CSA C22 2 NO 117-1970 Room air conditioners (Second Edition General Instruction No 1 February 1974).pdf
《CSA C22 2 NO 117-1970 Room air conditioners (Second Edition General Instruction No 1 February 1974).pdf》由会员分享,可在线阅读,更多相关《CSA C22 2 NO 117-1970 Room air conditioners (Second Edition General Instruction No 1 February 1974).pdf(38页珍藏版)》请在麦多课文档分享上搜索。
1、C22.2 No. 117-1970(reaffirmed 2012)Room air conditionersBlank pageGeneral Instruction No. 1C22.2 No. 117-1970February 1974Note: General Instructions for CSA Standards are now called Updates. Please contact CSA Information Products Sales or visit shop.csa.ca for information about the CSA Standards Up
2、date Service.Title: Room air conditioners originally published August 1970The following revisions have been formally approved.Revised Clauses 4.2.2.4, 4.4.2.3, and 6.16.2New NoneDeleted None Update your copy by inserting these revised pages.Keep the pages you remove for reference.C22.2 No. 117-1970
3、Room Air Conditioners The following revisions, covering Clauses 4.2.1.6, 4.2.2.4, and 6.19 and Figure 1, have been formally approved. Publication Date July 2007 . Clause 4.2.1.6 Revise Clause 4.2.1.6 to read as follows: 4.2.1.6 Enclosures or parts thereof shall be considered to comply with Clause 4.
4、2.1.5 provided that they comply with the flammability requirements for 5VA materials in accordance with CAN/CSA-C22.2 No. 0.17-00, Evaluation of Properties of Polymeric Materials. July 2007 Revision No. 7 C22.2 No. 117-1970 . Clause 4.2.2.4 Revise Clause 4.2.2.4 to read as follows: 4.2.2.4 Louvers o
5、r other openings in enclosures for electrical parts other than motors shall be located, constructed, or baffled so as to prevent the emission of flame or molten metal from the air conditioner, and from an individual enclosure within the air conditioner if such an emission could cause a fire hazard b
6、y igniting materials within the air conditioner. Note: A hazard due to ignition of materials within the air conditioner is considered to be unlikely if (a) the materials comply with the flammability requirements of Clause 4.2.1.6; (b) the materials are normally acceptable as electrical insulation of
7、 components complying with the applicable Part II Standard of the Canadian Electrical Code; or (c) materials other than those specified in (a) or (b) above are judged to be present in an insignificant amount. July 2007 Revision No. 8 C22.2 No. 117-1970 . Clause 6.19 Deleted July 2007 Revision No. 9
8、C22.2 No. 117-1970 . Figure 1 Deleted July 2007 Revision No. 10 C22.2 No. 117-1970 . C22.2 No. 117-1970 Room Air Conditioners The following revisions, covering Clauses 2.1, 4.5.7, and 5.4, have been formally approved. Publication Date September 2005 . Clause 2.1 Add the following definitions to Clau
9、se 2.1: Arc-fault circuit interrupter (AFCI) a device intended to mitigate the effects of arcing faults by functioning to de-energize the circuit when an arc fault is detected. Leakage-current detector-interrupter (LCDI) a device that senses leakage current flowing between or from the attached cord
10、conductors and interrupts the circuit at a predetermined level of leakage current. Note: LCDIs may be integrated into cord sets or power supply cords. September 2005 Revision No. 4 C22.2 No. 117-1970 . Clause 4.5 Add the following clause: 4.5.7 A cord-connected single-phase room air conditioner shal
11、l be provided with a factory-installed LCDI or AFCI protection to reduce the risk of fire caused by arcing faults in the power supply cord. The LCDI or AFCI shall de-energize all current-carrying parts when arcing faults are detected within the power supply cord, and shall be installed as an integra
12、l part of the attachment plug cap or located in the supply cord within 300 mm (12 in) of the attachment plug cap. September 2005 Revision No. 5 C22.2 No. 117-1970 . Clause 5 Add the following clause: 5.4 A cord-connected room air conditioner shall be marked to indicate that a damaged power supply co
13、rd shall be replaced with a new supply cord obtained from the product manufacturer and not repaired. September 2005 Revision No. 6 C22.2 No. 117-1970 . Clause 4.2.2.4 Revise Clause 4.2.2.4 to read as follows: 4.2.2.4 Louvers or other openings in enclosures for electrical parts other than motors shal
14、l be located, constructed, or baffled so as to prevent the emission of flame or molten metal from the air conditioner, and from an individual enclosure within the air conditioner if such an emission could cause a fire hazard by igniting materials within the air conditioner. NOTE: A hazard due to ign
15、ition of materials within the air conditioner is considered to be unlikely if: (a) The materials are self extinguishing when tested by a procedure such as described in Clause 6.19; (b) The materials are normally acceptable as electrical insulation of com- ponents complying with the applicable Standa
16、rd of Part II of the Code; or (c) Materials other than those specified in (a) or (b) above are judged to be present in an insignificant amount. - Publication Date February 28, 1974 Effective Date February 28, 1974 Revision No. I C22.2 No. 1171970 Clause 4.4.2.3 .- Revise Clause 4.4.2.3 to read as fo
17、llows: 4.4.2.3 Tubing used in the construction of refrigerant-containing parts such as an evaporator or condenser coil which is adequately protected by the inherent construction shall comply with the pressure test specified in Clause 6.16, and shall have a wall thickness not less than 0.016 inch, ex
18、cept that the minimum thickness requirement does not apply to coils of finned copper tubing which: (a) Are each subjected to a pressure test during manufacture at a pres- sure, for condenser coils, not less than 125 per cent of the maxi- mum pressure dveloped in the temperature test specified in Cla
19、use 6.5; and at a pressure, for evaporator coils, not less than 20 per cent of the test pressure specified in Clause 6.16; (b) Have inlet and outlet tube wall thickness of not less than 0.016 inch; (c) Have hairpin turns and return bends protected from damage dur- ing assembly and after installation
20、 in the air codaitioner. Publication Date February 28, 1974 Effective Date February 28, 1974 Revision No. 2 C22.2 No. 1171970 Clause 6.16.2 Add a second paragraph to Clause 6.162 as follows: Such parts that are made of finned copper tubing with a wall thickness less than 0.016 inch, as provided in C
21、lause 4.4.2.3, shall also be capable of withstanding without failure a pressure equal to three times the low side pressure developed in the abnormal temperature (fan motor failure) test specified in Clause 6.7, including the pressure which follows stopping of t1 compressor. Publication Date February
22、 28, 1974 Effective Date February 28, 1974 Revisio, IV.:. J C222 No. 1171970 CSA STANDARD C22.2 No. 1171970 ROOM AIR CONDITIONERS FORMING PART OF CANADIAN ELECTRICAL CODE. PART II SAFETY STANDARDS FOR ELECTRICAL EQUIPMENT PUILIS1UD. AUGUST. 1910 IT ThE CANADIAN STAIIDAADS ASSOCIATiON (INCORPORATED 1
23、919) 17$ I!XDAL! IOULEYARD REXOALE . OKTAAIO. CANADA DATE EFfECTIVE NOVEMIER 30. 1970 DATE. MANDATORY NOVEMIER 30. 1970 COPYRIGRT REGISTERED, CANADA. 1960 CSA CERTIFICATION The Canadian Standards Association provides certification services for manufacturers who, under licence from CSA, wish to use t
24、he appro- priate registered CSA Marks on certain products of their manufacture to indicate conformity with a CSA Standard. CSA Certification for a number of products is provided on a voluntary basis in the interest of maintaining agreed-upon standards of quality, performance, interchangeability, or
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CSAC222NO1171970ROOMAIRCONDITIONERSSECONDEDITIONGENERALINSTRUCTIONNO1FEBRUARY1974PDF

链接地址:http://www.mydoc123.com/p-621194.html