranties or conditions concerning this documents fitness for a particularpurpose or use, its merchantability, or its non-infringementof any third partys intel
4、lectual property rights. CSA Group does not warrant the accuracy, completeness, or currency of any of the informationpublished in this document. CSA Group makes no representations or warranties regarding this documents compliancewith any applicablestatute, rule, or regulation.IN NO EVENT SHALL CSA G
5、ROUP, ITS VOLUNTEERS, MEMBERS, SUBSIDIARIES, OR AFFILIATED COMPANIES, OR THEIR EMPLOYEES, DIRECTORS, OROFFICERS, BE LIABLE FOR ANY DIRECT, INDIRECT, OR INCIDENTAL DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES,HOWSOEVER CAUSED,INCLUDING BUT NOT LIMITED TO SPECIAL OR CONSEQUENTIAL DAMAGES, LOST REVENUE,BU
6、SINESS INTERRUPTION, LOST OR DAMAGED DATA,OR ANY OTHER COMMERCIAL OR ECONOMIC LOSS,WHETHER BASED IN CONTRACT, TORT (INCLUDING NEGLIGENCE), OR ANY OTHER THEORY OFLIABILITY, ARISING OUT OF OR RESULTING FROM ACCESS TO OR POSSESSION OR USE OF THIS DOCUMENT, EVEN IF CSA GROUP HAS BEENADVISED OF THE POSSI
7、BILITY OF SUCH DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES.In publishing and making this document available, CSA Group is not undertaking to render professional or other servicesfor or on behalf of anyperson or entity or to perform any duty owed by any person or entity to another person or entity. The
8、 information in this document is directedto those who have the appropriate degree of experience to use and apply its contents, and CSA Group accepts no responsibility whatsoeverarising in any way from any and all use of or reliance on the information contained in this document.CSA Group is a private
9、 not-for-profit company that publishes voluntary standards and related documents. CSA Group has no power, nor does itundertake, to enforce compliancewith the contents of the standards or other documents it publishes.Intellectualpropertyrights and ownershipAs between CSA Group and the users of this d
10、ocument (whether it be in printed or electronic form), CSA Group is the owner, or the authorizedlicensee,of all works contained herein that are protected by copyright, all trade-marks (except as otherwisenoted to the contrary), and allinventions and trade secrets that may be contained in this docume
11、nt, whether or not such inventions and trade secrets are protected by patentsand applications for patents. Without limitation, the unauthorized use, modification, copying, or disclosure of this document may violate lawsthat protect CSA Groups and/or others intellectual property and may give rise to
12、a right in CSA Group and/or others to seek legal redress forsuch use, modification, copying, or disclosure. To the extent permitted by licence or by law, CSA Group reserves all intellectual property rights inthis document.Patent rightsAttention is drawn to the possibility that some of the elements o
13、f this standard may be the subject of patent rights. CSA Group shall not be heldresponsible for identifying any or all such patent rights. Users of this standard are expressly advised that determination of the validity of any suchpatent rights is entirely their own responsibility.Authorizeduse of th
14、is documentThis document is being provided by CSA Group for informational and non-commercial use only. The user of this document is authorized to doonly the following:If this document is in electronic form: load this document onto a computer for the sole purpose of reviewing it; search and browse th
15、is document; and print this document if it is in PDF format.Limited copies of this document in print or paper form may be distributed only to persons who are authorized by CSA Group to have such copies,and only if this Legal Notice appears on each such copy.In addition, users may not and may not per
16、mit others to alter this document in any way or remove this Legal Notice from the attached standard; sell this document without authorization from CSA Group; or make an electronic copy of this document.If you do not agree with any of the terms and conditions contained in this Legal Notice, you may n
17、ot load or use this document or make anycopies of the contents hereof, and if you do make such copies, you are required to destroy them immediately. Use of this document constitutesyour acceptanceof the terms and conditions of this Legal Notice.Standards UpdateServiceC22.2 No. 208-14July 2014Title:
18、Fire alarm and signal cableTo register for e-mail notification about any updates to this publication go to shop.csa.ca click on CSA Update ServiceThe List ID that you will need to register for updates to this publication is 2423207.If you require assistance, please e-mail techsupportcsagroup.org or
19、call 416-747-2233.Visit CSA Groups policy on privacy at csagroup.org/legalto find out how we protect your personalinformation.ISBN 978-1-77139-636-3 2014 CSA GroupAll rights reserved.No part of this publication may be reproduced in any form whatsoever withoutthe prior permission of the publisher.Pub
20、lished in July 2014 by CSA GroupA not-for-profit private sector organization5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5N6To purchase standards and related publications, visit our Online Store at shop.csa.caor call toll-free 1-800-463-6727 or 416-747-4044.TMA trade-mar k of the C
21、anadian S tandards Association, operating as “CSA Group”Fire alarm and signal cableC22.2 No. 208-14C22.2 No. 208-14Fire alarm and signal cableJuly 2014 2014 CSA Group 1ContentsTechnical Committee on Wiring Products 3Subcommittee on Control, Instrument, Communication,and Marine Cables 5Preface 81 Sco
22、pe 102 Reference publications 113 Definitions 124 Construction 124.1 Conductors 124.1.1 General 124.1.2 Uncoated copper wires 124.1.3 Tin- or lead-alloy-coated annealed copper wires 124.1.4 Nickel-coated copper 124.1.5 Silver-coated copper 124.1.6 Sizes 134.1.7 Stranding 134.1.8 Separator 134.1.9 Di
23、ameter and area 134.2 Insulation 134.2.1 General 134.2.2 Thickness 134.3 Assembly of multiple-conductor cables 144.4 Binder or separator 144.5 Conductor identification 144.6 Bonding conductor 144.7 Shield 144.7.1 General 144.7.2 Composition of a shield 144.7.3 Coverage of a shield 154.7.4 Tape shiel
24、d and drain wire 154.8 Jacket 154.9 Mechanical protection (optional) 154.9.1 General 154.9.2 Interlocked armour 154.9.3 Aluminum or copper sheath 164.9.4 Overall covering over interlocked armour, aluminum, or copper sheath 165 Marking 165.1 Marking on cable 165.2 Marking on tags 166 Tests 17C22.2 No
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CSAC222NO2082014FIREALARMANDSIGNALCABLETHIRDEDITIONPDF

链接地址:http://www.mydoc123.com/p-621243.html