CEN TR 14819-1-2004 Safety recommendations for cableway installations designed to carry persons - Prevention and fight against fire - Part 1 Funicular railways in tunnels《索道 载人索道装置.pdf
《CEN TR 14819-1-2004 Safety recommendations for cableway installations designed to carry persons - Prevention and fight against fire - Part 1 Funicular railways in tunnels《索道 载人索道装置.pdf》由会员分享,可在线阅读,更多相关《CEN TR 14819-1-2004 Safety recommendations for cableway installations designed to carry persons - Prevention and fight against fire - Part 1 Funicular railways in tunnels《索道 载人索道装置.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、PUBLISHED DOCUMENT PD CEN/TR 14819-1:2004 Safety recommendations for cableway installations designed to carry persons Prevention and fight against fire Part 1: Funicular railways in tunnels ICS 13.220.20; 45.100 PD CEN/TR 14819-1:2004 This Published Document was published under the authority of the
2、Standards Policy and Strategy Committee on 10 November 2004 BSI 10 November 2004 ISBN 0 580 44716 2 National foreword This Published Document is the official English language version of CEN/TR 14819-1:2004. The UK participation in its preparation was entrusted to Technical Committee MCE/20, Aerial r
3、opeways, which has the responsibility to: A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue un
4、der the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpreta
5、tion, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the CEN/TR title page, pages 2 to 23 and a back cover. The BSI copy
6、right notice displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date CommentsTECHNICALREPORT RAPPORTTECHNIQUE TECHNISCHERBERICHT CEN/TR148191 September2004 ICS45.100;13.220.20 Englishversion Safetyrecommendationsforcablewayinstallatio
7、nsdesignedto carrypersonsPreventionandfightagainstfirePart1: Funicularrailwaysintunnels Recommandationsdescuritpourlesinstallations cblestransportantdespersonnesPrventionetlutte contrelesincendiesPartie1:Funiculairesentunnel SicherheitsempfehlungenfrSeilbahnenfrden PersonenverkehrBrandverhtungundbek
8、mpfungTeil 1:Tunnelstandseilbahnen ThisTechnicalReportwasapprovedbyCENon24February2004.IthasbeendrawnupbytheTechnicalCommitteeCEN/TC242. CENmembersarethenationalstandardsbodiesofAustria,Belgium,Cyprus,CzechRepublic,Denmark,Estonia,Finland,France, Germany,Greece,Hungary,Iceland,Ireland,Italy,Latvia,L
9、ithuania,Luxembourg,Malta,Netherlands,Norway,Poland,Portugal, Slovakia, Slovenia,Spain,Sweden,SwitzerlandandUnitedKingdom. EUROPEANCOMMITTEEFORSTANDARDIZATION COMITEUROPENDENORMALISATION EUROPISCHESKOMITEEFRNORMUNG ManagementCentre:ruedeStassart,36B1050Brussels 2004CEN Allrightsofexploitationinanyfo
10、rmandbyanymeansreserved worldwideforCENnationalMembers. Ref.No.CEN/TR148191:2004:ECEN/TR 14819-1:2004 (E) 2 Contents Page Foreword .4 Introduction.5 1 Scope6 2 Normative references.6 3 Terms and definitions 7 4 General recommendations.8 4.1 Application of the technical report8 4.2 Safety principles.
11、8 4.2.1 Hazard scenarios8 4.2.2 Safety measures.8 5 Basic recommendations 9 6 Recommendations concerning fire prevention and firefighting in the carriers 10 6.1 Materials .10 6.2 Electrical cabinets10 6.3 Cabling outside the electrical cabinets and lighting.10 6.4 Batteries10 6.5 Battery chargers.11
12、 6.6 Video equipment (camera, monitor) 11 6.7 Heating, air conditioning11 6.8 Electrical components outside cabinets which are energized during travel (dynamos, alternators, motors)11 6.9 Pantographs .11 6.10 Rail brake Retarder11 6.11 Hydraulic power plants and circuits Pressure vessels Refrigerant
13、s .11 6.12 Rotating parts (wheels, axles, bearings).12 6.13 Prohibition of smoking, open fires and the transportation of flammable materials12 6.14 Extinguishers and other means of firefighting .12 6.15 Dimensioning of the carriers .12 6.16 Recovery measures in the event of a fire on board the carri
14、er 12 6.17 Emergency exits from the carriers 13 7 Recommendations concerning fire prevention and firefighting in the tunnel.13 7.1 Tunnel materials.13 7.2 Fire Smoke from a station.13 7.3 Rails and overhead catenaries supplying auxiliary electrical energy to the carriers13 7.4 Lighting equipment 13
15、7.5 Transmission of electrical energy in the tunnel13 7.6 Remote communication cable between carrier and control point .14 7.7 Transportation of flammable liquid inside the tunnel.14 7.8 Spaces adjacent to the tunnel (outside stations)14 7.9 Communication device 14 8 Recommendations concerning fire
16、prevention and firefighting in stations 14 8.1 General14 8.2 Platform materials 15 8.3 Maintenance pit beneath carriers at the platform .15 8.4 Spaces adjacent to the platforms 15 8.5 Transmission of electrical energy .15 8.6 Contacts for recharging of the carrier batteries .16 CEN/TR 14819-1:2004 (
17、E) 3 8.7 Video equipment (camera, monitor) . 16 8.8 Dispensing machines for users and other platform furniture . 16 8.9 Prohibition of smoking, open fires and the transportation of flammable materials. 16 8.10 Extinguishers. 16 8.11 Smoke detection and clearing. 16 9 Recommendations concerning fire
18、prevention and firefighting in the machine room and the space for the electrical power system 16 9.1 Prevention 16 9.2 Limitation of spread of fire 17 10 Recommendations concerning fire prevention and firefighting in the electrical supply spaces 17 11 Recommendations concerning fire prevention and f
19、irefighting in the control room. 17 11.1 Civil engineering 17 11.2 Spaces adjacent to the control point 17 11.3 Electrical equipment 17 11.4 Video monitors 18 11.5 Space heating 18 11.6 Domestic utensils 18 11.7 Furniture 18 11.8 Putting safety devices out of service 18 11.9 Personnel. 18 12 Lightni
20、ng 18 13 Training of personnel 19 14 Maintenance. 19 Bibliography. 20 CEN/TR 14819-1:2004 (E) 4 Foreword This document (CEN/TR 14819-1:2004) has been prepared by Technical Committee CEN/TC 242 “Safety requirements for passenger transportation by rope”, the secretariat of which is held by AFNOR. CEN/
21、TR 14819 comprises the following parts presented under the general title of Prevention and fight against fire: Part 1: Funicular railways in tunnels Part 2: Other funicular railways and other installations This document forms part of the standards programme approved by the CEN Technical Board (CEN/B
22、T) on safety requirements for cableway installations designed to carry persons: 1 Safety requirements for cableway installations designed to carry persons - Terminology 2 Safety requirements for cableway installations designed to carry persons - General requirements 3 Safety requirements for cablewa
23、y installations designed to carry persons - Calculations 4 Safety requirements for cableway installations designed to carry persons - Ropes 5 Safety requirements for cableway installations designed to carry persons - Tensioning devices 6 Safety requirements for cableway installations designed to car
24、ry persons - Drive systems and other mechanical equipment 7 Safety requirements for cableway installations designed to carry persons - Carriers 8 Safety requirements for cableway installations designed to carry persons - Electrical equipment other than for drive systems 9 Safety requirements for cab
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CENTR1481912004SAFETYRECOMMENDATIONSFORCABLEWAYINSTALLATIONSDESIGNEDTOCARRYPERSONSPREVENTIONANDFIGHTAGAINSTFIREPART1FUNICULARRAILWAYSINTUNNELS

链接地址:http://www.mydoc123.com/p-592040.html