1、- = 3515789 0013887 145 *- - DEPARTMENT OF THE AIiW OFFICE OF THE CHIEF OF EWIWLBRII 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. SECTION 13 - CMBTAL BUILRIWS 1 INDEX GENERAL DESIGN REQUIREMENTS IMFORMATION DRAWINGS DESCRIPTIVE DATA DELIVERY AND STORAGE BUILDING COUPONEIT8 SHOP PAINTING FACTORY COLOR PINISI E
2、RECT ION FIELD PAINTIWC GUARANTEE i Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-W 3535789 0033888 083 D CE-R-13.1 July 1985 - SECTION 13 METAL BUILDINGS 1. GENERAL: Metal building components shall be the product of a recognized metal building man
3、ufacturer. Design with vertical walls and gable single- slope roofs and with single-span single-span or multiple-span structures of one of the following types: Type I Type II - Rigid frame. Type III - Self-framing. - Column with truss or column with beam. frame. Multiple-span structures are building
4、s with interior columns shed extensions. Furnish a building that is a standard size indicated and larger only to the closest standard size. Use in 12 inches or steeper. or buildings with not smaller than roof slope 1 inch 2. DESIGN REQUIREMENTS: 2.1 Loadings: Design buildings for dead load, live loa
5、ds, and combina- tions of loads in accordance with the Metal Building Systems Manual (1981 and Errata) except as modified herein. Reduction due to tributary loaded area will not be permitted. Use the following live loads: Vertical psf. Design wind velocity, including gusts, of miles per hour. Auxili
6、ary loads consisting of 2.2 Foundations: Design foundations for an allowable soil bearing pressure of - psf. Set bottom of footing at least feet below base plates. Use a factor of safety of 1.5 for uplift, and a 2,500 psi concrete compressive strength . in. 2.3 Gutters and downspouts: Design for a r
7、ainfall rate of - per hour for a 5-min. duration. sq. ft. 2.4 Louvers: Fixed-blade Adjustable type, design with - minimum net open area, rainproof, and to resist vibration at a volume rate of cfm. 2.5 Circular roof ventilators: Gravity directional stationary revolving type, design each for a minimum
8、 capacity of 16001 cfm based on 5 mph wind velocity and a 10 degrees F. indoor-outdoor temperature difference and without screens. Provide with dampers. 2.6 Continuous roof ventilators: Ridge mounted, gravity type, design each 10 ft. section for a minimum capacity of 2,500 cfm based on a 5 mph wind
9、velocity and a 10 degrees F., indoor-outdoorFemperature difference and without screens. Provide with dampers. 13 -1 - Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3535789 O033889 TLB CE-R-13.1 July 1985 rr) I 2.7 Framing and structural members: St
10、ructural steel members shall be designed in accordance with AISC publication, Specification for the Design, Fabrication, and Erection of Structural Steel for Buildings. Structural cold-formed steel framing members shall be designed in accordance with AIS1 publication, Specification for the Design of
11、 Cold-Formed Steel Structural Members. Aluminum framing and structural members shall conform to the Alum. Assoc. publication, Aluminum Standards and Data, and shall be designed in accordance with the Alum. Assoc. publication, Specifications for Aluminum Structures. Framed openings shall be designed
12、to structurally replace the covering and framing displaced. Welding of steel shall be in accordance with AWS publication Dl.1-85, and welding of aluminum shall be in accordance with The Alum. Assoc. publication, Specifications for Aluminum Structures. 3. INFORMATION DRAWINGS : a. The term “informati
13、on drawings“ includes drawings, diagrams, layouts, schematics, descriptive literature, illustrations, schedules, performance and test data, and similar materials furnished by the Contractor for information only, to explain in detail specific portions of the work required by the contract. , b. The Co
14、ntractor shall coordinate all information drawings and review them for accuracy, completeness, and compliance with contract requirements and shall indicate iis approval thereon as evidence of such coordination and review. Information drawings submitted to the Contracting Officer without evidence of
15、the Contractors approval may be returned for resubmission. c. The Contractor shall submit four copies of all information drawings, to include the following: (list) 4. DESCRIPTIVE DATA: Furnish data for the following items either on the shop drawings or separately: Accessories, each type of flashing,
16、 trim, closures, caps, and similar items; roof and wall covering, configurations and colors available, and one piece of each type to be used, 9 in. long, full width; fasteners; insulation; skylight panel; wall liner; and window, doors, louvers, ventilators, gutters, and downspouts. 5. DELIVERY AND S
17、TORAGE: Deliver materials dry and undamaged, and store out of contact with the ground. Cover materials, except framing and struc- tural members with weathertight coverings and keep dry. Provide good air circulation and protection from surface staining for roof and wall covering s hee t s. 6. BUILDIN
18、G COMPONENTS: 6.1 General: Approved metal building components shall be furnished by an authorized dealer of the manufacturer and shall be the design and quality as designated by that manufacturer. Where components are furnished or erected by other than the authorized building dealer or supplier of t
19、he building components, supervision of erection shall be as specified hereinafter. 13 -2 - Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-m 3535789 0033890 73T m CE-R-13.1 July 1985 6.2 Bolts and connections: Use standard types and sizes for anchor
20、bolts and for erection and connection of framing and structural members. Seal each fastener with a 1/8-in. thick gasket of neoprene or similar weather-resistant, resilient material. The use of self-drilling, self-tapping fasteners with effective power tools by experienced workmen is permitted. 6.3 P
21、anel siding and roofing: Sheet metal covering shall be of gage steel or of inch thick aluminum sheet metal. The steel sheet metal shall be coated with zinc galvanizing and the aluminum sheet metal shall have a colored, factory finish. Sheet metal panel joint configuration shall be scanding-seam for
22、adjacent sheets or interlocking ribs for securing adjacent sheets. Width of sheets with standing-seam configuration shall provide not less than 24 inches of coverage in place; width of sheets with interlocking ribs shall provide not less than 12 inches of coverage in place. Depth of configurations f
23、or roof covering shall be not less than 1 inch. Length of sheets shall be sufficient to cover the entire length of any unbroken roof slope or the entire height of any unbroken wall surface when such slope or height is 30 feet or less. Sheets in excess of 30 feet shall have design provisions for ther
24、mal expansion and contraction. Ridge end of panels and intersections of roofing and vertical surfaces shall have pan-break ends or equivalent metal flashing in addition to profile plug closures. Field cut sheets shall be square cut, except gable end wall sheets may be cut in the shop to correspond t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- COECER1311985METALBUILDINGS 金属 建筑物 PDF