COE 2 13-1966 FENCING《篱笆》.pdf
《COE 2 13-1966 FENCING《篱笆》.pdf》由会员分享,可在线阅读,更多相关《COE 2 13-1966 FENCING《篱笆》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、DEPARTMENT OF DEFENSE GUIDE SPECIFICATIONS FOR MILITARY FAMILY HOUSING FEN CI N G Department of the Army Guide Specification OCE GSH 2.13 Department of the Navy Guide Specification FAC GSH 2.13 Department of the Air Force Manual AFM 85-25, Sec. 2.13 Provided by IHSNot for ResaleNo reproduction or ne
2、tworking permitted without license from IHS-,-,-W 3515789 0014220 818 W 4270.21 - SPEC 2.13 N2 5 May 1985 GUIDE SPECIFICATIONS FOR MILITARY FAMILY HOUSING FENCING GENERAL NOTES The Departments of the Army, Navy and Air Force have collaborated in the preparation of this Guide Specificatan. Its conten
3、ts and arrangements conform generally to the (17) “CSI Masterformat - Master List of Section Titles and (25) Numbers (MP-2-l),“ 10 Mar 1983 of the Construction Speci- (17) fications Institute. (17) In accordance with the CSI Masterformat, identify each Section by a number and a letter (see Index of
4、Divisions and . Sections). The number will be that of the Division under which the Section is located. The letters following the number will begin with “A“ and continue alphabetically, as necessary USE AND INSTRUCTION: This Guide Specification shall be used in the preparation of project specificatio
5、ns for Military Family Housing in ac- cordance with current directives and instructions. It shall not be made a part of another specification by reference. Each project Architect- Engineer shall assure that complete coverage of the WOKK involved is specified, and shall further assure that Co-ordinat
6、ion with the drawings is accomplished. SELECTION OF MATERIALS: It is intended that architects and engineers for military family housing projects be permitted to select from this Guide Specification the materials and equipment which, in their professional judg- ment, are sui table for specif ic proje
7、cts. Contractor opinions included in this Guide Specification shall not be deleted unless economic and engineering evaluations indicate that the options are not justified for a specific project. Newly developed materials and methods not included in this Guide Specifica- tion may be used in limited a
8、pplication with prior clearance of the Military Departments involved. (Each Military Department shall ensure that prohibi- ted materials are not included in project specifications.) Such new materials or methods may not be used extensively until the quality and durability have been proven and approp
9、riate specifications have been included in this Guide Specification. In selecting the quality standards for materials and equipment, consideration should be given to the impact that certain materials may have on the construc- tion and maintenance cost of the over-all project. Notes, Page i - - -.* S
10、ection 2 “REMOVE - DO NOT INCLUDE NOTE SHEETS IN TE PROJECT SPECIFICATIONS“ Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- 3515789 0014221 754 4270.21 - SPEC Jul 1, 66 GULDE SPECIFICATIONS FOR MILITARY FAMILY HOUSING FENCING Fencing will be located
11、 in $he project specifications as one of the Sections under Division 2 - “Site Work,“ and be numbered ac co r din gly . NOTES ON THE USE OF THIS SPECIFICATION SUGGESTIONS AND RECOMMENDA- TIONS: This section shall be included in the specifications when fencing is required for safety and/or screening
12、of a military family housing project. Security fencing is specifically ex- cluded from this section of the Mili- tary Family Housing Guide Specifica- tion s. The drawings shall incorporate a specific layout of fencing. Locations of straight-line and corner-post brac- ing shall be indicated. Requirem
13、ents of fence type, height of fence, swing of gates, and sizes shall be provided in layouts. For military family housing projects requiring security fencing for electri- cal substations or similar installations, the appropriate Departmental Guide Specification for security fencing util- ized in mili
14、tary construction projects shall be used as guidance. trical equipment fence enclosures are required, drawings shall provide for electrical clearances- between fence and equipment and wiring and equipment foundations to allow proper width for truck aisles. Where elec- If the area to be fenced has an
15、 irregular surface, drainage structures and fence line grading for rugged areas will be handled separately and the profile shall be included. This section may be expanded to include other types of fencing necessary for screen enclosures or unusual boundary conditions. Referenced Specifications: NOTE
16、 in the project specifica- tions, list the specifications and stand- ards by their current titles, numbers and letters. Inapplicable Mate rial: Delete materials not required. Chain Link Fencing: The .U standard height of chain - link fencing for military family hous- ing projects shall be 42 inches.
17、 When a specific .project requires a greater height for added safety, but not for security purposes, the height may be increased to 72 inches. Toprails or Wire: The toprails shall be deleted and a top tension wire substituted where appearance is not important or where the chain link fence is adja- c
18、ent to screen planting. A bottom reinforcing wire shall be specified with either a toprail or a top rein- forcing wire. Screen Fencing: Details for wood or masonry screening shall be completely indi- cated on the drawings, and the method of canstructian shall be accomplished in accordance with the a
19、ppropriate section of these specifications. Section 2 . , Notes, Page ii - iiMV- DU NOT INCLUDE NOTE SHEETS IN THE PROJECT SPECIFICATIONI Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-m 3515789 O014222 b90 4 8 4270.21 - SPEC 2.13 N2 5 May 1985 GUID
20、E SPECIFICATIONS FOR MILITARY FAMILY HOUSING SECTION 2 - FENCING f 1. SCOPE OF WORK: (A) WORK INCLUDED: This section includes fencing complete as indicated. 2. REFERENCED SPECIFICATIONS AND STANDARDS: (13) (A) APPLICABLE PUBLICATIONS: The publications listed below form a part (13) of this specificat
21、ion to the extent referenced. The publications are (13) referred to in the text by the basic designation only. (13) (1) Federal Specification: Fencing, Wire and Post Metal (And Gates, Chain-Link Fence Fabric, and Accessories) (General Specification). (2) American Society for Testing and Materials (A
22、STM): (14) A 123-78 Zinc (Hot-Galvanized) Coatings on Products Fabricated from Rolled, Pressed, and Forged Steel Shapes, Plates, Bars, and Strip. Zinc-Coated Steel Chain-Link Fence Fabric. Weight of Coating on Aluminum- Coated Iron or Steel Articles. Aluminum-Alloy Bar, Rod, and Wire (21) (3) Delete
23、d. , Page 1 - Section 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-il ,%, = m 3535789 0034223 527 m 4270.21 - SPEC 2.13 R1 /N2 2 February 1983 3. MATERIALS : FENCING (A) STANDARD PRODUCTS: Materials provided shall be standard catalog products of
24、 manufacturers regularly engaged in manufacture of products conforming to these specifications. (21) (BI CHAIN LINK FABRIC: Chain link fencing fabric shall be one of the following with a 2 inch mesh fabric height and edge finish as indicated: (21) (1) Galvanized Steel: Shall conform to ASTM A 392, 9
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- COE2131966FENCING 篱笆 PDF