1、 COE CEAGS 16740A I 3515711i5 0534472 688 R . DEPARTMENT OF THE ARMY CEAGS-16740A (December 1994) U.S. ARMY CORPS OF ENGINEERS Superseding CEAGS 16740A (October 1992) ABRIDGED GUIDE SPECIFICATION FOR MILITARY CONSTRUCTION . SECTION 16740A TELEPHONE SYSTEM, PRE-WIRING 12/94 PART 1 GENERAL NOTE: See A
2、dditional Notes A through D. 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. designation only. The publications are referred to in the text by basic ELECTRONIC INDUSTRIES ASSOCIATION (EIA) EIA 568 EIA TSB 36 EIA TSB 40-A (1991) Commercial Buil
3、ding Telecommunications Wiring Standard (1991) Additional Cable Specifications for Unchielded Twisted Pair Cables (1994) Additional Transmission Specifications for Unshielded Twisted-Pair Connecting Hardware INSULATED CABLE ENGINEERS ASSOCIATION (ICEA) ICEA S-80-576 (1988) Communications Wire and Ca
4、ble for wiring of Premises NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) NFPA 70 (1993) National Electrical Code UNDERWRITERS LABORATORY (UL) UL 50 1.2 SYSTEM DESCRIPTION (1992; Rev thru Nov 1994) Enclosures for Electrical Equipment A telecommunications wiring system consisting of inside plant cables
5、and other auxiliary equipment shall be provided. 1.3 SUBMITTALS Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Government approval is required for submittals with a designation; submittals having an lfFIOIt designation are for information only. The
6、following shall be submitted in accordance with Section 01300 SUBMITTAL DESCRIPTIONS: SD-04 Drawings Telephone Pre-wiring System; GA. Detail drawings shall include a complete list of equipment and material, including manufacturers descriptive and technical literature, performance charts and curves,
7、catalog cuts, and installation instructions. Detail drawings shall contain complete wiring diagrams and any other details required to demonstrate that the system has been coordinated and will properly function when connected to the dial central office. shall show proposed layout and equipment relati
8、onship to other parts of the work including clearance for maintenance and operations. Drawings System drawings showing final configuration, including location, type, gauge, and block and terminal assignment of inside wiring, and floor plan layout for the equipment room, after installation. SD-06 Ins
9、tructions Manufacturers Recommendations; GA. Where installation procedures, or any part thereof, are required to be in accordance with the recommendations of the manufacturer of the material being installed, printed copies of these recommendations shall be provided prior to installation. Installatio
10、n of the item will not be allowed to proceed until the recommendations are received and approved. SD-09 Reports Test Reports; I* Test reports in booklet form showing field tests performed to prove compliance with the specified performance criteria, upon completion and testing of the installed system
11、. SD-14 Certificates Horizontal Cables; 3. Backbone Cables; I* - 1. Connecting Hardware; I* Telecommunication Outlets; 3. Communication Cabinets; Manufacturers certificate indicating compliance with transmission and reliability requirements. conform to the standards or publications and requirements
12、of CFR, EIA, ICEA and UL, certificates shall be provided attesting that the items furnished under this section of the specification conform to the specified requirements. Where equipment or materials are specified to 1.4 DELIVERY AND STORAGE Equipment delivered and placed in storage shall be stored
13、with protection from the weather, humidity and temperature variation, dirt and dust, or other contaminants. PART 2 PRODUCTS Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-COE CEAGS Lb740A 3535789 0533474 450 H 2.1 STANDARD PRODUCTS Materials and equ
14、ipment shall be the standard products of a manufacturer regularly engaged in the manufacture of the products and shall be the manufacturers latest standard design that has been in satisfactory use for at least 2 years prior to bid opening. 2.2 WIRING SYSTEM The category for cable, jacks and blocks s
15、hould be the same throughout each circuit and system. Specify more than two categories only if providing two systems requiring different categories. general, Category 3 (up to 1OMHz transmission) should be used for voice circuits and Category 5 (up to 1OOMHz) should be used for data circuits. Verify
16、 this criteria with the user. In For specialized circuits such as pay phones in dorms and other sleeping quarters coordinate with the local telephone company. For applications where cables will not be in conduit, and are in a plenum environment, specify Type 2 for horizontal cable and Type 4 for bac
17、kbone cable. If in conduit, or not in a plenum, Type 1 for horizontal cable and Type 3 for backbone cable should be specified. Ensure that the NEC 60 percent maximum conduit fill is considered when sizing cables. When sizing the cables and determining the category, keep in mind whether the system is
18、 voice-only or voice-data. Use pin/pair configuration T568A unless the host facility has standardized on T568B NOTE: See Additional Note E. The wiring system shall be in conformance with EIA 568. 2.2.1 Horizontal Cables Horizontal cables between the telecommunication outlet and the connecting hardwa
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- COECEAGS16740A1994TELEPHONESYSTEMPREWIRING 电话 系统 布线 PDF

链接地址:http://www.mydoc123.com/p-620629.html