CEN TR 15983-2010 Stationary source emissions - Guidance on the application of EN 14181 2004《固定污染源排放 EN 14181-2004的应用指南》.pdf
《CEN TR 15983-2010 Stationary source emissions - Guidance on the application of EN 14181 2004《固定污染源排放 EN 14181-2004的应用指南》.pdf》由会员分享,可在线阅读,更多相关《CEN TR 15983-2010 Stationary source emissions - Guidance on the application of EN 14181 2004《固定污染源排放 EN 14181-2004的应用指南》.pdf(48页珍藏版)》请在麦多课文档分享上搜索。
1、PD CEN/TR 15983:2010ICS 13.040.40NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWPUBLISHED DOCUMENTStationary source emissions Guidance on the application of EN 14181:2004This Published Documentwas published under theauthority of the StandardsPolicy and StrategyCommittee on 28
2、February2010 BSI 2010ISBN 978 0 580 67970 4Amendments/corrigenda issued since publicationDate CommentsPD CEN/TR 15983:2010National forewordThis Published Document is the UK implementation of CEN/TR15983:2010.The UK participation in its preparation was entrusted to TechnicalCommittee EH/2/1, Stationa
3、ry source emission.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisionsof a contract. Users are responsible for its correct application.Compliance with a British Standard cannot conf
4、er immunityfrom legal obligations.PD CEN/TR 15983:2010TECHNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CEN/TR 15983 January 2010 ICS 13.040.40 English Version Stationary source emissions - Guidance on the application of EN 14181:2004 Emissions de sources fixes - Guide dapplication de lEN 14181
5、:2004 Emissionen aus stationren Quellen - Leitlinien zur Anwendung der EN 14181:2004 This Technical Report was approved by CEN on 1 December 2009. It has been drawn up by the Technical Committee CEN/TC 264. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus,
6、 Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT
7、 EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2010 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. CEN/TR 15983:2010: EPD CEN/TR 15983:2010CEN/TR 15983:2010 (E) 2 Content
8、s Page Foreword 3Introduction .41 Scope 52 Terms and definitions .53 Symbols and abbreviations 93.1 Symbols 93.2 Abbreviations 104 General guidance on quality assurance and calibration 104.1 General . 104.2 Regulatory framework and standards for monitoring 104.3 Roles and responsibilities . 125 Appl
9、ication of QAL1 . 125.1 General . 125.2 AMS which are not yet installed at the plant . 135.3 AMS which are already installed at the plant . 136 Application of QAL2 and AST 136.1 Tasks within QAL2 and AST 136.2 Location and monitoring provisions for AMS . 146.3 Management system provisions for AMS 14
10、6.4 Specific issues of the functional tests . 147 Calibration and validation of the AMS 167.1 Standard reference methods . 167.2 Calibration using an SRM 167.3 Low-level clusters . 207.4 Peripheral AMS measurements . 217.5 Establishing the calibration function and the test of variability 217.6 Data
11、points outside the calibration range 227.7 Calibrating AMS for NOxand TOC 237.8 Significant changes to operating conditions and fuels 247.9 Significant changes to an AMS . 248 On-going surveillance and quality assurance of AMS (QAL3) 258.1 The necessity for QAL3 258.2 Choosing control charts 258.3 Z
12、ero and span measurements . 268.4 Setting parameters for control charts 29Annex A (informative) An example of a procedure for determining outliers . 31Annex B (informative) Alternative approaches for dealing with low-level clusters of emissions . 34Annex C (informative) kvvalues 36Annex D (informati
13、ve) Shewhart and EWMA control charts 37Bibliography . 43PD CEN/TR 15983:2010CEN/TR 15983:2010 (E) 3 Foreword This document (CEN/TR 15983:2010) has been prepared by Technical Committee CEN/TC 264 “Air quality”, the secretariat of which is held by DIN. Attention is drawn to the possibility that some o
14、f the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. PD CEN/TR 15983:2010CEN/TR 15983:2010 (E) 4 Introduction This CEN Technical Report provides supporting guidance on the application of E
15、N 14181:2004. It is based on the growing experiences with EN 14181:2004 throughout the CEN member countries. EN 14181:2004 specifies three levels of quality assurance (QAL), known as QAL1, QAL2 and QAL3 as well as an Annual Surveillance Test (AST). This Technical Report explains the requirements of
16、these levels of quality assurance to achieve a consistent application of EN 14181:2004. PD CEN/TR 15983:2010CEN/TR 15983:2010 (E) 5 1 Scope This CEN Technical Report provides guidance for applying the European Standard EN 14181:2004. This CEN Technical Report provides guidance only on applying the q
17、uality assurance levels QAL1, QAL2 and QAL3 as well as the Annual Surveillance Test (AST). This CEN Technical Report is an informative document. 2 Terms and definitions For the purposes of this document, the following terms and definitions apply. 2.1 air quality characteristic one of the quantifiabl
18、e properties relating to an air mass under investigation, for example, concentration of a constituent EN 14181:2004, 3.1 2.2 automated measuring system AMS measuring system permanently installed on site for continuous monitoring of emissions EN 14181:2004, 3.2 NOTE 1 An AMS is the automated applicat
19、ion of a monitoring method, which is traceable to a reference method. NOTE 2 Apart from the analyser, an AMS includes facilities for taking samples (e.g. sample probe, sample gas lines, flow meters, regulators, delivery pumps) and for sample conditioning (e.g. dust filter, moisture removal devices,
20、converters, diluters). This definition also includes testing and adjusting devices that are required for regular functional checks. 2.3 calibration function linear relationship between the values of the SRM and the AMS with the assumption of a constant residual standard deviation EN 14181:2004, 3.3
21、NOTE The calibration function is established during QAL2 on stack gases. 2.4 competent authority organisation which implements the requirements of EU Directives and regulates installations, which must comply with the requirements of applicable European Standards EN 15267-1:2009, 3.3 2.5 confidence i
22、nterval (two-sided) when T1and T2are two functions of the observed values such that, being a population parameter to be estimated, the probability Pr(T1 T2) is at least equal to (1 ) where (1 ) is a fixed number, positive and less than 1, the interval between T1and T2is a two-sided (1 ) confidence i
23、nterval for PD CEN/TR 15983:2010CEN/TR 15983:2010 (E) 6 EN 14181:2004, 3.5 2.6 CUSUM chart calculation procedure in which the amount of drift and change in precision is compared to the corresponding uncertainty components which are obtained during QAL1 EN 14181:2004, 3.6 2.7 drift monotonic change o
24、f the calibration function over stated period of unattended operation, which results in a change of the measured value EN 14181:2004, 3.7 NOTE This refers to a change in the response of the AMS to a determinant which does not change. 2.8 emission limit value ELV limit value related to the uncertaint
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CENTR159832010STATIONARYSOURCEEMISSIONSGUIDANCEONTHEAPPLICATIONOFEN141812004 固定 污染源 排放 EN141812004 应用

链接地址:http://www.mydoc123.com/p-592183.html