1、CEPT T/CS*49-01*E = 232b414 00048b8 8 0 TCs49-01 Page E 1 Recommendation T/CS 49-01 (Ostend 1979, revised in Vienna 1982 and Montpellier 1984) SYSTEM L1 LINE SIGNALLING OVER INTERNATIONAL INTER-PRIVATE AUTOMATIC BRANCH EXCHANGE LINES Recommendation proposed by Working Group T/WG 1 1 “Switching and S
2、ignalling” (CS) Text of the Recommendation revised adopted by Commission “Telecommunications” “The European Conference of Postal and Telecommunications Administrations, considering that there is an increasing need for the interconnection of private automatic branch exchanges located in different cou
3、ntries by means of international leased lines; that these international connections between private automatic branch exchanges should permit a fully automatic service between extensions connected to the private automatic branch exchanges conceined and auihorised for international trafic; O - that CC
4、ITT Recommendations Q. 1 i and Q.2 2, since they are not directly applicable to international leased circuits, cannot cover the automatic service either; that a proliferation of private systems designed by suppliers tends to make operation and maintenance more dificult, recommends that the members,
5、when introducing international interconnections over links between analogue transmission interfaces of private automatic branch exchanges, use the System L1 line signalling, which comprises the signals, equipment functions and procedures specified in the following. The requirements refer to the inte
6、rfaces between the link and the outgoing or incoming private automatic branch exchange. The private automatic branch exchanges at both ends are regarded as functional units and no specifications are included on the ways and means for the provision of the functions concerned.” O 1. 1.1. 1.2. 1.3. 1.4
7、. 1.5. 1.6. 1.7. 1 .s. PRINCIPLES AND FIELDS OF APPLICATION The line signalling system is to provide automatic and semi-automatic working between private automatic branch exchanges (PABXs) in different countries, via terrestrial circuits. The use of the system over satellite circuits and over compos
8、ed terrestrial satellite circuits is possible, provided that echo-suppressors or echo-cancellers needed are installed on the customer side between the hybrid and the 2,280 Hz sending and receiving equipment. The signalling system is a single voice,frequency (I vfj tone-on-idle line signalling system
9、 using a signalling frequency of 2,280 Hz. The use of voice frequency signals renders the system suitable for all voice transmission media, except those using speech interpolation. The system is intended for use on both-way inter-PABX circuits. Either decadic pulsing or multifrequency interregister
10、signalling may be used with the system (see Explana- tory notes on Group 49 Recommendations preceding this Recommendation). The provision of particular line signals will depend upon the requirements of the associated interregister signalling system. The system operates on a four-wire basis, forward
11、and backward signals being segregated by utilising the four-wire circuit as two separate signalling paths. The send pair to which signals are applied is the receive pair at the distant end. Figure 1 (T/CS 49-01) shows a termination at one end. In addition to the application or removal of signalling
12、frequency (tone-on and tone-off) in continuous form, the transmission of pulses of signalling frequency is applied. When in the idle condition, the signalling frequency applied to the line is reduced in power level to conform to the transmission loading requirements of CCITT Recommendation Q. 15 3.
13、The line signalling operates on a link-by-link basis and may be used to establish a multi-link tandem connection using one or more private automatic exchange(s) as a transit switch. Im accordance with CCITT Recommendation 4.25 4, the signals are contaned within the appropriate link and are not allow
14、ed to spill over into subsequent or preceding links. Edition of May 15, 1986 CEPT T/CS*4-OL*E = 232b4L4 00048b T T/CC49-01 E Page 2 2280 Hz SENDER7 1 SEND SIGNALLING / PATH PABX TERMINATION PABX I 4 -?NIRE CIRCUIT I y RECEIVE SIGNALLING i PATH PABX TERMINATION 2280 Hr SIGNAL OUTPUT 1.9. 1.10. 2. 3.
15、3.1. 3.2. Figure 1 (T/CS 49-0 1). Four-wire private automatic branch exchange termination. The maximum number of tandem connections over which a call may be set-up is determined by the type of interconnecting circuits and is subject to mutual agreement by the parties concerned. However, all circuits
16、 used in a tandem connection should be to the standard of CCITT Recommendations G.171 5 and M.lO1O to M.1060 6. Forward signals may be passed while speech or audible indications (tones or recorded announcements) are being received in the backward direction. A through speech path shall be provided in
17、 the backward direction of transmission during call Set-up. SYSTEM L1 LINE SIGNALS The names and meanings of the signals specified for System LI line signalling are in accordance with Recommendation T/CS 41-01 7. The following signals may be provided: Seizing signal. - Seizing-acknowledgment/Proceed
18、-to-send signal (see Section 5.2.). - Clear-forward signal. Clear-back signal. - Cleared signal. - Answer signal. - Forward-service-request-recall signal. - Forward-link-recall signal. - Backward-service-request-recall signal. Backward-link-recall signal. - Intrusion signal. - End-of-intrusion signa
19、l. All signals above, except the proceed-to-send signal, are supervisory signals. LINE SENDING AND DETECTING REQUIREMENTS General With the tone-on-idle signalling method, a signalling tone is sent continuously over the transmission channels in both directions when the circuit is idle. The presence o
20、f the tone indicates to both ends that the circuit is available and free to accept calls. This idle line signal condition represents the idle state of the circuit. The tone is removed in the forward direction at the moment of seizure and in the backward direction when the first backward signal needs
21、 to be transferred. Restoring tone in the forward direction creates a total of four line signal conditions. The transition from one line signal condition to another one corresponds to the transfer of a line signal, according to the specifications referred to in Section 2. above. The use of these tra
22、nsitions only, however, does not provide for a sufficient number of signals. Therefore, as a call proceeds, each signal condition on the line may be repeated, and also single and double tone-on pulses may be used. Distinction between different signals having the same characteristics shall be made by
23、 the position of the signal in the sequence of the signalling procedure. Line signai conditions and signalling codes The line signal conditions and the signalling codes shall be as shown in Table 1 (T/CS 49-01). Signal sending and detection requirements are given in Sections 3.3. and 3.4. All signal
24、s sent shall give a true indication of the state the call-handling procedure has reached in the PABX concerned. Edition of May 15, 1986 CEPT T/CS*49-OL*E W 2326434 0004870 b 3.3. 3.3.1. 3.3.2. 3.3.3. 3.3.4. 3.4. TICS 49-01 E Page 3 The provision and use of particular line signals, some of which are
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CEPTTCS4901E1986SYSTEML1SIGNALLINGOVERINTERNATIONALINTERPABXLINES 国际 内部 PABX 系统 L1 PDF

链接地址:http://www.mydoc123.com/p-593059.html